Recent updates for biomaterials used in total hip arthroplasty
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Background: Total hip arthroplasty (THA) is probably one of the most successful surgical interventions performed in medicine. Through the revolution of hip arthroplasty by principles of low friction arthroplasty was introduced by Sir John Charnley in 1960s. Thereafter, new bearing materials, fixation methods, and new designs has been improved. The main concern regarding failure of THA has been the biological response to particulate polyethylene debris generated by conventional metal on polyethylene bearing surfaces leading to osteolysis and aseptic loosening of the prosthesis. To resolve these problems, the materials of the modern THA were developed since then. Methods: A literature search strategy was conducted using various search terms in PUBMED. The highest quality articles that met the inclusion criteria and best answered the topics of focus of this review were selected. Key search terms included ‘total hip arthroplasty’, ‘biomaterials’, ‘stainless steel’, ‘cobalt-chromium’, ‘titanium’, ‘polyethylene’, and ‘ceramic’. Results: The initial search retrieved 6921 articles. Thirty-two articles were selected and used in the review. Conclusion: This article introduces biomaterials used in THA and discusses various bearing materials in currentclinical use in THA as well as the newer biomaterials which may even further decrease wear and improve THA survivorship.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030
Kurtz, S., Ong, K., Lau, E., Mowat, F., & Halpern, M. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200704000-00012 · Cited by 8,698
The operation of the century: total hip replacement
Learmonth, I. D., Young, C., & Rorabeck, C. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60457-7 · Cited by 2,848 · cited 2×
“With the increasing use of THA in younger and more active patients, the revision rate becomes higher [32], and there has been concerns about the role of PE wear particles in osteolysis and loosening [31].”
BackgroundPrevalence of Total Hip and Knee Replacement in the United States
Maradit Kremers, H., Larson, D. R., Crowson, C. S., Kremers, W. K., Washington, R. E., Steiner, C. A., Jiranek, W. A., & Berry, D. J. (2015) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.n.01141 · Cited by 1,723
The Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,599 · cited 1×
“However, since some corrosion was inevitable, it has been recommended that stainless steel only be used for short duration purposes [35].”
BackgroundTissue-Integrated Prostheses. Osseointegration in Clinical Dentistry
Brånemark, P., Zarb, G. A., Albrektsson, T. O., & Rosen, H. M. (1986) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198603000-00037 · Cited by 1,556 · cited 1×
“implant contact and reduce risk of loosening, the use of porous metals andcoatingswere developed [37].”
BackgroundWhat future for zirconia as a biomaterial?
Chevalier, J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.034 · Cited by 1,228
WILLERT, H.-G., BUCHHORN, G. H., FAYYAZI, A., FLURY, R., WINDLER, M., KÖSTER, G., & LOHMANN, C. H. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200501000-00006 · Cited by 1,192
Preparation of bioactive Ti and its alloys via simple chemical surface treatment
Kim, H.-M., Miyaji, F., Kokubo, T., & Nakamura, T. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199611)32:3<409::aid-jbm14>3.0.co;2-b · Cited by 1,005
ARTHROPLASTY OF THE HIP A New Operation
CHARNLEY, J. (1961) · The Lancet · doi:10.1016/s0140-6736(61)92063-3 · Cited by 843
URBAN, R. M., JACOBS, J. J., TOMLINSON, M. J., GAVRILOVIC, J., BLACK, J., & PEOC'H, M. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200004000-00002 · Cited by 787
Harris, W. H. (1995) · PubMed · Cited by 732
A literature review of the association between wear rate and osteolysis in total hip arthroplasty
Dumbleton, J. H., Manley, M. T., & Edidin, A. A. (2002) · The Journal of Arthroplasty · doi:10.1054/arth.2002.33664 · Cited by 710
Berry, D. J., Harmsen, W. S., Cabanela, M. E., & Morrey, B. F. (2002) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200202000-00002 · Cited by 679
Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis
Daniel, J., Pynsent, P. B., & McMinn, D. J. W. (2004) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.86b2.14600 · Cited by 672
Yang, Y., Kim, K.-H., & Ong, J. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.029 · Cited by 667
YERSINIA ENTEROCOLITICA INFECTIONS AND PORK: THE MISSING LINK
Tauxe, R. V., Wauters, G., Goossens, V., Noyen, R. V., Vandepitte, J., Martin, S. M., Mol, P. D., & Thiers, G. (1987) · The Lancet · doi:10.1016/s0140-6736(87)91683-7 · Cited by 651
De Aza, A. H., Chevalier, J., Fantozzi, G., Schehl, M., & Torrecillas, R. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00206-x · Cited by 625
Chen, W., Liu, Y., Courtney, H. S., Bettenga, M., Agrawal, C. M., Bumgardner, J. D., & Ong, J. L. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.07.003 · Cited by 594
Green, T. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00140-9 · Cited by 569
Abu-Amer, Y., Darwech, I., & Clohisy, J. C. (2007) · Arthritis Research & Therapy · doi:10.1186/ar2170 · Cited by 534
Balla, V. K., Bodhak, S., Bose, S., & Bandyopadhyay, A. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.01.046 · Cited by 504
Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE)
Muratoglu, O. K., Bragdon, C. R., O’Connor, D., Jasty, M., Harris, W. H., Gul, R. M., & Garry, F. J. M. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00039-3 · Cited by 455
METALLOSIS AFTER CONTEMPORARY METAL-ON-METAL TOTAL HIP ARTHROPLASTY: FIVE TO NINE-YEAR FOLLOW-UP
KOROVESSIS, P. G., Petsinis, G., Repanti, M., & Repantis, T. (2006) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200606000-00003 · Cited by 398
Graded surface structure of bioactive titanium prepared by chemical treatment
Kim, H.-M., Miyaji, F., Kokubo, T., Nishiguchi, S., & Nakamura, T. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199905)45:2<100::aid-jbm4>3.0.co;2-0 · Cited by 328
EARLY OSTEOLYSIS FOLLOWING SECOND-GENERATION METAL-ON-METAL HIP REPLACEMENT
PARK, Y.-S., MOON, Y.-W., LIM, S.-J., YANG, J.-M., AHN, G., & CHOI, Y.-L. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200507000-00014 · Cited by 322
Orthopedic applications of silicon nitride ceramics
Bal, B. S., & Rahaman, M. N. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.04.031 · Cited by 314
McKELLOP, H., SHEN, F.-W., LU, B., CAMPBELL, P., & SALOVEY, R. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200012000-00004 · Cited by 264
Vitamin E diffused, highly crosslinked UHMWPE: a review
Oral, E., & Muratoglu, O. K. (2010) · International Orthopaedics · doi:10.1007/s00264-010-1161-y · Cited by 247
Ceramics and ceramic coatings in orthopaedics
McEntire, B. J., Bal, B. S., Rahaman, M. N., Chevalier, J., & Pezzotti, G. (2015) · Journal of the European Ceramic Society · doi:10.1016/j.jeurceramsoc.2015.07.034 · Cited by 221
Ong, J. L., Lucas, L. C., Lacefield, W. R., & Rigney, E. D. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90192-q · Cited by 211
Titanium as the material of choice for cementless femoral components in total hip arthroplasty.
Head, W. C., Dj, B., & Emerson, R. H. (1995) · PubMed · Cited by 203
MILOŠEV, I., TREBŠE, R., KOVAČ, S., CÖR, A., & PIŠOT, V. (2006) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200606000-00002 · Cited by 197
UHMWPE for arthroplasty: past or future?
Brach del Prever, E. M., Bistolfi, A., Bracco, P., & Costa, L. (2009) · Journal of Orthopaedics and Traumatology · doi:10.1007/s10195-008-0038-y · Cited by 188
BEARING SURFACE OPTIONS FOR TOTAL HIP REPLACEMENT IN YOUNG PATIENTS
Heisel, C., Silva, M., & Schmalzried, T. P. (2003) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200307000-00026 · Cited by 137
Highly lubricated polymer interfaces for advanced artificial hip joints through biomimetic design
Ishihara, K. (2015) · Polymer Journal · doi:10.1038/pj.2015.45 · Cited by 133
Ceramic-on-ceramic bearings in hip arthroplasty: State of the art and the future
Jeffers, J. R. T., & Walter, W. L. (2012) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.94b6.28801 · Cited by 133
Berger, R. A., Jacobs, J. J., QUIGLEY, L. R., Rosenberg, A. G., & Galante, J. O. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199711000-00022 · Cited by 126
Fracture of the femoral head after ceramic-on-polyethylene total hip arthroplasty
CALLAWAY, G. H., Flynn, W. F., Ranawat, C. S., & Sculco, T. P. (1995) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(05)80087-7 · Cited by 116
Berger, R. A., Jacobs, J. J., QUIGLEY, L. R., et al. (1997) · PubMed · Cited by 106
Kim, H.-M., Takadama, H., Miyaji, F., Kokubo, T., Nishiguchi, S., & Nakamura, T. (2000) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008924102096 · Cited by 90
Kyomoto, M., Moro, T., Konno, T., Takadama, H., Yamawaki, N., Kawaguchi, H., Takatori, Y., Nakamura, K., & Ishihara, K. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31134 · Cited by 78
Retrospective lifetime estimation of failed and explanted diamond-like carbon coated hip joint balls
Hauert, R., Falub, C. V., Thorwarth, G., Thorwarth, K., Affolter, C., Stiefel, M., Podleska, L. E., & Taeger, G. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.04.016 · Cited by 73
Nanostructured diamondlike carbon thin films for medical applications
Narayan, R. J. (2005) · Materials Science and Engineering C · doi:10.1016/j.msec.2005.01.026 · Cited by 70
Antibacterial effect and cytotoxicity of Ag‐doped functionally graded hydroxyapatite coatings
Bai, X., Sandukas, S., Appleford, M. R., Ong, J. L., & Rabiei, A. (2011) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31985 · Cited by 69
Boutin, P. (2014) · Orthopaedics & Traumatology Surgery & Research · doi:10.1016/j.otsr.2013.12.004 · Cited by 55
Kyomoto, M., Moro, T., Iwasaki, Y., Miyaji, F., Kawaguchi, H., Takatori, Y., Nakamura, K., & Ishihara, K. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32280 · Cited by 52
Si, H., Zeng, Y., Cao, F., Pei, F., & Shen, B. (2015) · Hip International · doi:10.5301/hipint.5000223 · Cited by 25
Cited by
Lee, S. H., Jeon, S., Qu, X., Kang, M. S., Lee, J. H., Han, D.-W., & Hong, S. W. (2022) · Nano Convergence · doi:10.1186/s40580-022-00329-3 · Cited by 39
Metadata
- Authors
- Hu, C. Y., & Yoon, T.-R.
- Venue
- Biomaterials Research
- Published
- 2018-12-05
- Volume
- 22
- Issue
- 1
- Pages
- 33-33
- ISSN
- 1226-4601 (ISSN-L)
- 2055-7124
- OpenAlex
- W2899730390
- Cited by
- 186
- References
- 47
- FWCI
- 15.08
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.