For avid glucose tumors, the SUV peak is the most reliable parameter for [18F]FDG-PET/CT quantification, regardless of acquisition time
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
BACKGROUND: This study is an assessment of the impact of acquisition times on SUV with [(18)F]FDG-PET/CT on healthy livers (reference organ with stable uptake over time) and on tumors. METHODS: One hundred six [(18)F]FDG-PET/CT were acquired in list mode over a single-bed position (livers (n = 48) or on tumors (n = 58)). Six independent datasets of different durations were reconstructed (from 1.5 to 10 min). SUVmax (hottest voxel), SUVpeak (maximum average SUV within a 1-cm(3) spherical volume), and SUVaverage were measured within a 3-cm-diameter volume of interest (VOI) in the right lobe of the liver. For [(18)F]FDG avid tumors (SUVmax ≥ 5), the SUVmax, SUVpeak, and SUV41% (isocontour threshold method) were computed. RESULTS: For tumors, SUVpeak values did not vary with acquisition time. SUVmax displayed significant differences between 1.5- and 5-10-min reconstruction times. SUV41% was the most time-dependent parameter. For the liver, the SUVaverage was the sole parameter that did not vary over time. CONCLUSIONS: For [(18)F]FDG avid tumors, with short acquisition times, i.e., with new generations of PET systems, the SUVpeak may be more robust than the SUVmax. The SUVaverage over a 3-cm-diameter VOI in the right lobe of the liver appears to be a good method for a robust and reproducible assessment of the hepatic metabolism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This is especially true for SUVmean and, to a lesser degree, for SUVpeak, which are both relatively stable even after reduction of acquisition time to 50% or less [76,77,78,79,80].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [80]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In contrast, SUVmax can vary substantially because this is, by definition, the outlier, which is most affected by increasing relative errors with declining count statistics [76,80].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [80]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777 · cited 9×
“For the liver, a 14-cm3 VOI was positioned on the right lobe of the liver on R10, as proposed in PERCIST [3].”
BackgroundMethodInfluentialFDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303 · cited 2×
“A threshold of 41 % was chosen following the EANM guidelines [10] and because the most common thresholding value chosen in the clinical setting is 40–43 % of the SUVmax.”
MethodQuantitation in Positron Emission Computed Tomography: 1. Effect of Object Size
Hoffman, E. J., Huang, S.-C., & Phelps, M. E. (1979) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197906000-00001 · Cited by 1,143 · cited 3×
“Moreover, for small lesions or during an effective treatment with a decrease in tumor size, when partial-volume effect may result in an underestimation of [18F]FDG uptake, SUVmax may be best suited as metabolic index than the other SUVs [12].”
BackgroundInfluentialStandards for PET Image Acquisition and Quantitative Data Analysis
Boellaard, R. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057182 · Cited by 902 · cited 1×
“5 versus R10) were observed for the same tumor in the same patient, which is obviously unacceptable for response-monitoring purposes, particularly when accumulated to other sources of bias [11, 21] and if a threshold value is applied to determine treatment response as with PERCIST criteria [3].”
(2004) · PubMed · Cited by 653
Lin, C., Itti, E., Haioun, C., Petegnief, Y., Luciani, A., Dupuis, J., Paone, G., Talbot, J.-N., Rahmouni, A., & Meignan, M. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.042093 · Cited by 394 · cited 2×
“In a clinical point of view, identification of a suitable SUV for response quantification requires clinical trials with patients’ clinical outcomes, and SUVmax demonstrated positive predictive values and accuracies for outcome prediction in lymphoma [1] as well as in solid tumors [13, 14].”
BackgroundWesterterp, M., Pruim, J., Oyen, W., Hoekstra, O., Paans, A., Visser, E., van Lanschot, J., Sloof, G., & Boellaard, R. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0224-1 · Cited by 294 · cited 1×
“SUVpeak has a larger volume compared to the single pixel value of SUVmax and thus should be less affected by image noise [4, 5, 16].”
BackgroundKrak, N. C., Boellaard, R., Hoekstra, O. S., Twisk, J. W. R., Hoekstra, C. J., & Lammertsma, A. A. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-004-1566-1 · Cited by 283 · cited 4×
“Because this VOI encompasses several pixels, SUVpeak is assumed to be less affected by image noise than SUVmax [4, 5] and then more reliable and * Correspondence: av.”
BackgroundMethodInfluentialNoise Considerations for PET Quantification Using Maximum and Peak Standardized Uptake Value
Lodge, M. A., Chaudhry, M. A., & Wahl, R. L. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.101733 · Cited by 226
Nahmias, C., & Wahl, L. M. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054239 · Cited by 200 · cited 2×
“Because this VOI encompasses several pixels, SUVpeak is assumed to be less affected by image noise than SUVmax [4, 5] and then more reliable and * Correspondence: av.”
Background
Cited by
Alberts, I., Hünermund, J.-N., Prenosil, G., Mingels, C., Bohn, K. P., Viscione, M., Sari, H., Vollnberg, B., Shi, K., Afshar-Oromieh, A., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05282-7 · Cited by 286
“Peak lesion activity and SUVpeak was used to evaluate target lesions, and this parameter has been shown to be less sensitive to acquisition time than SUVmax [15].”
MethodRadiomics in Oncological PET/CT: a Methodological Overview
Ha, S., Choi, H., Paeng, J. C., & Cheon, G. J. (2019) · Nuclear Medicine and Molecular Imaging · doi:10.1007/s13139-019-00571-4 · Cited by 138
Altazi, B. A., Zhang, G. G., Fernandez, D. C., Montejo, M. E., Hunt, D., Werner, J., Biagioli, M. C., & Moros, E. G. (2017) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12170 · Cited by 122
EANM practice guideline for quantitative SPECT-CT
Dickson, J. C., Armstrong, I. S., Gabiña, P. M., Denis-Bacelar, A. M., Krizsan, A. K., Gear, J. I., WYNGAERT, T. V. D., de Geus‐Oei, L., & Herrmann, K. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-06028-9 · Cited by 142
“SUVpeak is an alternative measure for quantitative SPECT, capturing the status of metabolically active features while mitigating image noise [14, 15].”
BackgroundEvolutionary dynamics at the tumor edge reveal metabolic imaging biomarkers
Jiménez-Sánchez, J., Bosque, J. J., Londoño, G. A. J., Molina-García, D., Martínez, Á., Pérez-Beteta, J., Ortega-Sabater, C., Martínez, A. F. H., Vicente, A. M. G., Calvo, G. F., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2018110118 · Cited by 71
“We could also have used SUVpeak (the maximum SUV appearing in the distribution when all of the voxels are averaged with their 26 neighbors), which is thought to be more stable and to better define an extended region of high uptake (38).”
MethodInfluences on PET Quantification and Interpretation
Rogasch, J. M. M., Hofheinz, F., van Heek, L., Voltin, C.-A., Boellaard, R., & Kobe, C. (2022) · Diagnostics · doi:10.3390/diagnostics12020451 · Cited by 57
Impact of the new ultra-high sensitivity mode in a long axial field-of-view PET/CT
Mingels, C., Weidner, S., Sari, H., Buesser, D., Zeimpekis, K., Shi, K., Alberts, I., & Rominger, A. (2023) · Annals of Nuclear Medicine · doi:10.1007/s12149-023-01827-y · Cited by 55
“Peak and maximum standardised uptake values (SUVpeak/max) were used to evaluate target lesion knowing that SUVpeak has been shown to be less susceptible for variation at different acquisition times than SUVmax [15].”
MethodAltazi, B. A., Fernandez, D. C., Zhang, G. G., Hawkins, S. H., Naqvi, S. M. H., Kim, Y., Hunt, D., Latifi, K., Biagioli, M. C., Venkat, P. S., et al. (2018) · Physica Medica · doi:10.1016/j.ejmp.2017.10.009 · Cited by 52
“2 cm in diameter to yield a ~1 cm3 sphere centered at each voxel within the tumor volume) as a potential robust alternative to SUVMAX due to its minimum variability over time and relative insensitivity to image noise [8,9].”
BackgroundAlberts, I., Prenosil, G., Mingels, C., Bohn, K. P., Viscione, M., Sari, H., Rominger, A., & Afshar‐Oromieh, A. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05438-5 · Cited by 48
Reproducibility of [18F]FDG PET/CT liver SUV as reference or normalisation factor
Zwezerijnen, G. J. C., Eertink, J. J., Ferrández, M. C., Wiegers, S. E., Burggraaff, C. N., Lugtenburg, P. J., Heymans, M. W., de Vet, H. C. W., Zijlstra, J. M., & Boellaard, R. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-05977-5 · Cited by 48
FDG PET/CT for Assessment of Immune Therapy: Opportunities and Understanding Pitfalls
Cho, S. Y., Huff, D. T., Jeraj, R., & Albertini, M. R. (2020) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2020.06.001 · Cited by 39
Ly, J., Minarik, D., Edenbrandt, L., Wollmer, P., & Trägårdh, E. (2019) · EJNMMI Research · doi:10.1186/s13550-019-0536-3 · Cited by 31
SUV variability in EARL-accredited conventional and digital PET
Koopman, D., Jager, P. L., Slump, C. H., Knollema, S., & van Dalen, J. A. (2019) · EJNMMI Research · doi:10.1186/s13550-019-0569-7 · Cited by 34
“SUVpeak was defined as the average SUV of a spherical 1 cm(3) volume-of-interest in the tumour-region with the highest uptake [11].”
BackgroundPark, M. J., Oh, J. S., Roh, J., Kim, J. S., Lee, J. H., Nam, S. Y., & Kim, S. Y. (2017) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000001515 · Cited by 30
“SUVpeakwas computed as an average SUVwithin a defined volume of interest containing the hottest pixel value.(24) For MTV calculations, the contouring margins of the primary tumor were delineated by using the SUV 2.”
Mohr, P., van Sluis, J., Providência, L., van Snick, J. H., Hooge, M. N. L., Willemsen, A. T. M., Glaudemans, A. W. J. M., Boellaard, R., Lammertsma, A. A., Brouwers, A. H., et al. (2023) · Journal of Nuclear Medicine · doi:10.2967/jnumed.123.265621 · Cited by 29
Evolution of heterotopic bone in fibrodysplasia ossificans progressiva: An [18F]NaF PET/CT study
Botman, E., Raijmakers, P. G. H. M., Yaqub, M. M., Teunissen, B. P., Netelenbos, J. C., Lubbers, W. D., Schwarte, L. A., Micha, D., Bravenboer, N., Schoenmaker, T., et al. (2019) · Bone · doi:10.1016/j.bone.2019.03.009 · Cited by 28
Ahmaddy, F., Burgard, C., Beyer, L., Koehler, V. F., Bartenstein, P., Fabritius, M. P., Geyer, T., Wenter, V., Ilhan, H., Spitzweg, C., et al. (2021) · Cancers · doi:10.3390/cancers13020317 · Cited by 28
“To date, SUVmax is the most commonly used semiquantitative PET-parameter due to its simple application but there are more and more studies suggesting the use of SUVpeak alternatively [38].”
MethodLu, Y., Houson, H. A., Gallegos, C., Mascioni, A., Jia, F., Aivazian, A., Song, P. N., Lynch, S. E., Napier, T. S., Mansur, A., et al. (2024) · Breast Cancer Research · doi:10.1186/s13058-024-01844-3 · Cited by 33
Tutino, F., Puccini, G., Linguanti, F., Puccini, B., Rigacci, L., Kovalchuk, S., Sciagrà, R., & Berti, V. (2020) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001324 · Cited by 24
Fledelius, J., Khalil, A., Hjorthaug, K., & Frøkiær, J. (2016) · EJNMMI Research · doi:10.1186/s13550-016-0223-6 · Cited by 24
“Furthermore, SULpeak has recently been shown to be independent of acquisition time [38], but is potentially slightly more observer dependent than SUVmax, especially in low uptake tumors.”
BackgroundDoes quantification have a role to play in the future of bone SPECT?
Ross, J. C., Vilić, D., Sanderson, T., Vöö, S. A., & Dickson, J. C. (2019) · European Journal of Hybrid Imaging · doi:10.1186/s41824-019-0054-6 · Cited by 23
“SUVmax and SUVpeak, however, should still be considered strong contenders for quantifying focal uptake (Suh et al. 2016).”
BackgroundAdvancements and Future Outlook of PET/CT-Guided Interventions
Dzaye, O. D. A., Cornélis, F., Kunin, H. S., & Sofocleous, C. T. (2023) · Techniques in vascular and interventional radiology · doi:10.1016/j.tvir.2023.100916 · Cited by 24
Zhang, L., Sun, H., Du, S., Xu, W., Xin, J., & Guo, Q. (2018) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000909 · Cited by 23
Kim, Y. I., Paeng, J. C., Park, Y. S., Cheon, G. J., Lee, D. S., Chung, J.-K., & Kang, K. W. (2018) · American Journal of Roentgenology · doi:10.2214/ajr.17.18916 · Cited by 20
Wang, T., Sun, H., Guo, Y., & Zou, L. (2019) · Molecular Imaging · doi:10.1177/1536012119856965 · Cited by 20
“SUVpeak can improve the accuracy and repeatability of measurements.(11) A high SUVpeak in early-stage cervical cancer can reflect more aggressive lesions, can help predict prognosis,(27) and is a prognostic parameter of poor survival outcomes in patients with oral cancer.”
BackgroundReinert, C. P., Gatidis, S., Sekler, J., Dittmann, H., Pfannenberg, C., la Fougère, C. J., Nikolaou, K., & Forschner, A. (2020) · Cancer Imaging · doi:10.1186/s40644-020-00322-1 · Cited by 19
“combined information about PET parameters and clinical factors showing that melanoma patients with high serum LDH in combination with elevated wholebody MTV had a worse prognosis than patients with a high serum LDH or an elevated MTV alone [25].”
BackgroundPET-CT in Clinical Adult Oncology: I. Hematologic Malignancies
Salem, A. E., Shah, H., Covington, M. F., Koppula, B. R., Fine, G., Wiggins, R. H., Hoffman, J. M., & Morton, K. A. (2022) · Cancers · doi:10.3390/cancers14235941 · Cited by 26
“Therefore, SUVmean may represent a better estimate of activity in blood pool and especially in liver, than SUVmax.”
BackgroundInfluentialMercieca, S., Belderbos, J. S. A., van Loon, J., Gilhuijs, K. G. A., Julyan, P. J., & van Herk, M. (2018) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2018.06.028 · Cited by 17
ELSayed, B. B., Alksas, A., Shehata, M., Mahmoud, A. H., Zaky, M. M., Alghandour, R., Abdelwahab, K. M., Abdelkhalek, M., Ghazal, M. A., Contractor, S. G., et al. (2023) · Cancers · doi:10.3390/cancers15215288 · Cited by 21
Costa, P. F., Jentzen, W., Süßelbeck, F., Fendler, W. P., Rischpler, C., Herrmann, K., Conti, M., Kersting, D., & Weber, M. (2021) · The Quarterly Journal of Nuclear Medicine and Molecular Imaging · doi:10.23736/s1824-4785.21.03300-8 · Cited by 15
Monsef, A., Ay, M. R., Sheikhzadeh, P., Geramifar, P., Rahmim, A., & Ghafarian, P. (2022) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001598 · Cited by 13
de Alencar, N. R. G., Machado, M. A. D., Mourato, F. A., de Oliveira, M. L., Moraes, T. F., Mattos, L. A. R., Chang, T. M., de Azevedo, C. R. A. S., & Brandão, S. C. S. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.1046551 · Cited by 14
“SUVpeak is reported as more robust and reproducible than SUVmax and SUVmean, although it is not widely disseminated in clinical practice (7).”
BackgroundMethodSong, Y., Meng, X., Cao, Z., Zhao, W., Zhang, Y., Guo, R., Zhou, X. H., Yang, Z. H., & Li, N. (2023) · EJNMMI Physics · doi:10.1186/s40658-023-00540-z · Cited by 13
PET and MRI based RT treatment planning: Handling uncertainties
Reynaert, N. (2019) · Cancer/Radiothérapie · doi:10.1016/j.canrad.2019.08.002 · Cited by 15
Lyra, V., Chatziioannou, S. N., & Kallergi, M. (2022) · Metabolites · doi:10.3390/metabo12030217 · Cited by 12
Mingels, C., Weissenrieder, L., Zeimpekis, K., Sari, H., Nardo, L., Caobelli, F., Alberts, I., Rominger, A., & Pyka, T. (2024) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-024-06646-5 · Cited by 13
Sun, Y., Deng, M., Gevaert, O., Aberle, M. R., Damink, S. W. M. O., van Dijk, D. P. J., & Rensen, S. S. (2024) · Clinical Nutrition · doi:10.1016/j.clnu.2024.05.040 · Cited by 15
Skipar, K., Hompland, T., Lund, K. V., Løndalen, A. M., Malinen, E., Kristensen, G. B., Lindemann, K. Y., Nakken, E. S., Bruheim, K., & Lyng, H. (2022) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2022.09.002 · Cited by 12
Gompelman, M., Tuinte, R. A. M., Aarntzen, E. H. J. G., Kouijzer, I. J. E., van Leerdam, E. J., Berrevoets, M. A. H., ten Oever, J., Bleeker‐Rovers, C. P., & Wanten, G. J. A. (2021) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2021.112296 · Cited by 12
Liu, E., Huang, J., Dong, H., Chen, Z., Liu, C., Xie, Q., Xu, W., Wang, S., & Liu, Z. (2021) · Journal of Nuclear Cardiology · doi:10.1007/s12350-021-02723-6 · Cited by 10
Novikov, M. (2019) · European Radiology Experimental · doi:10.1186/s41747-019-0124-3 · Cited by 10
Quak, E., Weyts, K., Jaudet, C., Prigent, A., Foucras, G., & Lasnon, C. (2023) · Frontiers in Medicine · doi:10.3389/fmed.2023.1137514 · Cited by 10
“8% of protocol_WeightDose and protocol_WeightDoseAI patients (18/22) (25) were not sufficiently measurable.”
BackgroundLiu, E., Lyu, Z., Yang, Y., Lv, Y., Zhao, Y., Zhang, X., Sun, T., Jiang, L., & Liu, Z. (2023) · EJNMMI Research · doi:10.1186/s13550-023-01015-z · Cited by 9
“5 min differed from those collected at 5 min [21].”
Whole-body PET image denoising for reduced acquisition time
Kruzhilov, I. S., Kudin, S., Vetoshkin, L., Sokolova, E., & Kokh, V. (2024) · Frontiers in Medicine · doi:10.3389/fmed.2024.1415058 · Cited by 13
Fluorodeoxyglucose-PET for Ablation Treatment Planning, Intraprocedural Monitoring, and Response
Kishore, S. A., Drabkin, M. J., & Sofocleous, C. T. (2019) · PET Clinics · doi:10.1016/j.cpet.2019.06.006 · Cited by 9
Prognostic value of pre-therapeutic FDG-PET radiomic analysis in gastro-esophageal junction cancer
Amrane, K., Thuillier, P., Bourhis, D., Meur, C. L., Quere, C., Leclere, J.-C., Ferec, M., Tallec, V. J.-L., Doucet, L., Alemany, P., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-31587-8 · Cited by 9
PET NEMA IQ Phantom dataset: image reconstruction settings for quantitative PET imaging
Vosoughi, H., Hajizadeh, M., Emami, F., Momennezhad, M., & Geramifar, P. (2021) · Data in Brief · doi:10.1016/j.dib.2021.107231 · Cited by 9
Govaerts, C. W., van Dijken, B. R. J., Stormezand, G. N., van der Weide, H. L., Wagemakers, M., Enting, R. H., & van der Hoorn, A. (2021) · British Journal of Radiology · doi:10.1259/bjr.20210275 · Cited by 8
Whole-body tumor burden in PET/CT expert review
dos Santos, D. F., Takahashi, M. E. S., Camacho, M., Lima, M., Amorim, B. J., ROHREN, E. M., & Etchebehere, E. (2022) · Clinical and Translational Imaging · doi:10.1007/s40336-022-00517-5 · Cited by 10
Mosleh‐Shirazi, M. A., Feshani, Z. N., Ghafarian, P., Alavi, M., Haddadi, G., & Ketabi, A. (2021) · Japanese Journal of Radiology · doi:10.1007/s11604-021-01112-w · Cited by 8
Yang, J., Zhu, S., Pang, F., Xu, M., Dong, Y., Hao, J., & Ma, X. (2018) · Contrast Media & Molecular Imaging · doi:10.1155/2018/8659826 · Cited by 7
Park, H. L., Lee, S.-W., Hong, J. H., Lee, J., Lee, A., Kwon, S. J., Park, S. Y., & Yoo, I. R. (2023) · Cancer Imaging · doi:10.1186/s40644-022-00519-6 · Cited by 6
Clinical Significance of Incidental Focal 18F-FDG Uptake in the Spinal Cord of Patients with Cancer
Lim, C. H., Hyun, S. H., Moon, S. H., Cho, Y. S., Choe, Y. S., Lee, K. H., Kim, B. T., & Choi, J. Y. (2017) · Nuclear Medicine and Molecular Imaging · doi:10.1007/s13139-016-0468-z · Cited by 6
Ghidaglia, J., Laurent, V., Sebagh, M., Pascale, A., Durand, E., Golse, N., & Besson, F. L. (2023) · Frontiers in Medicine · doi:10.3389/fmed.2023.1087957 · Cited by 6
Skórska, M., Piotrowski, T., & Ryczkowski, A. (2017) · British Journal of Radiology · doi:10.1259/bjr.20170019 · Cited by 6
McHugh, C. T., Garside, J. C., Barkes, J., Frank, J., Dragicevich, C. J., Yuan, H., & Branca, R. T. (2020) · EJNMMI Research · doi:10.1186/s13550-020-00726-x · Cited by 6
“SUVpeak represents the average uptake within an ROI centered around the local maximum, and it is less susceptible to image noise [31].”
Vicente, A. M. G., Pérez-Beteta, J., Amo‐Salas, M., Bosque, J. J., Noriega-Álvarez, E., Castrejón, Á. M. S., & Pérez‐García, V. M. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11206065 · Cited by 5
“In the present work, we used SUVpeak as a more reproducible, stable, and accurate metric than SUVmax [62,63].”
MethodAlRasheedi, M., Han, S., Thygesen, H. H., Neilson, M., Hendry, F., Alkarn, A. A., Maclay, J. D., & Leung, H. Y. (2023) · Diagnostics · doi:10.3390/diagnostics13071209 · Cited by 10
“SUVmax was obtained from the most FDG-avid voxel within a region of interest, signifying maximum standardised uptake value [16].”
MethodGenc, M., Yıldırım, N., Coskun, N., Özdemir, E., & Türkölmez, Ş. (2023) · Revista Española de Medicina Nuclear e Imagen Molecular (English Edition) · doi:10.1016/j.remnie.2023.07.006 · Cited by 6
Chuang, P.-J., Wang, H.-P., Lin, Y.-J., Chen, C., Tien, Y., Hsieh, M., Yang, S., Yen, R., Ko, C., Wu, Y., et al. (2021) · European Radiology · doi:10.1007/s00330-021-07923-9 · Cited by 5
Chen, X., Ma, T., Sun, H., Li, X., & Gao, S. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.659313 · Cited by 10
Impact of Tissue Classification in MRI-Guided Attenuation Correction on Whole-Body Patlak PET/MRI
Zhuang, M., Karakatsanis, N. A., Dierckx, R., & Zaidi, H. (2019) · Molecular Imaging and Biology · doi:10.1007/s11307-019-01338-1 · Cited by 5
“The ROIpeak metric has been recently recommended as a more robust alternative to ROImax [39].”
MethodInfluentialPET Parameters are Useful in Predicting Endometrial Cancer Risk Classes and Prognosis
Budak, A., Beyan, E., İnan, A. H., Kanmaz, A. G., Aldemir, O. S., Oral, A., Yazıcı, B., Akgün, A., & Özeren, M. (2020) · Nuklearmedizin - NuclearMedicine · doi:10.1055/a-1267-8976 · Cited by 4
Zhang, Y., Hu, Y., Zhao, S., & Huang, R. (2024) · Clinical Medicine Insights Oncology · doi:10.1177/11795549231225419 · Cited by 9
Evaluation of Malignancy Risk of Ampullary Tumors Detected by Endoscopy Using 2-[18F]FDG PET/CT
Chuang, P.-J., Wang, H., Tien, Y., Chin, W., Hsieh, M., Chen, C., Hong, T., Ko, C., Wu, Y., & Cheng, M. (2024) · Korean Journal of Radiology · doi:10.3348/kjr.2023.0295 · Cited by 5
“Tumor volume was autosegmented at 40% of the maximum SUV (SUVmax), with manual corrections made in reference to low-dose CT to exclude physiological bowel or renal activity when needed [17,31].”
Ou, W. C., Jennings, J. W., Northrup, B. E., Dettorre, G. M., Winkler, W. L., Imaoka, R., Velde, T. L. V., & Siegel, B. A. (2024) · Skeletal Radiology · doi:10.1007/s00256-024-04855-5 · Cited by 4
New full‐counts phase‐matched data‐driven gated (DDG) PET/CT
Sun, P., Thomas, M. A., Luo, D., & Pan, T. (2024) · Medical Physics · doi:10.1002/mp.17097 · Cited by 3
Choi, S., Kim, Y.-I., Lee, G. D., Choi, S., Kim, H. R., Kim, Y., Kim, D. K., Park, S.-I., & Ryu, J. (2022) · Medicine · doi:10.1097/md.0000000000029867 · Cited by 4
“[28] Therefore, SUVpeak has been recommended as an alternative to SUVmax.”
BackgroundInfluentialНиколаева, Е. А., Krylov, A. S., Ryzhkov, A. D., Гелиашвили, Т. М., & Пронин, А. И. (2022) · Journal of oncology diagnostic radiology and radiotherapy · doi:10.37174/2587-7593-2022-5-3-29-42 · Cited by 3
Role of Novel Quantitative Imaging Techniques in Hematological Malignancies
Parghane, R. V., & Basu, S. K. (2024) · PET Clinics · doi:10.1016/j.cpet.2024.05.008 · Cited by 3
Leontyev, A. V., Рубцова, Н. А., Khalimon, A. I., Antonevskaya, T. L., Khamadeeva, G. F., Кулиев, М. Т., Валерьевна, Л. А., Pylova, I. V., Lazutina, T. N., Kostin, A. A., et al. (2020) · Russian Electronic Journal of Radiology · doi:10.21569/2222-7415-2020-10-1-191-205 · Cited by 2
Yamashita, K., Miyaji, N., Motegi, K., Terauchi, T., & Ito, S. (2021) · Research Square · doi:10.21203/rs.3.rs-877512/v1 · Cited by 5
Treatment Response Evaluation in Necrotizing Otitis Externa Using 18F-FDG-PET Imaging
Jansen, R. W., Kemp, P., Wiegers, S. E., de Graaf, P., van Schie, A., Martens, R. M., Boellaard, R., Zwezerijnen, G. J. C., & Goderie, T. P. M. (2025) · Otology & Neurotology · doi:10.1097/mao.0000000000004402 · Cited by 2
Bosque, J. J., Molina-García, D., Pérez-Beteta, J., Vicente, A. M. G., & Pérez‐García, V. M. (2026) · Annals of Nuclear Medicine · doi:10.1007/s12149-025-02138-0 · Cited by 3
Diagnostic value of 18F‑FDG PET/CT and MRI for intraspinal lesions: A comparative study
Zheng, F., Xiao, W., Shuaishuai, W., Wang, T., & Zou, L. (2021) · Medicine International · doi:10.3892/mi.2021.23 · Cited by 2
“The TLG was calculated as follows: TLG=SUVmean x MTV (cm3) (6), with SUVmax >2.”
MethodDomachevsky, L., Bernstine, H., Nidam, M., Stein, D. J., Goldberg, N., Stern, D., Abadi‐Korek, I., & Groshar, D. (2017) · Contrast Media & Molecular Imaging · doi:10.1155/2017/8639731 · Cited by 2
Mitsumoto, T., Minamimoto, R., Sunaoka, F., Kishimoto, S., Inoue, K., & Fukushi, M. (2019) · British Journal of Radiology · doi:10.1259/bjr.20180233 · Cited by 2
Efficacy of Single Energy Metal Artifact Reduction (SEMAR) for Head and Neck Cancer
Oshima, T., Tsuchiya, J., & Tateishi, U. (2019) · Institutional Repositories DataBase (IRDB) · doi:10.11480/jmds.660401 · Cited by 2
Centroid to SUVpeak distance is a prognostic PET biomarker in high-grade gliomaPreprint
Bosque, J. J., Molina-García, D., Pérez-Beteta, J., Vicente, A. G., & Pérez-García, V. M. (2025) · medRxiv · doi:10.1101/2025.08.22.25334230 · Cited by 1
“Therefore, the process of filtering needed to compute the SUVpeak might actually help better identify the right location of the activity hotspot ( 31 – 33 ).”
April, G., Bruycker, J. J. D., Decaluwe, H., Haddad, É., Lambert, R., & Turpin, S. (2022) · Annals of Nuclear Medicine · doi:10.1007/s12149-022-01748-2 · Cited by 4
“, the maximum average SUV within a 1-cm3 spherical volume has been proposed as a more reliable parameter [11].”
Inomata, T., Sato, K., Ibaraki, M., Kominami, M., Shinohara, Y., Kinoshita, F., Yamamoto, H., Kato, M., Kinoshita, T., & Chida, K. (2025) · Applied Sciences · doi:10.3390/app152212292 · Cited by 1
Zhang, Y., Xu, S., & Hu, Y. (2026) · BMC Cancer · doi:10.1186/s12885-026-15589-z · Cited by 1
“SUVs: SUVmax (maximum SUV), SUVmean (mean SUV), and SUVpeak (peak SUV, mean within a small, fixed-size VOI centered on the hottest pixel) [30, 31].”
Impact of local tumor-to-background uptake ratio on PET metabolic response assessment
Mehrara, E., Mohamed, M., Van-Essen, M., & Urdaneta, J. L. (2025) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaf145 · Cited by 1
“In addition, SUV peak is less affected by noise level than SUV max because this VOI comprises several pixels, making it less sensitive to random variations in the image data and a more robust and reliable measure [16].”
Afzelius, P., Morsing, M. K., Nielsen, O. L., Alstrup, A., Jensen, S. B., & Jødal, L. (2022) · Molecules · doi:10.3390/molecules27092792 · Cited by 1
“In the right–left pairs of superficial popliteal lymph nodes, however, there were no significant differences of [18F]FDG SUVmax in the nodes in the right and left hind limbs (Table 3).”
MethodInfluentialSong, C., Lee, J. J., Lee, S., Park, J., Kim, D., Suh, D., Kim, J.-H., Kim, Y., & Kim, J.-H. (2023) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001741 · Cited by 1
FDG uptake of pulmonary lesions in synchronous primary lung cancers and lung metastases
Karpinski, S., Bimani, Z. A., Dobson, J. L., & Zeng, W. (2024) · Research in Diagnostic and Interventional Imaging · doi:10.1016/j.redii.2024.100041 · Cited by 1
“SUV peak (maximum average SUV within a 1 cm 3 spherical volume) has often been used in research studies and was considered to be a reliable parameter for FDG quanti fi cation [26].”
MethodZhang, Y., Hu, Y., Zhao, S., & Xu, S. (2024) · Abdominal Radiology · doi:10.1007/s00261-024-04226-7 · Cited by 1
Yudistiro, R., Heryanto, Y. D., Kodaira, S., Higuchi, T., Arisaka, Y., Tokue, A., Taketomi-Takahashi, A., Tsukamoto, N., Yokohama, A., Handa, H., et al. (2018) · The Kitakanto Medical Journal · doi:10.2974/kmj.68.151
Szumowski, P., Szklarzewski, A., Żukowski, Ł., Abdelrazek, S., Mojsak, M. N., Porębska, K., Sierko, E., & Myśliwiec, J. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10071430
Ms, T., & Чипига, Л. А. (2021) · Современные технологии в медицине · doi:10.17691/stm2021.13.3.02
Imelda, J., & Paulraj, R. (2002) · Eprints@CMFRI Open Access Institutional Repository (Central Marine Fisheries Research Institute)
Optimization of SUV with Changing the Dose Amount in F18-FDG PET/CT of Pediatric Lymphoma Patients
Gülaldı, N., Çağdaş, B., & Görtan, F. A. (2022) · Current Radiopharmaceuticals · doi:10.2174/1874471016666221118114726
Genc, M., Yıldırım, N., Coskun, N., Özdemir, E., & Türkölmez, Ş. (2023) · Revista Española de Medicina Nuclear e Imagen Molecular · doi:10.1016/j.remn.2023.07.002
Yang, R., Xie, Y., Cai, D., Lin, Y., Yu, H., Zheng, Z., He, Y., & Shi, H. (2025) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000002073
Liu, E., Lyu, Z., Yang, Y., Lv, Y., Zhao, Y., Zhang, X., Sun, T., Jiang, L., & Liu, Z. (2023) · Figshare · doi:10.6084/m9.figshare.23658239
McHugh, C. T., Garside, J. C., Barkes, J., Frank, J., Dragicevich, C. J., Yuan, H., & Branca, R. T. (2020) · Figshare · doi:10.6084/m9.figshare.13204577
Liu, E., Lyu, Z., Yang, Y., Lv, Y., Zhao, Y., Zhang, X., Sun, T., Jiang, L., & Liu, Z. (2023) · Figshare · doi:10.6084/m9.figshare.23658245
Liu, E., Lyu, Z., Yang, Y., Lv, Y., Zhao, Y., Zhang, X., Sun, T., Jiang, L., & Liu, Z. (2023) · Figshare · doi:10.6084/m9.figshare.23658248
Lü, Y., Houson, H. A., Gallegos, C., Mascioni, A., Jia, F., Aivazian, A., Song, P. N., Lynch, S. E., Napier, T. S., Mansur, A., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26103786
Metadata
- Authors
- Sher, A., Lacoeuille, F., Fosse, P., Vervueren, L., Cahouet-Vannier, A., Dabli, D., Bouchet, F., & Couturier, O.
- Affiliations
- Centre Hospitalier Universitaire d'Angers (FR)
- Inserm (FR)
- Corresponding author
- Sher, Avigaëlle
- Venue
- EJNMMI Research
- Published
- 2016-03-05
- Volume
- 6
- Issue
- 1
- Pages
- 21-21
- ISSN
- 2191-219X (ISSN-L)
- PMC
- PMC4779086
- OpenAlex
- W2292171573
- Cited by
- 111
- References
- 24
- Citations by year
- 2026: 6 · 2025: 5 · 2024: 13 · 2023: 23 · 2022: 15 · 2021: 16 · 2020: 8 · 2019: 12 · 2018: 6 · 2017: 5 · 2016: 1
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- EJNMMI Research (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
- Keywords
- 18F-FDG PET/CT, SUVpeak, SUVmax, acquisition time, list-mode acquisition, liver SUV, tumor quantification, hepatic glucose metabolism
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.