The 678 Hz acoustic immittance probe tone: A more definitive indicator of PET than the traditional 226 Hz method
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: The accurate diagnosis of Eustachian tube (ET) dysfunction can be very difficult. Our aim is to determine whether a 678 Hz probe tone is a more accurate indicator of Patulous ET (PET) than the 226 Hz probe tone when used in compliance over time (COT) testing. Methods: Twenty subjects (11 normal ET ears and 7 PET ears) were individually seated in an examination room and connected to a GSI TympStar Middle Ear Analyzer. The order of probe tone frequency (678 or 226 Hz) was randomized. Baseline “testing” COT recordings for each ear undergoing testing were completed. Subjects were instructed to occlude their contralateral nostril and to breathe forcefully in and out through their ipsilateral nostril until the test had run to completion. This process was repeated with the probe tone that had not been previously run. For the control group, each subject had one random ear tested. For the experimental group, only the affected ear(s) was tested. Wilcoxon rank rum tests were performed to determine statistical significance. Results: The baseline COT measurements for the control group and PET group were similar, 0.86 mL (SD = 0.34) and 0.74 (SD = 0.33) respectively. Comparing the 226 Hz tone between groups revealed that PET patients had a median COT difference 0.19 mL higher than healthy ET patients, and for the 678 Hz tone, PET patients had a median COT difference of 0.57 mL higher than healthy ET patients. Both were deemed to be statistically significant ( p = 0.002, p = 0.004 respectively). The was a statistically significant median COT difference between the 678 Hz and 226 Hz of 0.61 mL ( p = 0.034) for the PET group, while the same comparison for the control group of 0.05 mL was not significant ( p = 0.262), suggesting that the 678 Hz tone yields a larger response for PET than the 226 Hz tone, and no difference for the control group, thus making it less prone to artifact noise interference. Conclusion: The 678 Hz probe tone is a more reliable indicator of ET patency, and should be preferably used over the 226 Hz tone for future COT testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the false-positive rate was too high, and the signals were too tiny to properly interpret with the 226 Hz tone when COT testing was conducted in the eustachian tube clinic [7]”
From Assessment of sensitivity of acoustic reflex decay test in diagnosis of patulous eustachian tube (2024) · cites this paper as [7]
In the citing paper
“It is crucial that the patient not breathe too loudly throughout the test because the microphone in the ear canal will detect this as a signal and produce noise artefact [7]”
From Assessment of sensitivity of acoustic reflex decay test in diagnosis of patulous eustachian tube (2024) · cites this paper as [7]
In the citing paper
“utilizing a 678 Hz pure tone is more effective at predicting PET than any other tone that has been utilized previously”
From Assessment of sensitivity of acoustic reflex decay test in diagnosis of patulous eustachian tube (2024) · cites this paper as [7]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schilder, A. G. M., Bhutta, M. F., Butler, C. C., Holy, C., Levine, L. H., Kvaerner, K. J., Norman, G., Pennings, R. J., Poe, D., Silvola, J. T., et al. (2015) · Clinical Otolaryngology · doi:10.1111/coa.12475 · Cited by 407
McCoul, E. D., Anand, V. K., & Christos, P. J. (2012) · The Laryngoscope · doi:10.1002/lary.23223 · Cited by 331
Research works printed but not linked: 20
- Bartlett C, 2010, J Otolaryngol Head Neck Surg, 39, 259
- 10.1001/archoto.2012.1293 · DOI
- 10.1007/s00234-016-1663-4 · DOI · Paper page
- Poe DS, 2008, Ballenger's Textbook of Otolaryngology
- 10.1016/S0194-5998(97)70302-4 · DOI · Paper page
- Bluestone CD, Klein JO. Otitis media and Eustachian tube dysfunction. In: Bluestone CD, Sylven SE, Alper CM, et al, editors. Pediatric Otolaryngology, 4. Philadelphia: W.B. Saunders; 2003. p. 474.
- 10.3766/jaaa.22.4.2 · DOI · Paper page
- 10.1016/j.otohns.2010.07.004 · DOI
- 10.1056/NEJMicm1403262 · doi:10.1056/nejmicm1403262
- 10.1097/mao.0b013e31804d4998 · DOI · Paper page
- 10.1002/(SICI)1098-108X(199904)25:3<353::AID-EAT16>3.0.CO;2-M · DOI
- 10.1067/mhn.2003.34 · DOI
- 10.1288/00005537-198109000-00003 · DOI · Paper page
- 10.1017/S0022215100109946 · doi:10.1017/s0022215100109946
- Spear SA, 2013, Recent advances in otolaryngology head and neck surgery, Vol. 2
- 10.1016/j.amjoto.2006.06.019 · DOI
- Northern JL, 1975, Handbook of Clinical Impedance Audiometry, 21
- Henry DF, 1993, J Am Acad Audiol, 4, 53
- 10.1016/j.anl.2016.03.008 · DOI
- 10.1097/MAO.0000000000001130 · DOI · Paper page
Cited by
Assessment of sensitivity of acoustic reflex decay test in diagnosis of patulous eustachian tube
Attia, A. A. A., Abou-Setta, A. E. A., & Ashary, Y. M. (2024) · The Egyptian Journal of Otolaryngology · doi:10.1186/s43163-024-00579-4
Metadata
- Authors
- Pyne, J. M., Lawen, T. I., Floyd, D. D., & Bance, M.
- Venue
- Journal of Otolaryngology - Head & Neck Surgery
- Publisher
- SAGE Publications
- Published
- 2018-01
- Volume
- 47
- Issue
- 1
- ISSN
- 1916-0216
- Cited by
- 5
- References
- 2
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The 678 Hz acoustic immittance probe tone: A more definitive indicator of PET than the traditional 226 Hz method. https://app.cochat.ai/papers/10.1186/s40463-018-0290-y
- The paper
- Pyne, J. M., Lawen, T. I., Floyd, D. D., & Bance, M. (2018). The 678 Hz acoustic immittance probe tone: A more definitive indicator of PET than the traditional 226 Hz method. Journal of Otolaryngology - Head & Neck Surgery. https://doi.org/10.1186/s40463-018-0290-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.