High-accuracy measurement of the 87 Rb ground-state hyperfine splitting in an atomic fountain
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We describe the operation of a laser-cooled rubidium 87 Rb frequency standard. We present a new measurement of the 87 Rb hyperfine frequency with a 1.3 × 10 −14 relative accuracy, by comparison with a Cs fountain primary standard. The measured 87 Rb ground-state hyperfine splitting is ν 87 = 6 834 682 610.90429(9) Hz. This value differs from previously published values (see Essen L., Hope E. G. and Sutcliffe D., Nature 189 1961 298; Penselin S., Moran T., Cohen W. and Wscinkler G., Phys. Rev. 127 1962 524; Arditi M. and Cerez P. IEEE Trans. Instrum. Meas. IM-21 1972 391) by about 2 − 3 Hz and is 10 4 times more accurate. Because of the low collisional shift in 87 Rb, future improvements may lead to a stability of 1 × 10 −14 τ −1/2 and a relative accuracy in the 10 −17 range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Cited by
Quantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard
Santarelli, G., Laurent, P., Lemonde, P., Clairon, A., Mann, A. G., Chang, S., Luiten, A. N., & Salomon, C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.4619 · Cited by 569
Self-citationSoffel, M., Klioner, S. A., Petit, G., Wolf, P., Kopeikin, S. M., Bretagnon, P., Brumberg, V. A., Capitaine, N., Damour, T., Fukushima, T., et al. (2003) · The Astronomical Journal · doi:10.1086/378162 · Cited by 392
“In the near future, high-accuracy laser-cooled rubidium clocks (Bize et al. 1999) and spaceborne cesium clocks (Lemonde et al. 2001) are expected to reach accuracies of a few parts in 1017 in fractional frequency and stabilities on the order of y( ) = 1 10 14 1/2.”
BackgroundWynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
Atomic gravitational wave interferometric sensor
Dimopoulos, S., Graham, P. W., Hogan, J. M., Kasevich, M. A., & Rajendran, S. (2008) · Physical Review D · doi:10.1103/physrevd.78.122002 · Cited by 335
Correlations and Counting Statistics of an Atom Laser
Öttl, A., Ritter, S., Köhl, M., & Esslinger, T. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.090404 · Cited by 328
Metadata
- Authors
- Bize, S., Sortais, Y., Santos, M. S., Mandache, C., Clairon, A., & Salomon, C.
- Venue
- Europhysics Letters (EPL)
- Publisher
- IOP Publishing
- Published
- 1999-03-01
- Volume
- 45
- Issue
- 5
- Pages
- 558-564
- ISSN
- 0295-5075 (ISSN-L)
- 1286-4854
- OpenAlex
- W2052617183
- Cited by
- 162
- References
- 1
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.