CoChat

Diagnostic Characteristics of Late-Night Salivary Cortisol Using Liquid Chromatography-Tandem Mass Spectrometry

Open access
Zerikly, R. Kurdi, Amiri, L., Faiman, C., Gupta, M., Singh, R. J., Nutter, B., Kennedy, L., Hatipoglu, B., Weil, R. J., Hamrahian, A. H. · 2010 · The Journal of Clinical Endocrinology & Metabolism
Cited by 48

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The objective of the study was to describe the diagnostic performance of a commercially available late-night salivary cortisol (NSC) assay using liquid chromatography tandem mass spectrometry. METHODS: We retrospectively identified 90 patients who had one or more NSC determinations: 52 patients in whom Cushing syndrome (CS) was excluded or could not be confirmed [group 1 (G1)] and 38 patients in whom CS was confirmed [group 2 (G2)]. Eighteen healthy volunteers served as controls. RESULTS: Baseline demographics in all groups were similar with regards to age, ethnicity, gender, and body mass index. NSC levels [median (range)] were higher in G2, 381 (64-13,500) ng/dl [10.51 (1.77-372.46) nmol/liter], compared with controls, 19.3 (2.1-416) ng/dl [0.53 (0.06-11.48) nmol/liter], and G1, 26 (4-176) ng/dl [0.72 (0.11-4.86) nmol/liter, P < 0.001]. The highest combined sensitivity (92%) and specificity (92%) was achieved at a cut point of 107 ng/dl (2.95 nmol/liter). Two or more NSCs were done in 32 of 52 G1 and 31 of 38 G2 patients. In G1 eight of 32 (25%) had at least one elevated [>100 ng/dl (2.76 nmol/liter)] NSC including two in whom both NSCs were elevated. In contrast, four of 31 (13%) in G2 had at least one normal NSC including one with four of five normal NSC values. None of the patients with CS had a NSC less than 60 ng/dl (<1.66 nmol/liter). Comparing G1 and G2, obtaining more than one saliva sample did not improve the diagnostic accuracy of NSC measurement (P = 0.64). CONCLUSION: The liquid chromatography tandem mass spectrometry assay to measure NSC is a simple and reliable test to screen patients suspected to have CS. Clinicians should be aware of appropriate cutoff values for proper interpretation of NSC and use additional tests when necessary.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2009-2458

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 48

Metadata

Authors
Zerikly, R. K., Amiri, L., Faiman, C., Gupta, M., Singh, R. J., Nutter, B., Kennedy, L., Hatipoglu, B., Weil, R. J., & Hamrahian, A. H.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2010-10
Volume
95
Issue
10
Pages
4555-4559
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2021837773
Cited by
48
References
11
FWCI
3.74
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Characteristics of Late-Night Salivary Cortisol Using Liquid Chromatography-Tandem Mass Spectrometry. https://app.cochat.ai/papers/10.1210/jc.2009-2458
The paper
Zerikly, R. K., Amiri, L., Faiman, C., Gupta, M., Singh, R. J., Nutter, B., Kennedy, L., Hatipoglu, B., Weil, R. J., & Hamrahian, A. H. (2010). Diagnostic Characteristics of Late-Night Salivary Cortisol Using Liquid Chromatography-Tandem Mass Spectrometry. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2009-2458

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.