Nanomedicine, Volume IIA
Abstract
The safety, effectiveness, and utility of medical nanorobotic devices will critically depend upon their biocompatibility with human organs, tissues, cells, and biochemical systems. In this Volume, we broaden the definition of nanomedical biocompatibility to include all of the mechanical, physiological, immunological, cytological, and biochemical re
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Advanced nanomedicine - specifically, medical nanorobotics - is expected to serve as a dynamic tool toward addressing most human brain disorders.
“The pursuit of ever smaller tools to treat patients is approaching a pivotal juncture in medical history as advanced nanomedicine — specifically, medical nanorobotics — is expected to serve as a dynamic tool toward addressing most human brain disorders.”
From Human Brain/Cloud Interface (2019) · cites this paper as Freitas, 2003
Autonomous nanomedical devices are expected to be biocompatible, primarily due to their structural materials, which would enable extended residency within the human body.
“Furthermore, autonomous nanomedical devices are expected to be biocompatible, primarily due to their structural materials, which would enable extended residency within the human body”
From Human Brain/Cloud Interface (2019) · cites this paper as Freitas, 2003
In cases where there is a complete absence of large BBB junctional gaps, mission-designed strategies, including a combination of cytopenetration, cytolocomotion, and histonatation, would likely permit access to the neuropil.
“However, in cases where there is a complete absence of large BBB junctional gaps, mission-designed strategies, including a combination of cytopenetration, cytolocomotion, and histonatation, would likely permit access to the neuropil (Freitas, 1999b, 2003, 2016).”
From Human Brain/Cloud Interface (2019) · cites this paper as Freitas, 2003
Neural electrodes can be implanted without producing any detectable damage beyond the initial trauma and brief phagocytosis, typically limited to the edges of the electrode insertion pathway.
“Neural electrodes can be implanted without producing any detectable damage beyond the initial trauma and brief phagocytosis, which are typically limited to the edges of the electrode insertion pathway (Babb and Kupfer, 1984) (Freitas, 2003).”
From Human Brain/Cloud Interface (2019) · cites this paper as Freitas, 2003
Total volume displaced by endoneurobots and gliabots would be ∼0.12% of a "typical" ∼14,000 μm3 neuron volume, which is orders of magnitude below the total 1-10% "safe" tissue and organ intrusiveness limit for nanorobots that has been recommended elsewhere.
“Thus, total volume displaced by endoneurobots and gliabots would be ∼0.12% of a “typical” ∼14,000 μm3 neuron volume, which is orders of magnitude below the total 1–10% “safe” tissue and organ intrusiveness limit for nanorobots that has been recommended elsewhere (Freitas, 2003).”
From Human Brain/Cloud Interface (2019) · cites this paper as Freitas, 2003
Cited by
Sorted by citations
Existential Risk Prevention as Global Priority
Bostrom, N. (2013) · Global Policy · doi:10.1111/1758-5899.12002 · Cited by 588 · see citing works
Chronic interfacing with the autonomic nervous system using carbon nanotube (CNT) yarn electrodes
McCallum, G. A., Sui, X., Qiu, C., Marmerstein, J., Zheng, Y., Eggers, T. E., Hu, C., Dai, L., & Durand, D. M. (2017) · Scientific Reports · doi:10.1038/s41598-017-10639-w · Cited by 102 · see citing works
Martins, N. R. B., Angelica, A., Chakravarthy, K., Svidinenko, Y., Boehm, F. J., Opris, I., Lebedev, M. A., Swan, M., Garan, S. A., Rosenfeld, J. V., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00112 · Cited by 91 · see citing works
Self-citationKundu, A., Wirenfeldt, M., Harreby, K. R., & Jensen, W. (2014) · The International Journal of Artificial Organs · doi:10.5301/ijao.5000342 · Cited by 15 · see citing works
- Authors
- Freitas, R. A.
- Corresponding author
- Freitas, Robert A.
- ORCID
- Freitas, Robert A.
- Venue
- CRC Press eBooks
- Publisher
- CRC Press
- Published
- 2003-09-26
- OpenAlex
- W4210281108
- Cited by
- 91
- References
- 0
- Citations by year
- 2024: 2 · 2023: 1 · 2022: 3 · 2021: 1 · 2020: 3 · 2019: 4 · 2018: 3 · 2017: 4 · 2016: 7 · 2015: 3 · 2014: 2 · 2013: 5 · 2012: 5
- Type
- reference entry
- Language
- en
- Open access
- closed
- Locations
- CRC Press eBooks (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Micro and Nano Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Nanotechnology research and applications
- Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
- Keywords
- nanomedicine, biocompatibility, medical nanorobots, immunological safety, machine safety
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review