A critical survey of technologies of large offshore wind farm integration: summary, advances, and perspectives
Open accessThe DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Abstract
Offshore wind farms (OWFs) have received widespread attention for their abundant unexploited wind energy potential and convenient locations conditions. They are rapidly developing towards having large capacity and being located further away from shore. It is thus necessary to explore effective power transmission technologies to connect large OWFs to onshore grids. At present, three types of power transmission technologies have been proposed for large OWF integration. They are: high voltage alternating current (HVAC) transmission, high voltage direct current (HVDC) transmission, and low-frequency alternating current (LFAC) or fractional frequency alternating current transmission. This work undertakes a comprehensive review of grid connection technologies for large OWF integration. Compared with previous reviews, a more exhaustive summary is provided to elaborate HVAC, LFAC, and five HVDC topologies, consisting of line-commutated converter HVDC, voltage source converter HVDC, hybrid-HVDC, diode rectifier-based HVDC, and all DC transmission systems. The fault ride-through technologies of the grid connection schemes are also presented in detail to provide research references and guidelines for researchers. In addition, a comprehensive evaluation of the seven grid connection technologies for large OWFs is proposed based on eight specific indicators. Finally, eight conclusions and six perspectives are outlined for future research in integrating large OWFs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Murty, V. V. S. N., & Kumar, A. (2020) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-019-0147-z · Cited by 268
RetractedVSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216
IEEE Transactions on Power Systems
(2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.59 · Cited by 666
Fernández‐Guillamón, A., Gómez‐Lázaro, E., Muljadi, E., & Molina‐García, Á. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109369 · Cited by 641
HVDC Transmission: Technology Review, Market Trends and Future Outlook
Alassi, A., Bañales, S., Ellabban, O., Adam, G., & MacIver, C. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.04.062 · Cited by 476
Comprehensive overview of meta-heuristic algorithm applications on PV cell parameter identification
Yang, B., Wang, J., Zhang, X., Yu, T., Yao, W., Shu, H., Zeng, F., & Sun, L. (2020) · Energy Conversion and Management · doi:10.1016/j.enconman.2020.112595 · Cited by 382
Self-citationYang, B., Yu, T., Shu, H., Dong, J., & Jiang, L. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.08.027 · Cited by 381
Self-citationYang, B., Zhong, L., Zhang, X., Shu, H., Yu, T., Li, H., Jiang, L., & Sun, L. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.01.150 · Cited by 377
Self-citationYang, B., Zhang, X., Yu, T., Shu, H., & Fang, Z. (2017) · Energy Conversion and Management · doi:10.1016/j.enconman.2016.10.062 · Cited by 370
Self-citationLow-Voltage Ride-Through of Single-Phase Transformerless Photovoltaic Inverters
Yang, Y., Blaabjerg, F., & Wang, H. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2282966 · Cited by 358
Topologies of multiterminal HVDC-VSC transmission for large offshore wind farms
Gomis‐Bellmunt, O., Liang, J., Ekanayake, J. B., King, R. L., & Jenkins, N. (2010) · Electric Power Systems Research · doi:10.1016/j.epsr.2010.09.006 · Cited by 296
Yang, B. F., Yu, T., Shu, H., Zhang, Y., Chen, J., Sang, Y., & Jiang, L. (2017) · Renewable Energy · doi:10.1016/j.renene.2017.12.047 · Cited by 289
Self-citationYang, B. F., Yu, T., Zhang, X., Li, H., Shu, H., Sang, Y., & Jiang, L. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.10.074 · Cited by 279
Self-citationNonlinear maximum power point tracking control and modal analysis of DFIG based wind turbine
Yang, B. F., Jiang, L., Wang, L., Yao, W., & Wu, Q. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.07.036 · Cited by 277
Self-citationImpedance Modeling and Stability Analysis of Grid-Connected DFIG-Based Wind Farm With a VSC-HVDC
Sun, K., Yao, W., Fang, J., Ai, X., Wen, J., & Cheng, S. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2901747 · Cited by 213
Self-citationNasiri, M., Milimonfared, J., & Fathi, S. H. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.03.079 · Cited by 213
Chen, J., Yao, W., Zhang, C., Ren, Y., & Jiang, L. (2018) · Renewable Energy · doi:10.1016/j.renene.2018.11.048 · Cited by 188
Self-citationReview of VSC HVDC connection for offshore wind power integration
Korompili, A., Wu, Q., & Zhao, H. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.064 · Cited by 172
Impedance Modeling and Analysis of MMC-HVDC for Offshore Wind Farm Integration
Ji, K., Tang, G., Pang, H., & Yang, J. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2946450 · Cited by 145
Xiong, Y., Yao, W., Wen, J., Lin, S., Ai, X., Fang, J., Wen, J., & Cheng, S. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.2998579 · Cited by 136
Self-citationHybrid HVDC for Integrating Wind Farms With Special Consideration on Commutation Failure
Zeng, R., Xu, L., Yao, L., Finney, S. J., & Wang, Y. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2440354 · Cited by 123
Coordinated Control of Parallel DR-HVDC and MMC-HVDC Systems for Offshore Wind Energy Transmission
Li, R., Yu, L., Xu, L., & Adam, G. P. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931197 · Cited by 112
Resilient Wide-Area Damping Control Using GrHDP to Tolerate Communication Failures
Shen, Y., Yao, W., Wen, J., He, H., & Jiang, L. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2803822 · Cited by 110
Self-citationReview of protection and fault handling for a flexible DC grid
He, J., Chen, K., Li, M., Luo, Y., Liang, C., & Xu, Y. (2020) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-020-00157-9 · Cited by 110
Cost Analysis and Comparison of HVAC, LFAC and HVDC for Offshore Wind Power Connection
Xiang, X. J., Merlin, M., & Green, T. C. (2016) · IET International Conference on AC and DC Power Transmission (ACDC) · doi:10.1049/cp.2016.0386 · Cited by 110
Operation and Control of a DC-Grid Offshore Wind Farm Under DC Transmission System Faults
Deng, F., & Chen, Z. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2261561 · Cited by 108
Hybrid Topology of a Diode-Rectifier-Based HVDC System for Offshore Wind Farms
Chang, Y., & Cai, X. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2881768 · Cited by 104
Wang, Q., Yao, W., Fang, J., Ai, X., Wen, J., Yang, X., Xie, H., & Huang, X. (2020) · Applied Energy · doi:10.1016/j.apenergy.2019.114132 · Cited by 101
Self-citationZhang, Y., Ravishankar, J., Fletcher, J., Li, R., & Han, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.108 · Cited by 90
Comprehensive review of commutation failure in HVDC transmission systems
Zhou, H., Yao, W., Ai, X., Li, D., Wen, J., & Li, C. (2022) · Electric Power Systems Research · doi:10.1016/j.epsr.2021.107768 · Cited by 87
Self-citationDong, H., Xu, Z. G., Song, P., Tang, G., Xu, Q., & Sun, L. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2631136 · Cited by 78
Meng, Y., Yan, S., Wu, K., Ning, L., Li, X., Wang, X., & Wang, X. (2021) · Renewable Energy · doi:10.1016/j.renene.2021.07.137 · Cited by 76
ALL-DC Offshore Wind Farm With Series-Connected Wind Turbines to Overcome Unequal Wind Speeds
Rong, F., Wu, G., Li, X., Huang, S., & Zhou, B. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2834965 · Cited by 73
Modeling and Control of Multi-Terminal VSC HVDC Systems
Beerten, J., & Belmans, R. J. M. (2012) · Energy Procedia · doi:10.1016/j.egypro.2012.06.093 · Cited by 71
Overvoltage Limitation Method of an Offshore Wind Farm With DC Series-Parallel Collection Grid
Zhang, H., Gruson, F., R., D. M. F., & Saudemont, C. (2018) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2018.2829929 · Cited by 68
Modelling of MMC-HVDC Systems – An Overview
Beddard, A., & Barnes, M. (2015) · Energy Procedia · doi:10.1016/j.egypro.2015.11.423 · Cited by 68
Beza, M., & Bongiorno, M. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.04.004 · Cited by 56
Simulation of Startup Sequence of an Offshore Wind Farm With MMC-HVDC Grid Connection
Cai, L., Karaagac, U., & Mahseredjian, J. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2517184 · Cited by 52
A non-unit boundary protection of DC line for MMC-MTDC grids
Zhang, S., Zou, G., Wang, C., Li, J., & Xu, B. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.105538 · Cited by 51
Key technologies of VSC-HVDC and its application on offshore wind farm in China
Wu, J., Wang, Z., Xu, L., & Wang, G. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.04.061 · Cited by 44
Coordinated Control for an Offshore Wind Power Plant to Provide Fault Ride Through Capability
Aragüés‐Peñalba, M., Gomis‐Bellmunt, O., & Martins, M. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2344172 · Cited by 41
Ndreko, M., Popov, M., & van der Meijden, M. A. M. M. (2016) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2016.08.009 · Cited by 41
Khan, A., Seyedmahmoudian, M., Raza, A., & Stojcevski, A. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111106 · Cited by 39
Novel Submodule Topology With Large Current Operation and DC-Fault Blocking Capability for MMC-HVDC
Meng, Y., Zou, Y., Wang, H., Kong, Y., Du, Z., & Wang, X. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3011228 · Cited by 38
Control of the Parallel Operation of DR-HVDC and VSC-HVDC for Offshore Wind Power Transmission
Nami, A., Rodríguez-Amenedo, J. L., Arnaltes, S., Alvarez, M. A. C., & Alves, R. (2021) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2021.3095529 · Cited by 34
AC fault ride through control strategy on inverter side of hybrid HVDC transmission systems
Zhou, Z., Chen, Z., Wang, X., Dingxiang, D., Yang, G., Wang, Y., & Hao, L. (2019) · Journal of Modern Power Systems and Clean Energy · doi:10.1007/s40565-019-0546-1 · Cited by 32
Assessment of a non linear current control technique applied to MMC-HVDC during grid disturbances
Ramírez, D., Martinez‐Rodrigo, F., de Pablo, S., & Herrero, L. C. (2016) · Renewable Energy · doi:10.1016/j.renene.2016.09.050 · Cited by 29
A Coordinated Frequency Regulation Strategy for VSC-HVDC Integrated Offshore Wind Farms
Ye, Y., Lu, Z., Xie, L., & Qiao, Y. (2018) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2018.8586620 · Cited by 23
Control strategies of a dc based offshore wind farm with series connected collection grid
Zhang, H., R., D. M. F., Saudemont, C., & Gruson, F. (2016) · IEEE International Energy Conference (ENERGYCON) · doi:10.1109/energycon.2016.7514062 · Cited by 15
Sasongko, F., Hagiwara, M., & Akagi, H. (2013) · IEEE International Future Energy Electronics Conference (IFEEC) · doi:10.1109/ifeec.2013.6687555 · Cited by 15
Zhu, J., Booth, C. D., Adam, G. P., et al. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2015.02.015 · Cited by 14
Impact of controller parameters on stability of MMC-based HVDC systems for offshore wind farms
Lyu, J., & Cai, X. (2015) · Renewable Power Generation Conference (RPG) · doi:10.1049/cp.2015.0441 · Cited by 14
Zhang, J., Li, K., Liu, W., Sun, K., Liu, Z., & Wang, Z.-D. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.107010 · Cited by 11
Hu, C., Tong, Y., Jing, J., & Zhao, C. (2020) · Energy Reports · doi:10.1016/j.egyr.2020.11.088 · Cited by 10
Control of HVDC systems based on diode rectifier for offshore wind farm applications
Flåten, I., Bergna‐Diaz, G., Sánchez, S., & Tedeschi, E. (2017) · Energy Procedia · doi:10.1016/j.egypro.2017.10.365 · Cited by 8
Tian, X., Li, Y., Guo, M., Ye, R., Huang, R., & Zhang, M. (2018) · International Conference on Power System Technology (POWERCON) · doi:10.1109/powercon.2018.8602131 · Cited by 6
Cui, S., Hu, J., & Doncker, R. W. D. (2019) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2019.8807512 · Cited by 2
Cited by
Critical summary and perspectives on state-of-health of lithium-ion battery
Yang, B., Qian, Y., Li, Q., Chen, Q., Wu, J., Luo, E., Xie, R., Zheng, R., Yan, Y., Su, S., et al. (2024) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2023.114077 · Cited by 202
Self-citationKumar, D., Nasimov, R., Singh, A., Jha, A., Jha, A., & Rizwan, M. (2025) · Applied Computational Intelligence and Soft Computing · doi:10.1155/acis/5516151 · Cited by 8
“Energy storage systems [8] can be utilized with renewable energy sources [9] for better management of the supply of renewable energy and power generation.”
Metadata
- Authors
- Yang, B., Liu, B., Zhou, H., Wang, J., Yao, W., Wu, S., Shu, H., & Ren, Y.
- Venue
- Protection and Control of Modern Power Systems
- Published
- 2022-05-02
- Volume
- 7
- Issue
- 1
- ISSN
- 2367-0983 (ISSN-L)
- 2367-2617
- OpenAlex
- W4225263261
- Cited by
- 197
- References
- 57
- FWCI
- 11.51
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.