The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Particle Radiation Therapy Using Proton and Heavier Ion Beams
Abstract
Particle beams like protons and heavier ions offer improved dose distributions compared with photon (also called x-ray) beams and thus enable dose escalation within the tumor while sparing normal tissues. Although protons have a biologic effectiveness comparable to photons, ions, because they are heavier than protons, provide a higher biologic effectiveness. Recent technologic developments in the fields of accelerator engineering, treatment planning, beam delivery, and tumor visualization have stimulated the process of transferring particle radiation therapy (RT) from physics laboratories to the clinic. This review describes the physical, biologic, and technologic aspects of particle beam therapy. Clinical trials investigating proton and carbon ion RT will be summarized and discussed in the context of their relevance to recent concepts of treatment with RT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiological Use of Fast Protons
Wilson, R. R. (1946) · Radiology · doi:10.1148/47.5.487 · Cited by 1,403
Zietman, A. L., DeSilvio, M. L., Slater, J. D., Rossi, C. J., Miller, D. W., Adams, J. A., & Shipley, W. U. (2005) · JAMA · doi:10.1001/jama.294.10.1233 · Cited by 1,224
Intensity-modulated radiation therapy, protons, and the risk of second cancers
Hall, E. J. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.01.027 · Cited by 1,110
Zelefsky, M. J., Fuks, Z., Hunt, M., Yamada, Y., Marion, C., Ling, C. C., Amols, H., Venkatraman, E. S., & Leibel, S. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02857-2 · Cited by 775
Magnetic scanning system for heavy ion therapy
Haberer, T., Becher, W., Schardt, D., & Kraft, G. (1993) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(93)91335-k · Cited by 730
Physical aspects of a real-time tumor-tracking system for gated radiotherapy
Shirato, H., Shimizu, S., Kunieda, T., Kitamura, K., van Herk, M., Kagei, K., Nishioka, T., Hashimoto, S., Fujita, K., Aoyama, H., et al. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00748-3 · Cited by 662
Proton radiation therapy for chordomas and chondrosarcomas of the skull base
Hug, E. B., Loredo, L. N., Slater, J. D., Devries, A., Grove, R. I., Schaefer, R. A., Rosenberg, A. E., & Slater, J. M. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.91.3.0432 · Cited by 510
Respiratory gated irradiation system for heavy-ion radiotherapy
Minohara, S., Kanai, T., Endo, M., Noda, K., & Kanazawa, M. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00524-1 · Cited by 457
Miralbell, R., Lomax, A., Cella, L., & Schneider, U. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02982-6 · Cited by 408
Shipley, W. U., Verhey, L. J., Munzenrider, J. E., Suit, H. D., Urie, M. M., McManus, P. L., Young, R. H., Shipley, J. W., Zietman, A. L., Biggs, P. J., et al. (1995) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(95)00063-5 · Cited by 407
Cited by
Cancer and Radiation Therapy: Current Advances and Future Directions
Baskar, R., Lee, K. A., Yeo, R., & Yeoh, K.-W. (2012) · International Journal of Medical Sciences · doi:10.7150/ijms.3635 · Cited by 2,880
Exploring treatment options in cancer: tumor treatment strategies
Liu, B., Zhou, H., Tan, L., Siu, K. T. H., & Guan, X.-Y. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01856-7 · Cited by 1,201
Gold nanoparticles for applications in cancer radiotherapy: Mechanisms and recent advancements
Her, S., Jaffray, D. A., & Allen, C. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.12.012 · Cited by 865
Charged particles in radiation oncology
Durante, M., & Loeffler, J. S. (2010) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2009.183 · Cited by 737
Primary radiation damage: A review of current understanding and models
Nordlund, K., Zinkle, S. J., Sand, A. E., Granberg, F., Averback, R. S., Stoller, R. E., Suzudo, T., Malerba, L., Banhart, F., Weber, W. J., et al. (2018) · Journal of Nuclear Materials · doi:10.1016/j.jnucmat.2018.10.027 · Cited by 681
Heavy ion carcinogenesis and human space exploration
Durante, M., & Cucinotta, F. A. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2391 · Cited by 578
Carbon ion radiotherapy in Japan: an assessment of 20 years of clinical experience
Kamada, T., Tsujii, H., Blakely, E. A., Debus, J., De Neve, W., Durante, M., Jäkel, O., Mayer, R., Orecchia, R., Pötter, R., et al. (2015) · The Lancet Oncology · doi:10.1016/s1470-2045(14)70412-7 · Cited by 562
Self-citationStrategies for optimizing the response of cancer and normal tissues to radiation
Moding, E. J., Kastan, M. B., & Kirsch, D. G. (2013) · Nature Reviews Drug Discovery · doi:10.1038/nrd4003 · Cited by 461
Charged particle therapy—optimization, challenges and future directions
Loeffler, J. S., & Durante, M. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.79 · Cited by 426
Assessing the risk of second malignancies after modern radiotherapy
Newhauser, W. D., & Durante, M. (2011) · Nature Reviews Cancer · doi:10.1038/nrc3069 · Cited by 380
Elsässer, T., Weyrather, W. K., Friedrich, T., Durante, M., Iancu, G., Krämer, M., Kragl, G., Brons, S., Winter, M., Weber, K.-J., et al. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.05.014 · Cited by 351
Nuclear physics in particle therapy: a review
Durante, M., & Paganetti, H. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/9/096702 · Cited by 345
Proton vs carbon ion beams in the definitive radiation treatment of cancer patients
Suit, H., DeLaney, T., Goldberg, S., Paganetti, H., Clasie, B., Gerweck, L., Niemierko, A., Hall, E., Flanz, J., Hallman, J., et al. (2010) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2010.01.015 · Cited by 290
Liauw, S. L., Connell, P. P., & Weichselbaum, R. R. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005148 · Cited by 257
Sridharan, D. M., Asaithamby, A., Bailey, S. M., Costes, S. V., Doetsch, P. W., Dynan, W. S., Kronenberg, A., Rithidech, K. N., Saha, J., Snijders, A. M., et al. (2015) · Radiation Research · doi:10.1667/rr13804.1 · Cited by 124
Risks of cognitive detriments after low dose heavy ion and proton exposures
Cucinotta, F. A., & Cacao, E. (2019) · International Journal of Radiation Biology · doi:10.1080/09553002.2019.1623427 · Cited by 58
Metadata
- Authors
- Schulz-Ertner, D., & Tsujii, H.
- Venue
- Journal of Clinical Oncology
- Published
- 2007-03-10
- Volume
- 25
- Issue
- 8
- Pages
- 953-964
- ISSN
- 0732-183X (ISSN-L)
- 1527-7755
- OpenAlex
- W2098443648
- Cited by
- 622
- References
- 37
- FWCI
- 35.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.