High-accuracy measurement of the 87 Rb ground-state hyperfine splitting in an atomic fountain
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
We describe the operation of a laser-cooled rubidium 87 Rb frequency standard. We present a new measurement of the 87 Rb hyperfine frequency with a 1.3 × 10 −14 relative accuracy, by comparison with a Cs fountain primary standard. The measured 87 Rb ground-state hyperfine splitting is ν 87 = 6 834 682 610.90429(9) Hz. This value differs from previously published values (see Essen L., Hope E. G. and Sutcliffe D., Nature 189 1961 298; Penselin S., Moran T., Cohen W. and Wscinkler G., Phys. Rev. 127 1962 524; Arditi M. and Cerez P. IEEE Trans. Instrum. Meas. IM-21 1972 391) by about 2 − 3 Hz and is 10 4 times more accurate. Because of the low collisional shift in 87 Rb, future improvements may lead to a stability of 1 × 10 −14 τ −1/2 and a relative accuracy in the 10 −17 range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The string dilation and a least coupling principle
Damour, T., & Polyakov, A. M. (1994) · Nuclear Physics B · doi:10.1016/0550-3213(94)90143-0 · Cited by 1,233
Experimental determinations of the hyperfine structure in the alkali atoms
Arimondo, E., Inguscio, M., & Violino, P. (1977) · Reviews of Modern Physics · doi:10.1103/revmodphys.49.31 · Cited by 1,004
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Atomic Clocks and Variations of the Fine Structure Constant
Prestage, J. D., Tjoelker, R. L., & Maleki, L. (1995) · Physical Review Letters · doi:10.1103/physrevlett.74.3511 · Cited by 298
Gibble, K., & Chu, S. (1993) · Physical Review Letters · doi:10.1103/physrevlett.70.1771 · Cited by 263
Ramsey Resonance in a Zacharias Fountain
Clairon, A., Salomon, C., Guellati, S., & Phillips, W. D. (1991) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/16/2/008 · Cited by 223
Self-citationShift ofS122hyperfine splittings due to blackbody radiation
Itano, W. M., Lewis, L. L., & Wineland, D. J. (1982) · Physical Review A · doi:10.1103/physreva.25.1233 · Cited by 219
Laser-Cooled Mercury Ion Frequency Standard
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.2089 · Cited by 196
A cesium fountain frequency standard: preliminary results
Clairon, A., Laurent, P., Santarelli, G., Ghezali, S., Lea, S. N., & Bahoura, M. (1995) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.377790 · Cited by 171
Self-citationOptical Detection of Narrow Rb87 Hyperfine Absorption Lines
Bender, P., Beaty, E. C., & R., A. (1958) · Physical Review Letters · doi:10.1103/physrevlett.1.311 · Cited by 159
Cited by
Quantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard
Santarelli, G., Laurent, P., Lemonde, P., Clairon, A., Mann, A. G., Chang, S., Luiten, A. N., & Salomon, C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.4619 · Cited by 569
Self-citationSoffel, M., Klioner, S. A., Petit, G., Wolf, P., Kopeikin, S. M., Bretagnon, P., Brumberg, V. A., Capitaine, N., Damour, T., Fukushima, T., et al. (2003) · The Astronomical Journal · doi:10.1086/378162 · Cited by 392
“In the near future, high-accuracy laser-cooled rubidium clocks (Bize et al. 1999) and spaceborne cesium clocks (Lemonde et al. 2001) are expected to reach accuracies of a few parts in 1017 in fractional frequency and stabilities on the order of y( ) = 1 10 14 1/2.”
BackgroundWynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
Atomic gravitational wave interferometric sensor
Dimopoulos, S., Graham, P. W., Hogan, J. M., Kasevich, M. A., & Rajendran, S. (2008) · Physical Review D · doi:10.1103/physrevd.78.122002 · Cited by 335
Correlations and Counting Statistics of an Atom Laser
Öttl, A., Ritter, S., Köhl, M., & Esslinger, T. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.090404 · Cited by 328
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Self-citationProgress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Self-citationScalable Spin Squeezing for Quantum-Enhanced Magnetometry with Bose-Einstein Condensates
Muessel, W., Strobel, H., Linnemann, D., Hume, D. B., & Oberthaler, M. K. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.103004 · Cited by 254
Compact Optical Atomic Clock Based on a Two-Photon Transition in Rubidium
Martin, K. W., Phelps, G., Lemke, N. D., Bigelow, M. S., Stuhl, B., Wojcik, M., Holt, M., Coddington, I., Bishop, M. W., & Burke, J. H. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.9.014019 · Cited by 169
“[18, 36] yields a second order state shift of 114 Hz/G(2) for (87)Rb (F=2) and 358 Hz/G(2) for (85)Rb (F=3).”
BackgroundTakekoshi, T., Debatin, M., Rameshan, R., Ferlaino, F., Grimm, R., Nägerl, H.-C., Le Sueur, C. R., Hutson, J. M., Julienne, P. S., Kotochigova, S., et al. (2012) · Physical Review A · doi:10.1103/physreva.85.032506 · Cited by 159
Relativistic theory for time and frequency transfer to order $\vec {c}^{-3}$
Blanchet, L., Salomon, C., Teyssandier, P., & Wolf, P. (2001) · Astronomy & Astrophysics · doi:10.1051/0004-6361:20010233 · Cited by 132
“…cooling of atoms have led to the development of a number of highly accurate atomic clocks (Caesium and Rubidium fountains) which have improved time-keeping accuracy by an order of magnitude during the nineties to currently ≈10−15 in fractional frequency (Laurent et al. 1999; Bize et al. 1999).”
BackgroundSelf-citation
Metadata
- Authors
- Bize, S., Sortais, Y., Santos, M. S., Mandache, C., Clairon, A., & Salomon, C.
- Venue
- Europhysics Letters (EPL)
- Publisher
- IOP Publishing
- Published
- 1999-03-01
- Volume
- 45
- Issue
- 5
- Pages
- 558-564
- ISSN
- 0295-5075 (ISSN-L)
- 1286-4854
- OpenAlex
- W2052617183
- Cited by
- 162
- References
- 19
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.