Advances in Metered Dose Inhaler Technology: Formulation Development
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
US Environmental Protection Agency
(1998) · Choice Reviews Online · doi:10.5860/choice.35-4455 · Cited by 5,897
Stratospheric sink for chlorofluoromethanes: chlorine atom-catalysed destruction of ozone
Molina, M. J., & Rowland, F. S. (1974) · Nature · doi:10.1038/249810a0 · Cited by 4,332 · cited 9×
“Variability in dose delivery for suspension formulations can be caused by, among other things, (1) variable drug concentration because of drug deposition on the canister or valve surfaces, and (2) variable sampling of the formulation by the valve because of flocculation and creaming/ settling (152).”
InfluentialAlexandridis, P., & Alan Hatton, T. (1995) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/0927-7757(94)03028-x · Cited by 1,920
International programme on chemical safety
Haines, J. (1996) · The Lancet · doi:10.1016/s0140-6736(05)65029-5 · Cited by 1,869
Calculation of HLB Values of Non-ionic Surfactants
Griffin, W. C. (1954) · Cited by 1,344
Formulation strategy and use of excipients in pulmonary drug delivery
Pilcer, G., & Amighi, K. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.03.017 · Cited by 791 · cited 3×
“and precipitation of particles from gas saturated solutions (90).”
InfluentialParticle Engineering for Pulmonary Drug Delivery
Chow, A. H. L., Tong, H. H. Y., Chattopadhyay, P., & Shekunov, B. Y. (2007) · Pharmaceutical Research · doi:10.1007/s11095-006-9174-3 · Cited by 645 · cited 1×
“'s (87) articles for an extensive review of the topic.”
Influence of particle size on regional lung deposition – What evidence is there?
Carvalho, T. C., Peters, J. I., & Williams III, R. O. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.12.040 · Cited by 614 · cited 1×
“5 and 5 μm are delivered to the lungs, and smaller particles are more likely to deposit in the deep lung compared to larger particles (6).”
Dry Powder Inhaler Formulation
Telko, M. J., & Hickey, A. J. (2005) · Respiratory Care · doi:10.4187/respcare.05501209 · Cited by 498 · cited 1×
“This method is relatively slow and is difficult to scale up (91).”
Leach, C., Davidson, P., & Boudreau, R. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12061346 · Cited by 430 · cited 1×
“With a small residual particle size, it is expected that a greater extent of the drug deposits in the peripheral airways (airway diameters, ≤2 mm), compared with a CFC BDP formulation with a residual size of approximately 3 μm (74), which primarily deposited in the central airways (78).”
Cited by
Drug Delivery to the lungs: Challenges and Opportunities
Newman, S. P. (2017) · Therapeutic Delivery · doi:10.4155/tde-2017-0037 · Cited by 328
Metadata
- Authors
- Myrdal, P. B., Sheth, P., & Stein, S. W.
- Venue
- AAPS PharmSciTech
- Published
- 2014-01-23
- Volume
- 15
- Issue
- 2
- Pages
- 434-455
- ISSN
- 1530-9932 (ISSN-L)
- OpenAlex
- W2077722212
- Cited by
- 184
- References
- 48
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.