Hemoperfusion: technical aspects and state of the art
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Background: Blood purification through the removal of plasma solutes by adsorption to beads of charcoal or resins contained in a cartridge (hemoperfusion) has a long and imperfect history. Developments in production and coating technology, however, have recently increased the biocompatibility of sorbents and have spurred renewed interest in hemoperfusion. Methods: We performed a narrative assessment of the literature with focus on the technology, characteristics, and principles of hemoperfusion. We assessed publications in ex vivo, animal, and human studies. We synthesized such literature in a technical and state-of-the-art summary. Results: Early hemoperfusion studies were hampered by bioincompatibility. Recent technology, however, has improved its safety. Hemoperfusion has been used with positive effects in chronic dialysis and chronic liver disease. It has also demonstrated extraction of a variety of toxins and drugs during episodes of overdose. Trials with endotoxin binding polymyxin B have shown mixed results in septic shock and are under active investigation. The role of non-selective hemoperfusion in sepsis or inflammation remains. Although new technologies have made sorbents more biocompatible, the research agenda in the field remains vast. Conclusion: New sorbents markedly differ from those used in the past because of greater biocompatibility and safety. Initial studies of novel sorbent-based hemoperfusion show some promise in specific chronic conditions and some acute states. Systematic studies of novel sorbent-based hemoperfusion are now both necessary and justified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cruz, D. N., Antonelli, M., Fumagalli, R., Foltran, F., Brienza, N., Donati, A., Malcangi, V., Petrini, F., Volta, G., Bobbio Pallavicini, F. M., et al. (2009) · JAMA · doi:10.1001/jama.2009.856 · Cited by 832 · cited 1×
“It randomized 34 patients to polymyxin (PMX) B hemoperfusion and 30 to conventional care [53].”
BackgroundSelf-citationDellinger, R. P., Bagshaw, S. M., Antonelli, M., Foster, D. M., Klein, D. J., Marshall, J. C., Palevsky, P. M., Weisberg, L. S., Schorr, C. A., Trzeciak, S., et al. (2018) · JAMA · doi:10.1001/jama.2018.14618 · Cited by 502
The ABDOMIX Group, Payen, D. M., Guilhot, J., Launey, Y., Lukaszewicz, A. C., Kaaki, M., Veber, B., Pottecher, J., Joannes-Boyau, O., Martin-Lefevre, L., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3751-z · Cited by 407
Schädler, D., Pausch, C., Heise, D., Meier-Hellmann, A., Brederlau, J., Weiler, N., Marx, G., Putensen, C., Spies, C., Jörres, A., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0187015 · Cited by 367 · cited 1×
“A multicenter randomized trial compared Cytosorb® therapy with conventional care [62] in 100 ventilated patients with sepsis or septic shock and either acute lung injury or ARDS.”
MethodRonco, C., Tetta, C., Mariano, F., Wratten, M. L., Bonello, M., Bordoni, V., Cardona, X., Inguaggiato, P., Pilotto, L., D’Intini, V., et al. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07289.x · Cited by 356 · cited 1×
“Thus, any broad removal technique will remove more toxic than protective molecules [28].”
BackgroundSelf-citationEffectiveness of polymyxin B-immobilized fiber column in sepsis: a systematic review
Cruz, D. N., Perazella, M. A., Bellomo, R., de Cal, M., Polanco, N., Corradi, V., Lentini, P., Nalesso, F., Ueno, T., Ranieri, V. M., et al. (2007) · Critical Care · doi:10.1186/cc5780 · Cited by 347
Self-citationIn vitro comparison of the adsorption of inflammatory mediators by blood purification devices
Malard, B., Lambert, C., & Kellum, J. A. (2018) · Intensive Care Medicine Experimental · doi:10.1186/s40635-018-0177-2 · Cited by 273 · cited 1×
“Nonetheless, the concept of blood purification therapy is supported by multiple ex vivo studies [19–21] and experimental animal studies [22, 23].”
BackgroundKlein, D. J., Foster, D., Walker, P. M., Bagshaw, S. M., Mekonnen, H., & Antonelli, M. (2018) · Intensive Care Medicine · doi:10.1007/s00134-018-5463-7 · Cited by 249 · cited 1×
“However, a post hoc assessment of patients without extreme endotoxemia [56] found a survival advantage on time to event analysis.”
BackgroundSupady, A., Weber, E., Rieder, M., Lother, A., Niklaus, T., Zahn, T., Frech, F., Müller, S., Kuhl, M., Benk, C., et al. (2021) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(21)00177-6 · Cited by 206 · cited 5×
“In this regard, we recommend that a hemoperfusion registry be set up to collect data as in ECMO registries.”
MethodInfluentialBrouwer, W. P., Duran, S., Kuijper, M., & Ince, C. (2019) · Critical Care · doi:10.1186/s13054-019-2588-1 · Cited by 191
Cited by
Zarbock, A., Nadim, M. K., Pickkers, P., Gomez, H., Bell, S., Joannidis, M., Kashani, K., Koyner, J. L., Pannu, N., Meersch, M., et al. (2023) · Nature Reviews Nephrology · doi:10.1038/s41581-023-00683-3 · Cited by 767
Self-citation
Metadata
- Authors
- Ronco, C., & Bellomo, R.
- Venue
- Critical Care
- Published
- 2022-05-12
- Volume
- 26
- Issue
- 1
- Pages
- 135-135
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W4280555470
- Cited by
- 188
- References
- 45
- FWCI
- 19.30
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hemoperfusion: technical aspects and state of the art. https://app.cochat.ai/papers/10.1186/s13054-022-04009-w
- The paper
- Ronco, C., & Bellomo, R. (2022). Hemoperfusion: technical aspects and state of the art. Critical Care. https://doi.org/10.1186/s13054-022-04009-w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.