Salivary cortisol and cortisone by LC–MS/MS: validation, reference intervals and diagnostic accuracy in Cushing's syndrome

Antonelli, Giorgia, Ceccato, Filippo, Artusi, Carlo, Marinova, Mariela, Plebani, Mario·2015·Clinica Chimica Acta

Abstract

Background The Endocrine Society recommends late-night salivary cortisol (LNS-F) as a first-line screening test for Cushing's syndrome (CS). In the parotid gland, 11β-hydroxysteroid dehydrogenase type 2 inactivates cortisol (F) to cortisone (E), a known source of interference in the more frequently used immunoassays. A highly specific method is mandatory in determining salivary F and E: it is widely accepted that liquid chromatography-tandem mass spectrometry (LC-MS/MS) is the best available technique for this purpose.Methods A LC-MS/MS method with SPE of saliva samples was developed and validated. Appropriate awakening and bedtime reference ranges were established. The diagnostic performance for F, E and the ratio at bedtime was evaluated in 25 cases of CS.Results The method was linear, with up to 55.4 nmol/L and 51.0 nmol/L, LLOQ of 0.51 nmol/L and 0.55 nmol/L, for F and E, respectively. Within-run and between-run imprecisions were <10% for both analytes. No ion suppression was observed. A cut-off of 2.4 nmol/L for LNS-F yielded a sensitivity of 100% and a specificity of 98% in the diagnosis of CS.Conclusions The analytical performance of this method justifies its introduction into clinical practice, thus allowing clinicians the opportunity to further investigate CS and other endocrine diseases.

Integrity signals

Registry

Crossref · 10.1016/j.cca.2015.10.004

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

1 of the 36 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Antonelli, G., Ceccato, F., Artusi, C., Marinova, M., & Plebani, M.
Affiliations
University of Padua (IT)
Corresponding author
Antonelli, Giorgia
Venue
Clinica Chimica Acta
Publisher
Elsevier BV
Published
2015-12
Volume
451
Issue
Pt B
Pages
247-251
ISSN
0009-8981 (ISSN-L)
OpenAlex
W1839948300
Cited by
111
References
36
Citations by year
2026: 6 · 2025: 10 · 2024: 8 · 2023: 8 · 2022: 8 · 2021: 11 · 2020: 13 · 2019: 13 · 2018: 12 · 2017: 14 · 2016: 7 · 2015: 1
FWCI
9.83
Type
journal article
Language
en
Open access
closed
Locations
  • Clinica Chimica Acta (publishedVersion)
  • PubMed (publishedVersion)
  • Padua Research Archive (University of Padova) (submittedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pituitary Gland Disorders and Treatments
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
Keywords
Cushing's syndrome, salivary cortisol, salivary cortisone, late-night salivary cortisol, LC-MS/MS method validation, 11β-hydroxysteroid dehydrogenase type 2, diagnostic accuracy, reference values, screening test
MeSH terms
Adult, Aged, Aged, 80 and over, Chromatography, High Pressure Liquid, Cortisone, Cushing Syndrome, Female, Humans, Hydrocortisone, Male, Middle Aged, Reference Values, Saliva, Tandem Mass Spectrometry, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review