CoChat

Salivary Cortisone Reflects Cortisol Exposure Under Physiological Conditions and After Hydrocortisone

Debono, Miguel, Harrison, Robert F., Whitaker, Martin J., Eckland, David, Arlt, Wiebke, Keevil, Brian G., Ross, Richard J. · 2016 · The Journal of Clinical Endocrinology & Metabolism

The DOI matches its Crossref record; 30 of the 31 references it cites were found in a registry or an index.

Abstract

Context: Measuring serum cortisol to evaluate stress, adrenal disease, and monitor hydrocortisone replacement requires venepuncture. Conversely, salivary measurements are noninvasive. Objective: This study aimed to investigate measurement of salivary cortisol and cortisone as alternatives to serum cortisol. Design and Setting: This was a prospective cross-over study in a clinical research facility. Patients and Methods: Over three periods (Period 1, 24-h physiological cortisol rhythm; Periods 2 and 3, after 20 mg oral and iv hydrocortisone) 14 male volunteers had serum and saliva cortisol and cortisone, serum albumin, cortisol-binding globulin, and free cortisol measured. Data were analyzed for rhythm parameters and correlations. Linear mixed-effects modelling was performed to determine the relationship between serum cortisol and salivary cortisone. Results: Serum cortisol and cortisone showed similar circadian rhythms with large peak:trough ratios (cortisol median ratio, 11). Albumin and cortisol-binding globulin showed minor peak:trough ratios <1.2. When serum cortisol was <74 (SD, 29) nmol/L, salivary cortisol was not detectable but salivary cortisone was always detected. Salivary cortisol post-oral hydrocortisone produced spurious results due to contamination. Under physiological conditions, salivary cortisone correlated strongly with serum cortisol (ρ, 0.91; 95% confidence interval, 0.89–0.93; P < .001). Similarly, following iv or oral hydrocortisone, salivary cortisone correlated strongly with serum cortisol (ρ, 0.91; 95% confidence interval, 0.89–0.92; P < .001). A mixed-effects model showed that in this population 94% of the variation in salivary cortisone could be predicted from serum cortisol. Conclusion: Salivary cortisol is frequently undetectable and contaminated by oral hydrocortisone. In contrast, salivary cortisone reflects serum cortisol and provides a noninvasive alternative to measuring serum cortisol levels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2015-3694

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

8 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

Items 101–128 of 128

Metadata

Authors
Debono, M., Harrison, R. F., Whitaker, M. J., Eckland, D., Arlt, W., Keevil, B. G., & Ross, R. J.
Affiliations
  • University of Sheffield (GB)
  • Diurnal (United Kingdom) (GB)
  • University of Birmingham (GB)
  • Department of Clinical Biochemistry (B.G.K.), University Hospital South Manchester, Manchester M23 9LT, United Kingdom
Corresponding author
Ross, Richard J.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2016-04-01
Volume
101
Issue
4
Pages
1469-1477
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2269039627
Cited by
128
References
31
Citations by year
2026: 14 · 2025: 13 · 2024: 16 · 2023: 21 · 2022: 8 · 2021: 10 · 2020: 16 · 2019: 9 · 2018: 8 · 2017: 9 · 2016: 4
FWCI
10.04
Type
journal article
Language
en
Open access
closed
Locations
  • The Journal of Clinical Endocrinology & Metabolism (publishedVersion)
  • PubMed (publishedVersion)
  • White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
  • University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
  • Spiral (Imperial College London) (submittedVersion)
Funders
  • National Institute for Health and Care Research (CL-2013-04-001)
  • European Commission (281654)
  • University of Sheffield
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
  • Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
Keywords
salivary cortisone, salivary cortisol, serum cortisol, cortisol, diurnal cortisol rhythm, corticosteroid-binding globulin, albumin, free cortisol, sample contamination
MeSH terms
Adult, Chromatography, Liquid, Circadian Rhythm, Cortisone, Humans, Hydrocortisone, Male, Prospective Studies, Saliva, Salivary Glands, Cross-Over Studies, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.