For avid glucose tumors, the SUV peak is the most reliable parameter for [18F]FDG-PET/CT quantification, regardless of acquisition time
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
BACKGROUND: This study is an assessment of the impact of acquisition times on SUV with [(18)F]FDG-PET/CT on healthy livers (reference organ with stable uptake over time) and on tumors. METHODS: One hundred six [(18)F]FDG-PET/CT were acquired in list mode over a single-bed position (livers (n = 48) or on tumors (n = 58)). Six independent datasets of different durations were reconstructed (from 1.5 to 10 min). SUVmax (hottest voxel), SUVpeak (maximum average SUV within a 1-cm(3) spherical volume), and SUVaverage were measured within a 3-cm-diameter volume of interest (VOI) in the right lobe of the liver. For [(18)F]FDG avid tumors (SUVmax ≥ 5), the SUVmax, SUVpeak, and SUV41% (isocontour threshold method) were computed. RESULTS: For tumors, SUVpeak values did not vary with acquisition time. SUVmax displayed significant differences between 1.5- and 5-10-min reconstruction times. SUV41% was the most time-dependent parameter. For the liver, the SUVaverage was the sole parameter that did not vary over time. CONCLUSIONS: For [(18)F]FDG avid tumors, with short acquisition times, i.e., with new generations of PET systems, the SUVpeak may be more robust than the SUVmax. The SUVaverage over a 3-cm-diameter VOI in the right lobe of the liver appears to be a good method for a robust and reproducible assessment of the hepatic metabolism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This is especially true for SUVmean and, to a lesser degree, for SUVpeak, which are both relatively stable even after reduction of acquisition time to 50% or less [76,77,78,79,80].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [80]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In contrast, SUVmax can vary substantially because this is, by definition, the outlier, which is most affected by increasing relative errors with declining count statistics [76,80].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [80]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777 · cited 9×
“For the liver, a 14-cm3 VOI was positioned on the right lobe of the liver on R10, as proposed in PERCIST [3].”
BackgroundMethodInfluentialFDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303 · cited 2×
“A threshold of 41 % was chosen following the EANM guidelines [10] and because the most common thresholding value chosen in the clinical setting is 40–43 % of the SUVmax.”
MethodQuantitation in Positron Emission Computed Tomography: 1. Effect of Object Size
Hoffman, E. J., Huang, S.-C., & Phelps, M. E. (1979) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197906000-00001 · Cited by 1,143 · cited 3×
“Moreover, for small lesions or during an effective treatment with a decrease in tumor size, when partial-volume effect may result in an underestimation of [18F]FDG uptake, SUVmax may be best suited as metabolic index than the other SUVs [12].”
BackgroundInfluentialStandards for PET Image Acquisition and Quantitative Data Analysis
Boellaard, R. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057182 · Cited by 902 · cited 1×
“5 versus R10) were observed for the same tumor in the same patient, which is obviously unacceptable for response-monitoring purposes, particularly when accumulated to other sources of bias [11, 21] and if a threshold value is applied to determine treatment response as with PERCIST criteria [3].”
(2004) · PubMed · Cited by 653
Lin, C., Itti, E., Haioun, C., Petegnief, Y., Luciani, A., Dupuis, J., Paone, G., Talbot, J.-N., Rahmouni, A., & Meignan, M. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.042093 · Cited by 394 · cited 2×
“In a clinical point of view, identification of a suitable SUV for response quantification requires clinical trials with patients’ clinical outcomes, and SUVmax demonstrated positive predictive values and accuracies for outcome prediction in lymphoma [1] as well as in solid tumors [13, 14].”
BackgroundWesterterp, M., Pruim, J., Oyen, W., Hoekstra, O., Paans, A., Visser, E., van Lanschot, J., Sloof, G., & Boellaard, R. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0224-1 · Cited by 294 · cited 1×
“SUVpeak has a larger volume compared to the single pixel value of SUVmax and thus should be less affected by image noise [4, 5, 16].”
BackgroundKrak, N. C., Boellaard, R., Hoekstra, O. S., Twisk, J. W. R., Hoekstra, C. J., & Lammertsma, A. A. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-004-1566-1 · Cited by 283 · cited 4×
“Because this VOI encompasses several pixels, SUVpeak is assumed to be less affected by image noise than SUVmax [4, 5] and then more reliable and * Correspondence: av.”
BackgroundMethodInfluentialNoise Considerations for PET Quantification Using Maximum and Peak Standardized Uptake Value
Lodge, M. A., Chaudhry, M. A., & Wahl, R. L. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.101733 · Cited by 226
Nahmias, C., & Wahl, L. M. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054239 · Cited by 200 · cited 2×
“Because this VOI encompasses several pixels, SUVpeak is assumed to be less affected by image noise than SUVmax [4, 5] and then more reliable and * Correspondence: av.”
BackgroundImpact of the Definition of Peak Standardized Uptake Value on Quantification of Treatment Response
Vanderhoek, M., Perlman, S. B., & Jeraj, R. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.093443 · Cited by 188 · cited 2×
“The major drawback of SUVpeak is that its associated volume of interest (VOIpeak) is not uniquely defined, leading to a few dozen of SUVpeak definitions, differing in the shape, size, and location of the VOIpeak [6].”
BackgroundArmstrong, I. S., Kelly, M. D., Williams, H. A., & Matthews, J. C. (2014) · EJNMMI Physics · doi:10.1186/s40658-014-0099-3 · Cited by 84 · cited 1×
“Furthermore, point spread function (PSF) reconstruction, also available in new generations of PET systems, is known not only to improve sensitivity but also to overestimate SUV [8, 9].”
BackgroundEarly assessment of treatment response in patients with AML using [18F]FLT PET imaging
Vanderhoek, M., Juckett, M., Perlman, S. B., Nickles, R. J., & Jeraj, R. (2010) · Leukemia Research · doi:10.1016/j.leukres.2010.06.010 · Cited by 74 · cited 1×
“Theses inaccuracies may be more pronounced in case of tumor heterogeneity that moreover may change during the course of treatment [15].”
BackgroundLasnon, C., Hicks, R. J., Beauregard, J.-M., Milner, A., Paciencia, M., Guizard, A.-V., Bardet, S., Gervais, R., Lemoel, G., Zalcman, G., et al. (2012) · Clinical Nuclear Medicine · doi:10.1097/rlu.0b013e318251e3d1 · Cited by 65 · cited 2×
“Furthermore, point spread function (PSF) reconstruction, also available in new generations of PET systems, is known not only to improve sensitivity but also to overestimate SUV [8, 9].”
BackgroundMurray, I., Kalemis, A., Glennon, J., Hasan, S., Quraishi, S., Beyer, T., & Avril, N. E. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1466-5 · Cited by 60 · cited 1×
“chines (positron emission tomography scanner/X-ray computed tomography scanner) improves signal-tonoise ratio, spatial resolution, and lesion detectability, theoretically allowing reduced injected activity (and thus radiation exposure) and/or acquisition time [7].”
BackgroundCharacterization of the uptake of 16α-([18F]fluoro)-17β-estradiol in DMBA-induced mammary tumors
Mathias, C. J., Welch, M. J., Katzenellenbogen, J. A., Brodack, J. W., Kilbourn, M. R., Carlson, K. E., & Kiesewetter, D. O. (1987) · International Journal of Radiation Applications and Instrumentation Part B Nuclear Medicine and Biology · doi:10.1016/0883-2897(87)90156-5 · Cited by 51
Liver SULmeanat FDG PET/CT: Interreader Agreement and Impact of Placement of Volume of Interest
Maya, V., Mercier, G., Hao, F., Ashish, M., & Subramaniam, R. M. (2013) · Radiology · doi:10.1148/radiol.12121385 · Cited by 32 · cited 1×
“However, a recent study found an excellent inter-observer agreement and no significant difference whether the VOI is placed in the upper part, the portal level, or at the bottom of the right liver lobe [23].”
BackgroundHachemi, M., Couturier, O., Vervueren, L., Fosse, P., Lacœuille, F., Urban, T., & Hureaux, J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0087629 · Cited by 29 · cited 1×
“In a clinical point of view, identification of a suitable SUV for response quantification requires clinical trials with patients’ clinical outcomes, and SUVmax demonstrated positive predictive values and accuracies for outcome prediction in lymphoma [1] as well as in solid tumors [13, 14].”
BackgroundSelf-citationThe Impact of Acquisition Time on Image Quality in Whole-Body 18F-FDG PET/CT for Cancer Staging
Hausmann, D., Dinter, D. J., Sadick, M., Brade, J., Schoenberg, S. O., & Busing, K. (2012) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.112.103291 · Cited by 21
Kremer, R., Peysakhovich, Y., Faber, D. L., Guralnik, L., Kagna, O., Nir, R., & Bar‐Shalom, R. (2015) · Annals of Nuclear Medicine · doi:10.1007/s12149-015-1038-7 · Cited by 21 · cited 1×
“In a clinical point of view, identification of a suitable SUV for response quantification requires clinical trials with patients’ clinical outcomes, and SUVmax demonstrated positive predictive values and accuracies for outcome prediction in lymphoma [1] as well as in solid tumors [13, 14].”
BackgroundInvestigation of 18F-FDG 3D mode PET image quality versus acquisition time
Brown, C., Dempsey, M.-F., Gillen, G., & Elliott, A. T. (2010) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3283355c5d · Cited by 18 · cited 1×
“[17] investigated the effect of varying acquisition times on phantom and patient Table 3 Maximal individual SUV fluctuations (Δmax) compared to the reference SUV at 10 min”
BackgroundBouchet, F., Geworski, L., Knoop, B. O., Ferrer, L., Berriolo-Riedinger, A., Millardet, C., Fourcade, M., Martineau, A., Belly-Poinsignon, A., Djoumessi, F., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0058152 · Cited by 16 · cited 2×
“Considering a maximum fluctuation of 10 % as an acceptable level of variation for tumor SUV [11], the number of patients with tumor SUV fluctuations >10 % (compared to R10) was noted.”
BackgroundSelf-citationGoethals, I., D’Asseler, Y., Dobbeleir, A. A., Deblaere, K., & Ham, H. (2010) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e328334fbfd · Cited by 10 · cited 1×
“for images with scan times below 3 min [19].”
BackgroundGordien, P., Morlière, C., Bordenave, L., & Hindié, E. (2014) · Médecine Nucléaire · doi:10.1016/j.mednuc.2014.01.004 · Cited by 3 · cited 1×
“[24], who showed a larger dispersion of values and a higher variance for hepatic SUVmax compared to hepatic SUVaverage.”
Background
Cited by
Alberts, I., Hünermund, J.-N., Prenosil, G., Mingels, C., Bohn, K. P., Viscione, M., Sari, H., Vollnberg, B., Shi, K., Afshar-Oromieh, A., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05282-7 · Cited by 286
“Peak lesion activity and SUVpeak was used to evaluate target lesions, and this parameter has been shown to be less sensitive to acquisition time than SUVmax [15].”
MethodRadiomics in Oncological PET/CT: a Methodological Overview
Ha, S., Choi, H., Paeng, J. C., & Cheon, G. J. (2019) · Nuclear Medicine and Molecular Imaging · doi:10.1007/s13139-019-00571-4 · Cited by 138
Altazi, B. A., Zhang, G. G., Fernandez, D. C., Montejo, M. E., Hunt, D., Werner, J., Biagioli, M. C., & Moros, E. G. (2017) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12170 · Cited by 122
EANM practice guideline for quantitative SPECT-CT
Dickson, J. C., Armstrong, I. S., Gabiña, P. M., Denis-Bacelar, A. M., Krizsan, A. K., Gear, J. I., WYNGAERT, T. V. D., de Geus‐Oei, L., & Herrmann, K. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-06028-9 · Cited by 142
“SUVpeak is an alternative measure for quantitative SPECT, capturing the status of metabolically active features while mitigating image noise [14, 15].”
BackgroundEvolutionary dynamics at the tumor edge reveal metabolic imaging biomarkers
Jiménez-Sánchez, J., Bosque, J. J., Londoño, G. A. J., Molina-García, D., Martínez, Á., Pérez-Beteta, J., Ortega-Sabater, C., Martínez, A. F. H., Vicente, A. M. G., Calvo, G. F., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2018110118 · Cited by 71
“We could also have used SUVpeak (the maximum SUV appearing in the distribution when all of the voxels are averaged with their 26 neighbors), which is thought to be more stable and to better define an extended region of high uptake (38).”
Method
Metadata
- Authors
- Sher, A., Lacoeuille, F., Fosse, P., Vervueren, L., Cahouet-Vannier, A., Dabli, D., Bouchet, F., & Couturier, O.
- Affiliations
- Centre Hospitalier Universitaire d'Angers (FR)
- Inserm (FR)
- Corresponding author
- Sher, Avigaëlle
- Venue
- EJNMMI Research
- Published
- 2016-03-05
- Volume
- 6
- Issue
- 1
- Pages
- 21-21
- ISSN
- 2191-219X (ISSN-L)
- PMC
- PMC4779086
- OpenAlex
- W2292171573
- Cited by
- 111
- References
- 24
- Citations by year
- 2026: 6 · 2025: 5 · 2024: 13 · 2023: 23 · 2022: 15 · 2021: 16 · 2020: 8 · 2019: 12 · 2018: 6 · 2017: 5 · 2016: 1
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- EJNMMI Research (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
- Keywords
- 18F-FDG PET/CT, SUVpeak, SUVmax, acquisition time, list-mode acquisition, liver SUV, tumor quantification, hepatic glucose metabolism
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.