Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Feasibility of equivalent performance of 3D TOF [18F]-FDG PET/CT with reduced acquisition time using clinical and semiquantitative parameters

Open access

Abstract

Background: High-performance time-of-flight (TOF) positron emission tomography (PET) systems have the capability for rapid data acquisition while preserving diagnostic image quality. However, determining a reliable and clinically applicable cut-off of the acquisition time plays an important role in routine practice. This study aimed to assess the diagnostic equivalence of short acquisition time of 57 with routine 75 seconds per bed position (s/BP) of [18 F]-fluoro-deoxy-glucose (FDG) PET. Phantom studies applying EARL criteria suggested the feasibility of shortened acquisition time in routine clinical imaging by 3D TOF PET/CT scanners. Ninety-six patients with melanoma, lung or head and neck cancer underwent a standard whole-body, skull base-to-thigh or vertex-to-thigh [18 F]-FDG PET/CT examination using the 3D TOF Ingenuity TF PET/CT system (Philips, Cleveland, OH). The [18 F]-FDG activity applied was equal to 4MBq per kg body weight. Retrospectively, PET list-mode data were used to calculate a second PET study per patient with a reduced acquisition time of 57 s instead of routine 75 s/BP. PET/CT data were reconstructed using a 3D OSEM TOF algorithm. Blinded patient data were analysed by two nuclear medicine physicians. The number of [18 F]-FDG-avid lesions per body region (head&neck, thorax, abdomen, bone, extremity) and image quality (grade 1–5) were evaluated. Semiquantitative analyses were performed by standardized uptake value (SUV) measurements using 3D volume of interests (VOI). The visual and semiquantitative diagnostic equivalence of 214 [18 F]-FDG-avid lesions were analysed in the routine standard (75 s/BP) as well as the calculated PET/CT studies with short acquisition time. Statistical analyses were performed by equivalence testing and Bland–Altman plots. Results: Lesion detection rate per patient’s body region agreed in > 98% comparing 57 s/BP and 75 s/BP datasets. Overall image quality was determined as equal or superior to 75 s in 80% and 69%, respectively. In the semiquantitative lesion-based analyses, a significant equivalence was found between the 75 s/BP and 57 s/BP PET/CT images both for SUV max (p = 0.004) and SUV mean (p = 0.003). Conclusion: The results of this study demonstrate significant clinical and semiquantitative equivalence between short acquisition time of 57 s/BP and standard 75 s/BP 3D TOF [18 F]-FDG PET/CT scanning, which may improve the patient’s workflow in routine practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13550-021-00784-9

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 MIP, fused axial and coronal PET/CT images (from left to right) with 75 s (upper row )and 57 s (lower row) PET acquisition time per bed position of a 71-year-old female patient with 65 kg bw suffering from lung cancer—no significant difference in image quality, lesion detectability and quantification
Fig. 1 MIP, fused axial and coronal PET/CT images (from left to right) with 75 s (upper row )and 57 s (lower row) PET acquisition time per bed position of a 71-year-old female patient with 65 kg bw suffering from lung cancer—no significant difference in image quality, lesion detectability and quantificationCC BY · PubMed Central
Fig. 2 MIP, fused axial and coronal PET/CT images (from left to right) with 75 s (upper row )and 57 s (lower row) PET acquisition time per bed position of a 63-year-old male patient with 94 kg bw suffering from melanoma—no significant difference in image quality, lesion detectability and quantification
Fig. 2 MIP, fused axial and coronal PET/CT images (from left to right) with 75 s (upper row )and 57 s (lower row) PET acquisition time per bed position of a 63-year-old male patient with 94 kg bw suffering from melanoma—no significant difference in image quality, lesion detectability and quantificationCC BY · PubMed Central
Fig. 3 MIP, fused axial and coronal PET/CT images (from left to right) with 75 s (upper row )and 57 s (lower row) PET acquisition time per bed position of a 57-year-old male patient with 105 kg bw suffering from head & neck cancer—no significant difference in image quality, lesion detectability and quantification
Fig. 3 MIP, fused axial and coronal PET/CT images (from left to right) with 75 s (upper row )and 57 s (lower row) PET acquisition time per bed position of a 57-year-old male patient with 105 kg bw suffering from head & neck cancer—no significant difference in image quality, lesion detectability and quantificationCC BY · PubMed Central
Fig. 4 Comparison of SUVmax 75 s and 57 s PET/CT datasets and SUVmean 75 s and 57 s PET/CT images of 214 [18F]-FDG-avid lesions by performing the TOST equivalence test [20]
Fig. 4 Comparison of SUVmax 75 s and 57 s PET/CT datasets and SUVmean 75 s and 57 s PET/CT images of 214 [18F]-FDG-avid lesions by performing the TOST equivalence test [20]CC BY · PubMed Central
Fig. 5 Bland–Altman plot showing SUVmax measurement differences of 214 lesions between the 75 s and 57 s PET/CT datasets plotted against the mean SUVmax. In order to interpret these powerful Bland–Altman plots properly, it is essential to know that the differences between the quantified SUVs are plotted on the y-axis and the average of the SUVs is visualized on the x-axis
Fig. 5 Bland–Altman plot showing SUVmax measurement differences of 214 lesions between the 75 s and 57 s PET/CT datasets plotted against the mean SUVmax. In order to interpret these powerful Bland–Altman plots properly, it is essential to know that the differences between the quantified SUVs are plotted on the y-axis and the average of the SUVs is visualized on the x-axisCC BY · PubMed Central
Fig. 6 Bland–Altman plot showing SUVmean measurement differences of 214 lesions between 75 s and 57 s PET/CT datasets plotted against the mean SUVmean. In order to interpret these powerful Bland–Altman plots properly, it is essential to know that the differences between the quantified SUVs are plotted on the y-axis, and the average of the SUVs is visualized on the x-axis
Fig. 6 Bland–Altman plot showing SUVmean measurement differences of 214 lesions between 75 s and 57 s PET/CT datasets plotted against the mean SUVmean. In order to interpret these powerful Bland–Altman plots properly, it is essential to know that the differences between the quantified SUVs are plotted on the y-axis, and the average of the SUVs is visualized on the x-axisCC BY · PubMed Central
Fig. 7 Boxplots representing COVliver and COVmediastinum for different bw classes - 75 s and 57 s PET/CT acquisition time
Fig. 7 Boxplots representing COVliver and COVmediastinum for different bw classes - 75 s and 57 s PET/CT acquisition timeCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 6

Metadata

Authors
Pilz, J., Hehenwarter, L., Zimmermann, G., Rendl, G., Schweighofer-Zwink, G., Beheshti, M., & Pirich, C.
Affiliations
Paracelsus Medical University (AT)
Corresponding author
Pirich, Christian
Venue
EJNMMI Research
Published
2021-05-01
Volume
11
Issue
1
Pages
44-44
ISSN
2191-219X (ISSN-L)
OpenAlex
W3159563079
Cited by
6
References
31
Citations by year
2025: 2 · 2022: 3 · 2021: 1
FWCI
0.53
Type
journal article
Language
en
Open access
Licence
Locations
  • EJNMMI Research (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Paracelsus Medizinische Privatuniversität (D-17/02/007-PIL)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
Keywords
18F-FDG PET, acquisition time reduction, diagnostic equivalence, standardized uptake value, lesion detection rate, image quality, melanoma, lung cancer, head and neck cancer, list-mode data, semi-quantitative analysis, whole-body PET/CT

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Feasibility of equivalent performance of 3D TOF [18F]-FDG PET/CT with reduced acquisition time using clinical and semiquantitative parameters. https://app.cochat.ai/papers/10.1186/s13550-021-00784-9
The paper
Pilz, J., Hehenwarter, L., Zimmermann, G., Rendl, G., Schweighofer-Zwink, G., Beheshti, M., & Pirich, C. (2021). Feasibility of equivalent performance of 3D TOF [18F]-FDG PET/CT with reduced acquisition time using clinical and semiquantitative parameters. EJNMMI Research. https://doi.org/10.1186/s13550-021-00784-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.