CoChat

Comparison of Diagnostic Accuracy of Urinary Free Metanephrines, Vanillyl Mandelic Acid, and Catecholamines and Plasma Catecholamines for Diagnosis of Pheochromocytoma

Open access
Boyle, James G., Davidson, D. Fraser, Perry, Colin G., Connell, John M. C. · 2007 · The Journal of Clinical Endocrinology & Metabolism
Cited by 120

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Context: Recent evidence suggests that plasma-free metanephrines provide a highly sensitive test in patients requiring exclusion of pheochromocytoma. The diagnostic efficacy of urinary free metanephrines, however, has not been evaluated. Objective, Design, Setting, Patients, and Outcome Measures: We compared retrospectively the diagnostic efficacy of 24-h urinary free metanephrines with our currently available measurements of 24-h urinary vanillyl mandelic acid (VMA), urinary catecholamines, and plasma catecholamines in 159 outpatients tested in a tertiary referral center for pheochromocytoma over a 4-yr period. Results: The sensitivity of urinary free metanephrines was 100% [25 of 25 patients; 95% confidence interval (CI) 86–100%)] compared with the sensitivity of 84% (21 of 25; 95% CI 64–95%) for urinary catecholamines; 72% (18 of 25; 95% CI 51–88%) for urinary VMA; and 76% (16 of 21; 95% CI 53–92%) for plasma catecholamines. The specificity of urinary free metanephrines was 94% (116 of 123; 95% CI 89–98%), compared with the specificity of 99% (127 of 129; 95% CI 96–100%) for urinary catecholamines; 96% (130 of 134; 95% CI 91–98%) for urinary VMA; and 88% (66 of 75; 95% CI 78–94%) for plasma catecholamines. Receiver operating characteristic curves for all test groups were generated. Pairwise comparisons of the area under the receiver operating characteristic curve for urinary free metanephrines with that of each of the other three test groups individually were: 0.993 (95% CI 0.962–0.999) vs. 0.919 (95% CI 0.862–0.957, P = 0.032) for urine catecholamines; 0.993 (95% CI 0.962–0.999) vs. 0.846 (95% CI 0.778–0.900, P = 0.002) for urine VMA; and 0.992 (95% CI 0.945–0.998) vs. 0.852 (95% CI 0.762–0.918, P = 0.009) for plasma catecholamines. Testing with urinary free metanephrines failed to misidentify a single case of pheochromocytoma, compared with four missed cases for urinary catecholamines, seven missed cases for urinary VMA, and five missed cases for plasma catecholamines. Conclusion: Urinary free metanephrines were superior to urinary VMA, urinary catecholamines, and plasma catecholamines and can provide a valuable test for diagnosis of pheochromocytoma in adults.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2005-2668

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 120

Metadata

Authors
Boyle, J. G., Davidson, D. F., Perry, C. G., & Connell, J. M. C.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2007-12-01
Volume
92
Issue
12
Pages
4602-4608
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2088515136
Cited by
120
References
3
FWCI
7.03
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Diagnostic Accuracy of Urinary Free Metanephrines, Vanillyl Mandelic Acid, and Catecholamines and Plasma Catecholamines for Diagnosis of Pheochromocytoma. https://app.cochat.ai/papers/10.1210/jc.2005-2668
The paper
Boyle, J. G., Davidson, D. F., Perry, C. G., & Connell, J. M. C. (2007). Comparison of Diagnostic Accuracy of Urinary Free Metanephrines, Vanillyl Mandelic Acid, and Catecholamines and Plasma Catecholamines for Diagnosis of Pheochromocytoma. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2005-2668

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.