Ultrasound for Breast Cancer Detection Globally: A Systematic Review and Meta-Analysis
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
PURPOSE: Mammography is not always available or feasible. The purpose of this systematic review and meta-analysis is to assess the diagnostic performance of ultrasound as a primary tool for early detection of breast cancer. MATERIALS AND METHODS: For this systematic review and meta-analysis, we comprehensively searched PubMed and SCOPUS to identify articles from January 2000 to December 2018 that included data on the performance of ultrasound for detection of breast cancer. Studies evaluating portable, handheld ultrasound as an independent detection modality for breast cancer were included. Quality assessment and bias analysis were performed with the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity analyses and meta-regression were used to explore heterogeneity. The study protocol has been registered with the international prospective register of systematic reviews (PROSPERO identifier: CRD42019127752). RESULTS: Of the 526 identified studies, 26 were eligible for inclusion. Ultrasound had an overall pooled sensitivity and specificity of 80.1% (95% CI, 72.2% to 86.3%) and 88.4% (95% CI, 79.8% to 93.6%), respectively. When only low- and middle-income country data were considered, ultrasound maintained a diagnostic sensitivity of 89.2% and specificity of 99.1%. Meta-analysis of the included studies revealed heterogeneity. The high sensitivity of ultrasound for the detection of breast cancer was not statistically significantly different in subgroup analyses on the basis of mean age, risk, symptoms, study design, bias level, and study setting. CONCLUSION: Given the increasing burden of breast cancer and infeasibility of mammography in certain settings, we believe these results support the potential use of ultrasound as an effective primary detection tool for breast cancer, which may be beneficial in low-resource settings where mammography is unavailable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bray, F., Ferlay, J., Soerjomataram, I., Siegel, R. L., Torre, L. A., & Jemal, A. (2018) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21492 · Cited by 84,109 · cited 2×
“8, respectively.(1) It is estimated that by 2020, 70% of all breast cancer cases worldwide will occur in LMICs, with a projected estimate to more than 1 million new cases per year in these areas.”
BackgroundGlobal cancer statistics, 2012
Torre, L. A., Bray, F., Siegel, R. L., Ferlay, J., Lortet‐Tieulent, J., & Jemal, A. (2015) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21262 · Cited by 26,850
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Duval, S., & Tweedie, R. (2000) · Biometrics · doi:10.1111/j.0006-341x.2000.00455.x · Cited by 14,099 · cited 1×
“To account for presence of possibly missing studies, the trim and fill method was used to obtain the adjusted DORs for both ultrasound and mammography.(24) To assess for possible improvement in ultrasound technology over the years, regression analysis of the DORs was performed and trended across publication years of t…”
MethodA basic introduction to fixed-effect and random-effects models for meta-analysis
Borenstein, M., Hedges, L. V., Higgins, J. P. T., & Rothstein, H. R. (2010) · Research Synthesis Methods · doi:10.1002/jrsm.12 · Cited by 6,793
Global Cancer Incidence and Mortality Rates and Trends—An Update
Torre, L. A., Siegel, R. L., Ward, E. M., & Jemal, A. (2016) · Cancer Epidemiology, Biomarkers & Prevention · doi:10.1158/1055-9965.epi-15-0578 · Cited by 3,692 · cited 2×
“In 2012, 52.9% of the 1.7 million breast cancer cases were classified as global, and 62.1% of the breast cancer–related deaths occurred in LMICs.10 Although breast cancer incidence is highest in high-income countries, mortality rates are lower in these locations as a result of advances in early detection, diagnosis, a…”
BackgroundInfluentialHow should meta‐regression analyses be undertaken and interpreted?
Thompson, S. G., & Higgins, J. P. T. (2002) · Statistics in Medicine · doi:10.1002/sim.1187 · Cited by 3,026 · cited 1×
“Heterogeneity was investigated with calculated Higgins I(2) values, with greater than 50% considered indicative of substantial heterogeneity among studies.(18) Forest plots were drawn to visually represent S cr ee n in g”
MethodDeeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910 · cited 1×
“1 considered statistically significant.(22,23) To account for presence of possibly missing studies, the trim and fill method was used to obtain the adjusted DORs for both ultrasound and mammography.”
MethodKolb, T. M., Lichy, J., & Newhouse, J. H. (2002) · Radiology · doi:10.1148/radiol.2251011667 · Cited by 1,718 · cited 1×
“Six studies took place in mammographically negative population subsets.(25,44,45,47-49) In regard to study design, 15 were prospective and nine were retrospective.”
BackgroundA hierarchical regression approach to meta‐analysis of diagnostic test accuracy evaluations
Rutter, C. M., & Gatsonis, C. A. (2001) · Statistics in Medicine · doi:10.1002/sim.942 · Cited by 1,505
Kuhl, C. K., Schrading, S., Leutner, C. C., Morakkabati-Spitz, N., Wardelmann, E., Fimmers, R., Kuhn, W., & Schild, H. H. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2004.00.4960 · Cited by 1,147
Conducting systematic reviews of diagnostic studies: didactic guidelines
Devillé, W. L., Buntinx, F., Bouter, L. M., Montori, V. M., de Vet, H. C., van der Windt, D. A., & Bezemer, P. D. (2002) · BMC Medical Research Methodology · doi:10.1186/1471-2288-2-9 · Cited by 960
Lehman, C. D., Arao, R. F., Sprague, B. L., Lee, J. M., Buist, D. S. M., Kerlikowske, K., Henderson, L. M., Onega, T., Tosteson, A. N. A., Rauscher, G. H., et al. (2017) · Radiology · doi:10.1148/radiol.2016161174 · Cited by 665
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Anderson, B. O., Yip, C.-H., Smith, R. A., Shyyan, R., Sener, S. F., Eniu, A., Carlson, R. W., Azavedo, E., & Harford, J. (2008) · Cancer · doi:10.1002/cncr.23844 · Cited by 533 · cited 2×
“Because patients in LMICs often present with locally advanced disease and have a younger average age at diagnosis, there is impetus for using ultrasound as the first imaging modality in these areas.(11) The findings from this study on the diagnostic utility of ultrasound may therefore be most viable in these settings.”
Warner, E., Plewes, D. B., Shumak, R. S., Catzavelos, G. C., Di Prospero, L. S., Yaffe, M. J., Goel, V., Ramsay, E., Chart, P. L., Cole, D. E. C., et al. (2001) · Journal of Clinical Oncology · doi:10.1200/jco.2001.19.15.3524 · Cited by 461 · cited 1×
“Two were crosssectional in nature (Table 1).(30,38) From the 26 studies reporting findings on the use of ultrasound as a detection modality for breast cancer, the pooled sensitivity, specificity, DOR, positive predictive value, and NPV (95% CI) were 80.”
BackgroundLehman, C. D., Isaacs, C., Schnall, M. D., Pisano, E. D., Ascher, S. M., Weatherall, P. T., Bluemke, D. A., Bowen, D. J., Marcom, P. K., Armstrong, D. K., et al. (2007) · Radiology · doi:10.1148/radiol.2442060461 · Cited by 396
Nothacker, M., Duda, V., Hahn, M., Warm, M., Degenhardt, F., Madjar, H., Weinbrenner, S., & Albert, U.-S. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-335 · Cited by 314 · cited 1×
“Ultrasound is a particularly useful diagnostic modality in dense breast tissue, often detecting breast cancers obscured on mammography.(8,9) Furthermore, if biopsy is required, ultrasound is the ideal imaging tool to guide subsequent procedures, further enhancing its utility in breast cancer diagnosis.”
BackgroundUltrasound as the Primary Screening Test for Breast Cancer: Analysis From ACRIN 6666
Berg, W. A., Bandos, A. I., Mendelson, E. B., Lehrer, D., Jong, R. A., & Pisano, E. D. (2016) · Journal of the National Cancer Institute · doi:10.1093/jnci/djv367 · Cited by 309
Yip, C.-H., Smith, R. A., Anderson, B. O., Miller, A. B., Thomas, D. B., Ang, E.-S., Caffarella, R. S., Corbex, M., Kreps, G. L., McTiernan, A., et al. (2008) · Cancer · doi:10.1002/cncr.23842 · Cited by 301
Breast cancer screening in developing countries
da Costa Vieira, R. A., Biller, G., Uemura, G., Ruiz, C. A., & Curado, M. P. (2017) · Clinics · doi:10.6061/clinics/2017(04)09 · Cited by 293 · cited 2×
“5%, respectively.(3,4) In low- and middle-income countries (LMICs), the reported sensitivity of mammography ranges from 63% to 95%; higher sensitivity is seen when examining palpable lumps, and lower sensitivity is seen in cases of dense breasts.”
BackgroundHow to assess publication bias: funnel plot, trim-and-fill method and selection models
Mavridis, D., & Salanti, G. (2014) · Evidence Based Mental Health · doi:10.1136/eb-2013-101699 · Cited by 268 · cited 1×
“1 considered statistically significant.(22,23) To account for presence of possibly missing studies, the trim and fill method was used to obtain the adjusted DORs for both ultrasound and mammography.”
MethodShen, S., Zhou, Y., Xu, Y., Zhang, B., Duan, X., Huang, R., Li, B., Shi, Y., Shao, Z., Liao, H., et al. (2015) · British Journal of Cancer · doi:10.1038/bjc.2015.33 · Cited by 190 · cited 1×
“women tend to have dense breast tissue and a younger peak age of breast cancer incidence, making ultrasound a potentially more accurate breast cancer detection modality in this population.(34) In addition, women presenting with late-stage disease and symptoms are known to represent the largest proportion of the women…”
BackgroundBreast Cancer Detected with Screening US: Reasons for Nondetection at Mammography
Bae, M. S., Moon, W. K., Chang, J. M., Koo, H. R., Kim, W. H., Cho, N., Yi, A., La Yun, B., Lee, S. H., Kim, M. Y., et al. (2014) · Radiology · doi:10.1148/radiol.13130724 · Cited by 174 · cited 1×
“Ultrasound is a particularly useful diagnostic modality in dense breast tissue, often detecting breast cancers obscured on mammography.(8,9) Furthermore, if biopsy is required, ultrasound is the ideal imaging tool to guide subsequent procedures, further enhancing its utility in breast cancer diagnosis.”
BackgroundThigpen, D., Kappler, A., & Brem, R. F. (2018) · Diagnostics · doi:10.3390/diagnostics8010020 · Cited by 164
Rebolj, M., Assi, V., Brentnall, A. R., Parmar, D., & Duffy, S. W. (2018) · British Journal of Cancer · doi:10.1038/s41416-018-0080-3 · Cited by 160
Silber, J. H., Rosenbaum, P. R., Ross, R. N., Reiter, J. G., Niknam, B. A., Hill, A. S., Bongiorno, D. M., Shah, S. A., Hochman, L. L., Even‐Shoshan, O., et al. (2018) · Milbank Quarterly · doi:10.1111/1468-0009.12355 · Cited by 148 · cited 1×
“In addition, women presenting with late-stage disease and symptoms are known to represent the largest proportion of the women presenting for breast cancer concerns in LMICs or low-resource regions of high-income countries.(55,56) Because patients in LMICs often present with locally advanced disease and have a younger…”
BackgroundLehman, C. D., Lee, C. I., Loving, V. A., Portillo, M., Peacock, S., & DeMartini, W. B. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.12.8842 · Cited by 134 · cited 1×
“In addition, numerous studies report high sensitivity and NPV up to 100%when ultrasound is used for cancer detection at the site of focal breast symptoms.(42,54) However, there is limited information on the value of ultrasound as an early detection tool in primarily asymptomatic women.”
BackgroundBirnbaum, J. K., Duggan, C., Anderson, B. O., & Etzioni, R. (2018) · The Lancet Global Health · doi:10.1016/s2214-109x(18)30257-2 · Cited by 126 · cited 1×
“In addition, women presenting with late-stage disease and symptoms are known to represent the largest proportion of the women presenting for breast cancer concerns in LMICs or low-resource regions of high-income countries.(55,56) Because patients in LMICs often present with locally advanced disease and have a younger…”
BackgroundSprague, B. L., Arao, R. F., Miglioretti, D. L., Henderson, L. M., Buist, D. S. M., Onega, T., Rauscher, G. H., Lee, J. M., Tosteson, A. N. A., Kerlikowske, K. M., et al. (2017) · Radiology · doi:10.1148/radiol.2017161519 · Cited by 125 · cited 2×
“5%, respectively.(3,4) In low- and middle-income countries (LMICs), the reported sensitivity of mammography ranges from 63% to 95%; higher sensitivity is seen when examining palpable lumps, and lower sensitivity is seen in cases of dense breasts.”
BackgroundBreast Cancer in Limited-Resource Countries: Diagnosis and Pathology
Shyyan, R., Masood, S., Badwe, R. A., Errico, K. M., Liberman, L., Özmen, V., Stalsberg, H., Vargas, H., Vass, L., & Panel, F. T. G. S. D. A. P. (2006) · The Breast Journal · doi:10.1111/j.1075-122x.2006.00201.x · Cited by 112 · cited 1×
“The Breast Health Global Initiative advocates for the introduction of diagnostic ultrasound at the resource-limited level, given that it is more widely available than mammography in these countries and extremely useful in women with palpable lesions.(57) For example, in Uganda, where organized breast health programs a…”
BackgroundLoving, V. A., DeMartini, W. B., Eby, P. R., Gutierrez, R. L., Peacock, S., & Lehman, C. D. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4396 · Cited by 60 · cited 1×
“In addition, numerous studies report high sensitivity and NPV up to 100%when ultrasound is used for cancer detection at the site of focal breast symptoms.(42,54) However, there is limited information on the value of ultrasound as an early detection tool in primarily asymptomatic women.”
BackgroundHou, M., Chuang, H., Ou‐Yang, F., Wang, C.-Y., Huang, C.-L., Fan, H.-M., Chuang, C., Wang, J., Hsieh, J., Liu, G., et al. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00483-0 · Cited by 53
Breast cancer screening in a resource poor country: Ultrasound versus mammography
Omidiji, O. A. T., Campbell, P. C., Irurhe, N., Atalabi, O. M., & Toyobo, O. O. (2017) · Ghana Medical Journal · doi:10.4314/gmj.v51i1.2 · Cited by 50 · cited 1×
“Two were crosssectional in nature (Table 1).(30,38) From the 26 studies reporting findings on the use of ultrasound as a detection modality for breast cancer, the pooled sensitivity, specificity, DOR, positive predictive value, and NPV (95% CI) were 80.”
BackgroundLeong, L. C. H., Gogna, A., Pant, R., Ng, F., & Sim, L. S. J. (2012) · Annals of the Academy of Medicine Singapore · doi:10.47102/annals-acadmedsg.v41n10p432 · Cited by 44 · cited 1×
“Six studies took place in mammographically negative population subsets.(25,44,45,47-49) In regard to study design, 15 were prospective and nine were retrospective.”
BackgroundBreast Cancer—Thinking Globally
Anderson, B. O. (2014) · Science · doi:10.1126/science.1253344 · Cited by 41 · cited 1×
“It is estimated that by 2020, 70% of all breast cancer cases worldwide will occur in LMICs, with a projected estimate to more than 1 million new cases per year in these areas.(5,13) These disproportionately high mortality-to-incidence ratios in LMICs are due to scarcity of available detection, diagnosis, and treatment…”
BackgroundPilot Study of a Resource-Appropriate Strategy for Downstaging Breast Cancer in Rural Uganda
Matovu, A., Scheel, J. R., Shadrack, P., Africa, I. T. W., Ssembatya, R., Africa, I. T. W., Njeri, A., Galukande, M., & DeStigter, K. K. (2016) · Journal of Global Radiology · doi:10.7191/jgr.2016.1021 · Cited by 15
Pilot Educational Intervention and Feasibility Assessment of Breast Ultrasound in Rural South Africa
Dickerson, L. K., Rositch, A. F., Lucas, S. M., & Harvey, S. C. (2017) · Journal of Global Oncology · doi:10.1200/jgo.2016.008086 · Cited by 15 · cited 1×
“There is evidence this can be achieved on a small scale and could be scalable.(59) In conclusion, on the basis of the existing literature, our review demonstrates ultrasound has the potential to yield high sensitivity and specificity for breast cancer detection.”
BackgroundSelf-citation
Cited by
The future of early cancer detection
Fitzgerald, R. C., Antoniou, A. C., Fruk, L., & Rosenfeld, N. (2022) · Nature Medicine · doi:10.1038/s41591-022-01746-x · Cited by 457
Jabeen, K., Khan, M. A., Alhaisoni, M., Tariq, U., Zhang, Y.-D., Hamza, A., Mickus, A., & Damaševičius, R. (2022) · Sensors · doi:10.3390/s22030807 · Cited by 314
“In dense breast tissue, ultrasound is a highly powerful diagnostic tool, often finding breast tumors that are missed by mammography [13].”
BackgroundCurrent State of Breast Cancer Diagnosis, Treatment, and Theranostics
Bhushan, A., Gonsalves, A., & Menon, J. U. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13050723 · Cited by 298
Shen, Y., Shamout, F. E., Oliver, J. R., Witowski, J., Kannan, K., Park, J., Wu, N., Huddleston, C., Wolfson, S., Millet, A., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-26023-2 · Cited by 270
Omics Technologies Improving Breast Cancer Research and Diagnostics
Orsini, A., Diquigiovanni, C., & Bonora, E. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms241612690 · Cited by 52
“Ultrasound is more adaptable, portable and affordable than a mammogram, but it also depends on the operator’s skill [187].”
Background
Metadata
- Authors
- Sood, R., Rositch, A. F., Shakoor, D., Ambinder, E., Pool, K.-L., Pollack, E., Mollura, D. J., Mullen, L. A., & Harvey, S. C.
- Venue
- Journal of Global Oncology
- Published
- 2019-12
- Volume
- 5
- Issue
- 5
- Pages
- 1-17
- ISSN
- 2378-9506 (ISSN-L)
- OpenAlex
- W2970196304
- Cited by
- 251
- References
- 38
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.