Validity of Seven Commercially Available Heart Rate Monitors
The DOI matches its Crossref record.
Abstract
Heart rate monitors have been marketed as an accurate way to measure heart rate. This investigation was designed to determine the validity of seven different types of heart rate monitors. Fourteen men (19.6 ± 2.3 years, 77.7 ±7.1 kg) participated in the study. Heart rate was measured simultaneously for 10 sec during minute 9 -10 of rest or during exercise on a treadmill at 85.7 m · min-1, 107.3 m · min-1, and 160.8 m · min-1. Pearson product-moment correlation (r) and standard error of estimate (SEE) were calculated between an electrocardiogram (ECG) measurement and the measurement of heart rate from each of the 7 heart rate monitors. The POLAR Vantage XL, POLAR Accurex II, Cardiochamp, and the Cateye-PL 6000 heart rate monitors accurately assessed heart rates (r ⪈ 0.90, SEE £ 5 beats · min-1) during rest and at moderate activity. At the highest speed, the accuracy decreased, leading us to caution the heart rate monitor user regarding the validity of any of these monitors at high heart rates and motion levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Practical Guide to Measuring Physical Activity
Sylvia, L. G., Bernstein, E. E., Hubbard, J. L., Keating, L., & Anderson, E. J. (2014) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2013.09.018 · Cited by 637
The Reliability of MinimaxX Accelerometers for Measuring Physical Activity in Australian Football
Boyd, L. J., Ball, K., & Aughey, R. J. (2011) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.6.3.311 · Cited by 556
Accuracy of wrist-worn heart rate monitors
Wang, R., Blackburn, G., Desai, M., Phelan, D., Gillinov, L., Houghtaling, P., & Gillinov, M. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.3340 · Cited by 386
Wearable Performance Devices in Sports Medicine
Li, R. T., Kling, S. R., Salata, M. J., Cupp, S. A., Sheehan, J., & Voos, J. E. (2016) · Sports Health: A Multidisciplinary Approach · doi:10.1177/1941738115616917 · Cited by 348
Variable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise
GILLINOV, S., ETIWY, M., WANG, R., BLACKBURN, G., PHELAN, D., GILLINOV, A. M., HOUGHTALING, P., JAVADIKASGARI, H., & DESAI, M. Y. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001284 · Cited by 345
Wearable sensors for monitoring the internal and external workload of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0149-2 · Cited by 330
Wearable and Implantable Sensors for Biomedical Applications
Koydemir, H. C., & Ozcan, A. (2018) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061417-125956 · Cited by 289
Stahl, S. E., An, H.-S., Dinkel, D. M., Noble, J. M., & Lee, J.-M. (2016) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2015-000106 · Cited by 276
“During the late 1980s and 1990s, HR monitoring during physical activity (PA) continued to grow in popularity, and by the early 2000s, there were as many as 26 different models available to the recreational athlete.(2) In the past 5 years, HR monitoring devices have been combined with other activity monitors, such as p…”
Evaluation of wearable consumer heart rate monitors based on photopletysmography
Parak, J., & Korhonen, I. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944419 · Cited by 148
Gorny, A. W., Liew, S. J., Tan, C. S., & Müller-Riemenschneider, F. (2017) · JMIR mHealth and uHealth · doi:10.2196/mhealth.8233 · Cited by 94
“Moreover, devices that have been shown to track heart rates reliably, such as Polar [12,13] and Actiheart [14,15], by measuring myocardial electric potentials (akin to an electrocardiogram), are cumbersome to wear over extended periods as they need to be strapped across the chest.”
BackgroundValidation of a Photoplethysmographic Heart Rate Monitor: Polar OH1
Hermand, E., Cassirame, J., Ennequin, G., & Hue, O. (2019) · International Journal of Sports Medicine · doi:10.1055/a-0875-4033 · Cited by 59
Continuous heart rhythm monitoring using mobile photoplethysmography in ambulatory patients
Hochstadt, A., Havakuk, O., Chorin, E., Schwartz, A. L., Merdler, I., Laufer, M., Lubman, N., Ghantous, E., Viskin, S., & Rosso, R. (2020) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2020.04.017 · Cited by 18
The impact of the COVID-19 pandemic on the diet, training habits and fitness of Masters cyclists
Shaw, K. A., Bertrand, L., Deprez, D., Ko, J., Zello, G. A., & Chilibeck, P. D. (2022) · Nutrition and Health · doi:10.1177/02601060211002350 · Cited by 12
Metadata
- Authors
- Terbizan, D. J., Dolezal, B. A., & Albano, C.
- Venue
- Measurement in Physical Education and Exercise Science
- Publisher
- Informa UK Limited
- Published
- 2002-12
- Volume
- 6
- Issue
- 4
- Pages
- 243-247
- ISSN
- 1091-367X (ISSN-L)
- 1532-7841
- OpenAlex
- W2087560482
- Cited by
- 141
- References
- 0
- FWCI
- 0.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.