Advances in Metered Dose Inhaler Technology: Formulation Development
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
US Environmental Protection Agency
(1998) · Choice Reviews Online · doi:10.5860/choice.35-4455 · Cited by 5,897
Stratospheric sink for chlorofluoromethanes: chlorine atom-catalysed destruction of ozone
Molina, M. J., & Rowland, F. S. (1974) · Nature · doi:10.1038/249810a0 · Cited by 4,332 · cited 9×
“Variability in dose delivery for suspension formulations can be caused by, among other things, (1) variable drug concentration because of drug deposition on the canister or valve surfaces, and (2) variable sampling of the formulation by the valve because of flocculation and creaming/ settling (152).”
InfluentialAlexandridis, P., & Alan Hatton, T. (1995) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/0927-7757(94)03028-x · Cited by 1,920
International programme on chemical safety
Haines, J. (1996) · The Lancet · doi:10.1016/s0140-6736(05)65029-5 · Cited by 1,869
Calculation of HLB Values of Non-ionic Surfactants
Griffin, W. C. (1954) · Cited by 1,344
Formulation strategy and use of excipients in pulmonary drug delivery
Pilcer, G., & Amighi, K. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.03.017 · Cited by 791 · cited 3×
“and precipitation of particles from gas saturated solutions (90).”
InfluentialParticle Engineering for Pulmonary Drug Delivery
Chow, A. H. L., Tong, H. H. Y., Chattopadhyay, P., & Shekunov, B. Y. (2007) · Pharmaceutical Research · doi:10.1007/s11095-006-9174-3 · Cited by 645 · cited 1×
“'s (87) articles for an extensive review of the topic.”
Influence of particle size on regional lung deposition – What evidence is there?
Carvalho, T. C., Peters, J. I., & Williams III, R. O. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.12.040 · Cited by 614 · cited 1×
“5 and 5 μm are delivered to the lungs, and smaller particles are more likely to deposit in the deep lung compared to larger particles (6).”
Dry Powder Inhaler Formulation
Telko, M. J., & Hickey, A. J. (2005) · Respiratory Care · doi:10.4187/respcare.05501209 · Cited by 498 · cited 1×
“This method is relatively slow and is difficult to scale up (91).”
Leach, C., Davidson, P., & Boudreau, R. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12061346 · Cited by 430 · cited 1×
“With a small residual particle size, it is expected that a greater extent of the drug deposits in the peripheral airways (airway diameters, ≤2 mm), compared with a CFC BDP formulation with a residual size of approximately 3 μm (74), which primarily deposited in the central airways (78).”
The large contribution of projected HFC emissions to future climate forcing
Velders, G. J. M., Fahey, D. W., Daniel, J. S., McFarland, M., & Andersen, S. O. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0902817106 · Cited by 424 · cited 1×
“propellants contributed approximately 3% of total emissions of CO2 equivalents in 2007 (34); of those emissions, less than 2% is due to MDIs, resulting in a minimal contribution of HFA MDIs to global warming (35).”
Development of an Inhaled Dry-Powder Formulation of Tobramycin Using PulmoSphere™ Technology
Geller, D. E., Weers, J., & Heuerding, S. (2011) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2010.0855 · Cited by 308 · cited 1×
“While, no PulmoSphere MDI formulations have been approved, Tobi Podhaler, a dry powder inhaler PulmoSphere tobramycin formulation, was approved in Europe in 2010 (151).”
Particle engineering techniques for inhaled biopharmaceuticals
Shoyele, S. A., & Cawthorne, S. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.07.010 · Cited by 301 · cited 2×
“While particle engineering for inhalation drug products is briefly discussed below, please refer to Shoyele and Cawthorne's (86) and Chow et al.”
Busse, W. W., Brazinsky, S., Jacobson, K., Stricker, W., Schmitt, K., Vanden Burgt, J., Donnell, D., Hannon, S., & Colice, G. L. (1999) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(99)70016-3 · Cited by 260
Principles of Metered-Dose Inhaler Design
Newman, S. P. (2005) · Respiratory Care · doi:10.4187/respcare.05501177 · Cited by 244 · cited 1×
“CFCs 11 and 114 mainly functioned to modify the vapor pressure of CFC 12 and to facilitate manufacturing when used in formulations with propellant blends (10).”
MethodControlled Pulmonary Drug Delivery
(2011) · Springer eBooks · doi:10.1007/978-1-4419-9745-6 · Cited by 231
The environmental impact of CFC replacements - HFCs and HCFCs
Wallington, T. J., Schneider, W. F., Worsnop, D. R., Nielsen, O. J., Sehested, J., Debruyn, W. J., & Shorter, J. A. (1994) · Environmental Science & Technology · doi:10.1021/es00056a002 · Cited by 198 · cited 1×
“The extensive destruction of the ozone by CFCs is due to two factors: (1) the chemical stability under ambient environmental conditions and low aqueous solubility of CFCs result in long lifespans of these chemicals that permit ample time for CFC molecules to diffuse into the upper atmosphere (11) and (2) once in the s…”
Hollow Porous Particles in Metered Dose Inhalers
Dellamary, L. A., Tarara, T. E., Smith, D. J., Woelk, C. H., Adractas, A., Costello, M. L., Gill, H., & Weers, J. G. (2000) · Pharmaceutical Research · doi:10.1023/a:1007513213292 · Cited by 179 · cited 3×
“PulmoSpheres can be engineered to enable delivery of a broad range of drug concentrations (10 μg of fomoterol fumerate to 1 mg of cromolyn sodium) with decreased rate of phase separation and particle aggregation over a period of hours compared to commercial Intal CFC (commercial cromolyn sodium formulation) and Proven…”
Dry powder formulations for pulmonary delivery
Malcolmson, R. J., & Embleton, J. K. (1998) · Pharmaceutical Science & Technology Today · doi:10.1016/s1461-5347(98)00099-6 · Cited by 178
Inactive ingredient Search for Approved Drug Products
(2018) · Cited by 161
Smyth, H. D. C. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(03)00079-6 · Cited by 159 · cited 24×
“where ν is the sedimentation velocity (such that ν>0 is in the direction of gravity), g is the gravitational acceleration constant, dp is the diameter of the suspended particle, ρp is the density of the suspended particle, ρform is the density of the formulation, and η is the viscosity of the formulation (7).”
InfluentialCFC and Halon replacements in the environment
McCulloch, A. (1999) · Journal of Fluorine Chemistry · doi:10.1016/s0022-1139(99)00198-0 · Cited by 125 · cited 2×
“a Relative to CFC 11 Represents 100-year global warming potential relative to CO2 c Source: Vervaet and Byron (8) d Source: Smyth (7) e Source: McCulloch (9) 436 Myrdal et al.”
Challenges with Developing In Vitro Dissolution Tests for Orally Inhaled Products (OIPs)
Riley, T., Christopher, D., Arp, J., Casazza, A., Colombani, A., Cooper, A. D., Dey, M., Maas, J., Mitchell, J. P., Reiners, M., et al. (2012) · AAPS PharmSciTech · doi:10.1208/s12249-012-9822-3 · Cited by 115 · cited 1×
“These excipients may also alter the dissolution of residual particles from the aerosol spray in the lungs, which results in modulating the pharmacological effect (52,53).”
Transition to CFC-free metered dose inhalers — into the new millennium
McDonald, K. J., & Martin, G. P. (2000) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(00)00401-4 · Cited by 109
Longest, P. W., & Hindle, M. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2011.566592 · Cited by 97 · cited 2×
“Hygroscopic growth depends on the hygroscopicity of the excipient and the drug, the properties of the engineered particle, and the respiratory parameters (100).”
The CFC to HFA Transition and Its Impact on Pulmonary Drug Development
Leach, C. (2005) · Respiratory Care · doi:10.4187/respcare.05501201 · Cited by 76 · cited 1×
“Both propellants have excellent safety profiles (31) and are chemically stable under normal storage conditions (25).”
Stein, S. W., & Myrdal, P. B. (2006) · Aerosol Science and Technology · doi:10.1080/02786820600612268 · Cited by 76 · cited 15×
“The microparticles are optimized for aerodynamic properties while designed to be ideal cosuspending agents for 450 Myrdal et al. conventional drug crystals within suspension MDIs.”
InfluentialSelf-citationKaerger, J. S., & Price, R. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000016252.97296.f1 · Cited by 74 · cited 1×
“One such method currently being investigated involves tailored particle engineering by cocrystallizing two or more drugs (160).”
Barnes, N. C., Price, D. B., Colice, G., Chisholm, A., Dorinsky, P., Hillyer, E. V., Burden, A., Lee, A. J., Martin, R. J., Roche, N., et al. (2011) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.2011.03820.x · Cited by 72 · cited 1×
“Treating the peripheral airways is important especially for a large proportion of asthmatic patients who experience persistent small airway dysfunction (77) and has been shown to improve the probability of patients achieving asthma control over a period of 1 year (81).”
Leach, C., Kuehl, P. J., Chand, R., Ketai, L. H., Norenberg, J. P., & McDonald, J. D. (2012) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2012.01.010 · Cited by 59 · cited 1×
“, patients do not need to shake the vial immediately prior to use and there is no concern related to sampling homogeneity), a finer residual aerosol (47) and potentially larger fine particle doses (i.”
Butz, N., Porté, C., Courrier, H. M., Krafft, M. P., & Vandamme, T. F. (2002) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(02)00086-8 · Cited by 58 · cited 1×
“Others have formed reverse emulsions using fluorine moieties, such as perfluorooctyl bromide with perfluoroalkylated dimorpholinophosphate (a fluorinated surfactant) (141) or polar fluorinated nonionic oxyethylene glycol with ethanol, propanol or pentanol as a cosolvent (142).”
Crosslinked chitosan nanoparticle formulations for delivery from pressurized metered dose inhalers
Sharma, K., Somavarapu, S., Colombani, A., Govind, N., & Taylor, K. M. G. (2012) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2011.12.014 · Cited by 52
Price, D. B., Thomas, M. D., Haughney, J., Lewis, R. A., Burden, A., von Ziegenweidt, J., Chisholm, A., Hillyer, E. V., & Corrigan, C. J. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2013.03.009 · Cited by 52 · cited 1×
“The extrafine aerosol formulation approach permits QVAR to have a lower formulation drug concentration, increased inhalation technique tolerance and increased ratio of therapeutic efficacy to adverse effects because of the deposition of the drug in the peripheral airways compared to the CFC formulation (79,80).”
Liao, Y., Brown, M. B., Jones, S. A., Nazir, T., & Martin, G. P. (2005) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2005.07.013 · Cited by 50 · cited 1×
“(93,94), trehalose with polyvinyl alcohol (95), and/or polyvi-”
Noakes, T. (2002) · Journal of Fluorine Chemistry · doi:10.1016/s0022-1139(02)00191-4 · Cited by 49 · cited 1×
“However, many of the conventional excipients used in CFC formulations and approved for human use, are insoluble in HFA systems (49).”
Investigation of a pMDI system containing chitosan microspheres and P134a
Williams, R. O., Barron, M. K., Alonso, M. J., & Remuñán‐López, C. (1998) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(98)00266-x · Cited by 48 · cited 1×
“Alternatively, chitosan microspheres have been investigated to protect and afford sustained release of proteins and plasmid nucleic acids via MDI drug delivery (101); the addition of glycerol to solution BDP MDI formulations has shown to affect the extent of drug metabolism across a cell layer, suggesting increased re…”
Targeting the small airways asthma phenotype: if we can reach it, should we treat it?
Lipworth, B. J. (2013) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2013.02.009 · Cited by 39
Sommerville, M. L., Cain, J. B., Johnson, C. S., & Hickey, A. J. (2000) · Pharmaceutical Development and Technology · doi:10.1081/pdt-100100537 · Cited by 38 · cited 1×
“01% (w/w) in HFAs 134a and 227 (8)), it is soluble in dimethyl ether and propane propellant systems, and can be utilized to form water-in-oil (inverse) microemulsions that further stabilize suspension formulations (22,120).”
Wu, L., Bharatwaj, B., Panyam, J., & da Rocha, S. R. P. (2007) · Pharmaceutical Research · doi:10.1007/s11095-007-9466-2 · Cited by 35 · cited 1×
“One approach is to use suspended core–shell particles in HFA, where the particles are made by emulsification diffusion (138).”
Formulation of a protein with propellant HFA 134a for aerosol delivery
Williams, R. O., & Liu, J. (1999) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(98)00015-3 · Cited by 34 · cited 1×
“Additionally, they are completely miscible in one another and vapor pressure upon mixing behaves ideally, thus they may be blended in different proportions to obtain a specific vapor pressure or density (30).”
James, J., Crean, B., Davies, M. C., Toon, R. C., Jinks, P., & Roberts, C. J. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.05.032 · Cited by 33 · cited 2×
“, sodium chloride); however, most research has been conducted with α-lactose monohydrate (153,154).”
Wu, L., Al-Haydari, M. D., & da Rocha, S. R. P. (2007) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2007.10.007 · Cited by 32 · cited 1×
“, PEG) moieties (137) at the surface of polar drug particles using a modified emulsification–diffusion method.”
Rogueda, P., Price, R., Smith, T., Young, P. M., & Traini, D. (2011) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2011.05.073 · Cited by 30 · cited 1×
“were found to be quite different, based on atomic force microscopy and Raman spectroscopy (162).”
Tuning Aerosol Particle Size Distribution of Metered Dose Inhalers Using Cosolvents and Surfactants
Saleem, I. Y., & Smyth, H. D. C. (2013) · BioMed Research International · doi:10.1155/2013/574310 · Cited by 26 · cited 2×
“Similar results were also foundwith amodel drug (fluorescein sodium) andHFA 227 (59).”
Tan, Y., Yang, Z., Peng, X., Xin, F., Xu, Y., Feng, M., Zhao, C., Hu, H., & Wu, C. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2011.03.069 · Cited by 25 · cited 1×
“(98), as described under the subheading “Particle Preparation for MDI Formulations” within this”
Polymers for Pulmonary Drug Delivery
Sheth, P., & Myrdal, P. B. (2011) · Springer eBooks · doi:10.1007/978-1-4419-9745-6_12 · Cited by 18
Self-citationO’Donnell, K. P., & Williams, R. O. (2012) · Drug Development and Industrial Pharmacy · doi:10.3109/03639045.2012.664145 · Cited by 13 · cited 4×
“However, the ethyl acetate solvate of BDP experiences minimal growth when exposed to CFC 11 (103).”
InfluentialScience and Technology of Pressurized Metered-Dose Inhalers
da Rocha, S. R. P., Bharatwaj, B., & Saiprasad, S. (2011) · Springer eBooks · doi:10.1007/978-1-4419-9745-6_8 · Cited by 10
Cited by
Drug Delivery to the lungs: Challenges and Opportunities
Newman, S. P. (2017) · Therapeutic Delivery · doi:10.4155/tde-2017-0037 · Cited by 328
Metadata
- Authors
- Myrdal, P. B., Sheth, P., & Stein, S. W.
- Venue
- AAPS PharmSciTech
- Published
- 2014-01-23
- Volume
- 15
- Issue
- 2
- Pages
- 434-455
- ISSN
- 1530-9932 (ISSN-L)
- OpenAlex
- W2077722212
- Cited by
- 184
- References
- 48
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.