Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Proprioceptive precision is impaired in Ehlers-Danlos syndrome

Open access

Abstract

It has been suggested that people with Ehlers-Danlos syndrome (EDS), or other similar connective tissue disorders, may have proprioceptive impairments, the reason for which is still unknown. We recently found that EDS patients were less precise than healthy controls when estimating their felt hand's position relative to visible peripheral reference locations, and that this deficit was positively correlated with the severity of joint hypermobility. We further explore proprioceptive abilities in EDS by having patients localize their non-dominant left hand at a greater number of workspace locations than in our previous study. Additionally, we explore the relationship between chronic pain and proprioceptive sensitivity. We found that, although patients were just as accurate as controls, they were not as precise. Patients showed twice as much scatter than controls at all locations, but the degree of scatter did not positively correlate with chronic pain scores. This further supports the idea that a proprioceptive impairment pertaining to precision is present in EDS, but may not relate to the magnitude of chronic pain.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s40064-015-1089-1

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 a Average horizontal and sagittal reach endpoint errors. Error bars reflect standard error of the mean. b Average two-dimensional errors (centre of ellipses, represented by circles) and precision of reach endpoints (95% error ellipses) at each target-hand position (X’s), for EDS patients (dashed) and healthy controls (solid). c Mean elliptical areas (cm2) collapsed across all hand-target locations. Error bars reflect standard error of the mean. d Mean axis length (cm) for the major, minor and summed axes. Error bars reflect standard error of the mean.
Figure 1 a Average horizontal and sagittal reach endpoint errors. Error bars reflect standard error of the mean. b Average two-dimensional errors (centre of ellipses, represented by circles) and precision of reach endpoints (95% error ellipses) at each target-hand position (X’s), for EDS patients (dashed) and healthy controls (solid). c Mean elliptical areas (cm2) collapsed across all hand-target locations. Error bars reflect standard error of the mean. d Mean axis length (cm) for the major, minor and summed axes. Error bars reflect standard error of the mean.CC BY · PubMed Central
Figure 2 a Side view of the general experimental set-up. b Six locations served as start and final target sites for the non-dominant left hand. c The robotic manipulandum restricted active movement of the left target-hand along a straight path from one target site (start) to another target site (target position). Participants reached with their seen right hand to the felt location of the unseen left target-hand.
Figure 2 a Side view of the general experimental set-up. b Six locations served as start and final target sites for the non-dominant left hand. c The robotic manipulandum restricted active movement of the left target-hand along a straight path from one target site (start) to another target site (target position). Participants reached with their seen right hand to the felt location of the unseen left target-hand.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Cited by

See all 56

Metadata

Authors
Clayton, H. A., Jones, S. A. H., & Henriques, D. Y. P.
Affiliations
  • York University (CA)
  • Dalhousie University (CA)
Corresponding author
Henriques, Denise Y P
Venue
SpringerPlus
Published
2015-07-07
Volume
4
Issue
1
Pages
323-323
ISSN
2193-1801 (ISSN-L)
OpenAlex
W1641937948
Cited by
50
References
37
Citations by year
2026: 9 · 2025: 6 · 2024: 5 · 2023: 7 · 2022: 3 · 2021: 5 · 2020: 4 · 2019: 5 · 2018: 1 · 2017: 2 · 2016: 2 · 2015: 1
FWCI
1.37
Type
journal article
Language
en
Open access
Locations
  • SpringerPlus (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Connective tissue disorders research
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
Keywords
Ehlers-Danlos syndrome, proprioception, joint hypermobility, chronic pain, connective tissue diseases

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Proprioceptive precision is impaired in Ehlers-Danlos syndrome. https://app.cochat.ai/papers/10.1186/s40064-015-1089-1
The paper
Clayton, H. A., Jones, S. A. H., & Henriques, D. Y. P. (2015). Proprioceptive precision is impaired in Ehlers-Danlos syndrome. SpringerPlus. https://doi.org/10.1186/s40064-015-1089-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.