Salivary Cortisone Reflects Cortisol Exposure Under Physiological Conditions and After Hydrocortisone
The DOI matches its Crossref record; 30 of the 31 references it cites were found in a registry or an index.
Abstract
Context: Measuring serum cortisol to evaluate stress, adrenal disease, and monitor hydrocortisone replacement requires venepuncture. Conversely, salivary measurements are noninvasive. Objective: This study aimed to investigate measurement of salivary cortisol and cortisone as alternatives to serum cortisol. Design and Setting: This was a prospective cross-over study in a clinical research facility. Patients and Methods: Over three periods (Period 1, 24-h physiological cortisol rhythm; Periods 2 and 3, after 20 mg oral and iv hydrocortisone) 14 male volunteers had serum and saliva cortisol and cortisone, serum albumin, cortisol-binding globulin, and free cortisol measured. Data were analyzed for rhythm parameters and correlations. Linear mixed-effects modelling was performed to determine the relationship between serum cortisol and salivary cortisone. Results: Serum cortisol and cortisone showed similar circadian rhythms with large peak:trough ratios (cortisol median ratio, 11). Albumin and cortisol-binding globulin showed minor peak:trough ratios <1.2. When serum cortisol was <74 (SD, 29) nmol/L, salivary cortisol was not detectable but salivary cortisone was always detected. Salivary cortisol post-oral hydrocortisone produced spurious results due to contamination. Under physiological conditions, salivary cortisone correlated strongly with serum cortisol (ρ, 0.91; 95% confidence interval, 0.89–0.93; P < .001). Similarly, following iv or oral hydrocortisone, salivary cortisone correlated strongly with serum cortisol (ρ, 0.91; 95% confidence interval, 0.89–0.92; P < .001). A mixed-effects model showed that in this population 94% of the variation in salivary cortisone could be predicted from serum cortisol. Conclusion: Salivary cortisol is frequently undetectable and contaminated by oral hydrocortisone. In contrast, salivary cortisone reflects serum cortisol and provides a noninvasive alternative to measuring serum cortisol levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Ninety-four percent of the variation in serum cortisol is predicted from changes in salivary cortisone”
From Bioavailability of Oral Hydrocortisone Corrected for Binding Proteins and Measured by LC-MS/MS Using Serum Cortisol and Salivary Cortisone (2018) · cites this paper as [6]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Analysis by LC-MS/MS can separately measure salivary cortisol and cortisone in the same sample, at the same time, and at no incremental cost.24”
From Home waking salivary cortisone to screen for adrenal insufficiency (2023) · cites this paper as [24]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Salivary cortisone has been shown to correlate better with plasma free cortisol than salivary cortisol and to be less susceptible to preanalytical confounders (20, 23, 27, 28).”
From Salivary Cortisol and Cortisone Can Circumvent Confounding Effects of Oral Contraceptives in the Short Synacthen Test (2024) · cites this paper as [28]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Salivary cortisol and cortisone both show a close relationship to serum cortisol and serum free cortisol [6,7].”
From Bioavailability of Oral Hydrocortisone Corrected for Binding Proteins and Measured by LC-MS/MS Using Serum Cortisol and Salivary Cortisone (2018) · cites this paper as [6]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“the presence of HSD11B2 in the parotid gland makes salivary cortisone a useful marker for serum free cortisol and adrenal stimulation [[211], [212], [213]].”
From Human steroid biosynthesis, metabolism and excretion are differentially reflected by serum and urine steroid metabolomes: a comprehensive review (2019) · cites this paper as [212]
Experimental — accuracy not yet measured
8 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The diagnosis of Cushing's syndrome: an Endocrine Society Clinical Practice Guideline.
Nieman, L. K., Biller, B. M. K., Findling, J. W., Newell-Price, J., Savage, M. O., Stewart, P. M., & Montori, V. M. (2008) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-0125 · Cited by 2,718 · cited 2×
“They are therefore used extensively in hospital laboratories (22), are an ideal tool for researchers, and the measurement of salivary cortisol has been recommended in major guidelines (3).”
BackgroundMethod11β-Hydroxysteroid dehydrogenase type 1: a tissue specific regulator of glucocorticoid response
Tomlinson, J. W., Walker, E. A., Bujalska, I. J., Draper, N., Lavery, G. G., Cooper, M. S., Hewison, M., & Stewart, P. M. (2004) · Endocrine Reviews · doi:10.1210/er.2003-0031 · Cited by 969
Tissue effects of glucocorticoids
Baxter, J. D., & Forsham, P. H. (1972) · The American Journal of Medicine · doi:10.1016/0002-9343(72)90154-4 · Cited by 503 · cited 1×
“It is important to consider the transport of cortisol in the circulation when measuring serum cortisol; 80% is bound to cortisol-binding globulin (CBG), 10% to albumin, and approximately 10% is free cortisol (unbound fraction), the latter providing biological activity (8).”
BackgroundKumari, M., Shipley, M., Stafford, M., & Kivimaki, M. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2137 · Cited by 343 · cited 1×
“A flattened diurnal cortisol slope is associated with cardiovascular mortality (23), type 2 diabetes (24), and obesity (25).”
BackgroundModified-release hydrocortisone to provide circadian cortisol profiles
Debono, M., Ghobadi, C., Rostami-Hodjegan, A., Huatan, H., Campbell, M. J., Newell-Price, J., Darzy, K., Merke, D. P., Arlt, W., & Ross, R. J. (2009) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-2380 · Cited by 322
Self-citationHypertension and the cortisol-cortisone shuttle
Quinkler, M., & Stewart, P. M. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030138 · Cited by 286 · cited 1×
“This conversion of cortisol to cortisone predominantly reflects the function of 11 -HSD2 in the kidneys as it protects the mineralocorticoid receptor from excess active cortisol by converting it to inactive cortisone (20).”
BackgroundSalivary cortisone is a potential biomarker for serum free cortisol
Perogamvros, I., Keevil, B. G., Ray, D. W., & Trainer, P. J. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-1215 · Cited by 222 · cited 18×
“irrespective of elevations in CBG (14) but detailed mod-”
BackgroundInfluentialSelf-citationMeasurement of salivary cortisol in 2012 – laboratory techniques and clinical indications
Inder, W. J., Dimeski, G., & Russell, A. (2012) · Clinical Endocrinology · doi:10.1111/j.1365-2265.2012.04508.x · Cited by 195 · cited 1×
“In contrast, the measurement of salivary cortisol is relatively noninvasive and convenient for the patient because it can be done at home and mailed to the laboratory (5).”
BackgroundAn assessment of optimal hydrocortisone replacement therapy
Howlett, T. A. (1997) · Clinical Endocrinology · doi:10.1046/j.1365-2265.1997.1340955.x · Cited by 169 · cited 5×
“1474 Debono et al Salivary Cortisone J Clin Endocrinol Metab, April 2016, 101(4):1469–1477”
BackgroundInfluentialNovel liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for measuring steroids
Keevil, B. G. (2013) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2013.05.015 · Cited by 157 · cited 1×
“They are therefore used extensively in hospital laboratories (22), are an ideal tool for researchers, and the measurement of salivary cortisol has been recommended in major guidelines (3).”
BackgroundSelf-citationLocalization of 11 beta-hydroxysteroid dehydrogenase type II in human epithelial tissues.
Smith, R. E., Maguire, J. A., Stein-Oakley, A. N., Sasano, H., Takahashi, K., Fukushima, K., & Krozowski, Z. S. (1996) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.81.9.8784076 · Cited by 146 · cited 1×
“The enzyme 11 -hydroxysteroid dehydrogenase type 2 (11 -HSD2) is expressed in the salivary glands and rapidly inactivates cortisol by conversion to cortisone (13).”
BackgroundKumari, M., Chandola, T., Brunner, E., & Kivimaki, M. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2009-2105 · Cited by 141 · cited 1×
“A flattened diurnal cortisol slope is associated with cardiovascular mortality (23), type 2 diabetes (24), and obesity (25).”
BackgroundPerogamvros, I., Owen, L. J., Newell-Price, J., Ray, D. W., Trainer, P. J., & Keevil, B. G. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.09.014 · Cited by 140 · cited 5×
“The introduction of LCMS/MS has further increased the sensitivity and specificity of the assays and allows the simultaneous measurement of both salivary cortisol and cortisone (6).”
BackgroundMethodInfluentialSelf-citationBright, G. M. (1995) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.80.3.7883829 · Cited by 137 · cited 14×
“We found that CBG and albumin showed a circadian rhythm that was out of phase with the circadian rhythm of cortisol.”
BackgroundInfluentialØksnes, M., Björnsdottir, S., Isaksson, M., Methlie, P., Carlsen, S., Nilsen, R. M., Broman, J.-E., Triebner, K., Kämpe, O., Hulting, A.-L., et al. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-4253 · Cited by 134 · cited 1×
“used during hydrocortisone infusion (28).”
Tunn, S., Möllmann, H., Barth, J., Derendorf, H., & Krieg, M. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.8.1491 · Cited by 130 · cited 1×
“At these levels the clearance of total cortisol increases (9), and the disappearance rate is negatively correlated with CBG (10).”
BackgroundAssociation of Diurnal Patterns in Salivary Cortisol With Type 2 Diabetes in the Whitehall II Study
Hackett, R. A., Steptoe, A., & Kumari, M. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-2459 · Cited by 118 · cited 1×
“A flattened diurnal cortisol slope is associated with cardiovascular mortality (23), type 2 diabetes (24), and obesity (25).”
BackgroundJones, R. L., Owen, L. J., Adaway, J. E., & Keevil, B. G. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.11.036 · Cited by 69 · cited 1×
“6–96 nmol/L of salivary cortisone, respectively (16).”
Self-citationSensitivity of bone to glucocorticoids
COOPER, M. S. (2004) · Clinical Science · doi:10.1042/cs20040070 · Cited by 67 · cited 1×
“Cortisol is inactivated through oxidation to cortisone by 11 -HSD2 in organs such as kidney, salivary glands, and the colon and cortisone is either excreted in urine or reshuttled back into the circulation, to be reduced back to cortisol by 11 -HSD1 in the tissues (17, 18).”
BackgroundCorticosteroid‐binding globulin regulates cortisol pharmacokinetics
Perogamvros, I., Aarons, L., Miller, A. G., Trainer, P. J., & Ray, D. W. (2011) · Clinical Endocrinology · doi:10.1111/j.1365-2265.2010.03897.x · Cited by 59 · cited 2×
“Salivary cortisol has been shown to reflect serum free cortisol (FF) (7).”
BackgroundThe role of 11β-hydroxysteroid dehydrogenase in the pathogenesis of hypertension
Uum, S. H. M. V., Hermus, A. R., Smits, P., Thien, T., & Lenders, J. W. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(97)00299-x · Cited by 59 · cited 1×
“Cortisol is inactivated through oxidation to cortisone by 11 -HSD2 in organs such as kidney, salivary glands, and the colon and cortisone is either excreted in urine or reshuttled back into the circulation, to be reduced back to cortisol by 11 -HSD1 in the tissues (17, 18).”
BackgroundRaff, H., & Singh, R. J. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.182717 · Cited by 57 · cited 1×
“when measuring salivary cortisol in this setting (29).”
BackgroundKrieger, D. T., & GEWIRTZ, G. P. (1974) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-39-1-46 · Cited by 52 · cited 1×
“Cortisol levels have a distinct circadian rhythm being low in the evening and at sleep onset, increasing from around 0300–0500 hours, peaking shortly after waking and then declining during the day with small peaks at meal times (1, 2).”
BackgroundBekő, G., Varga, I., Gláz, E., Sereg, M., Feldman, K., Tóth, M., Rácz, K., & Patócs, A. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.11.033 · Cited by 48 · cited 1×
“Immunoassays are complicated by cross reactivity with other steroids including cortisone, which affects specificity and test accuracy (21).”
BackgroundOwen, L. J., Adaway, J. E., Davies, S., Neale, S., El-Farhan, N., Ducroq, D., Evans, C., Rees, D. A., MacKenzie, F., & Keevil, B. G. (2013) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/0004563212473448 · Cited by 46 · cited 1×
“Liquid chromatography–tandem mass spectroscopy (LCMS/MS) analysis for serum, free, and salivary cortisol/cortisone was performed using a Waters Xevo TQ-MS mass spectrometer and a Waters Acquity LC system with an electrospray source operated in positive-ionization mode (15).”
MethodSelf-citationHSU, B. R.-S., & KUHN, R. W. (1988) · Endocrinology · doi:10.1210/endo-122-2-421 · Cited by 43 · cited 1×
“CBG has a diurnal rhythm in rats (11), and the metabolic clearance rate of cortisol in humans is significantly higher at 0500–1100 hours compared with that at 2000–0200 hours (12).”
Backgroundde LACERDA, L., KOWARSKI, A., & MIGEON, C. J. (1973) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-36-6-1043 · Cited by 41 · cited 1×
“CBG has a diurnal rhythm in rats (11), and the metabolic clearance rate of cortisol in humans is significantly higher at 0500–1100 hours compared with that at 2000–0200 hours (12).”
BackgroundBlair, J., Lancaster, G., Titman, A., Peak, M., Newlands, P., Collingwood, C., Chesters, C., Moorcroft, T., Wallin, N., Hawcutt, D., et al. (2014) · Clinical Endocrinology · doi:10.1111/cen.12302 · Cited by 38 · cited 1×
“sufficiency in patients on glucocorticoids (30).”
Assessment of glucocorticoid therapy with salivary cortisol in secondary adrenal insufficiency
Ceccato, F., Albiger, N., Reimondo, G., Frigo, A. C., Ferasin, S., Occhi, G., Mantero, F., Terzolo, M., & Scaroni, C. (2012) · European Journal of Endocrinology · doi:10.1530/eje-12-0534 · Cited by 35 · cited 1×
“The use of two salivary cortisol samples, measured 1 hour and 30 minutes after cortisone acetate, as an indication of 24-hour cortisol exposure has been suggested but this does not give an indication of fluctuating changes (27).”
MethodWhat is the best approach to tailoring hydrocortisone dose to meet patient needs in 2012?
Debono, M., & Ross, R. J. M. (2013) · Clinical Endocrinology · doi:10.1111/cen.12117 · Cited by 30 · cited 1×
“Furthermore, no consensus exists on how to titrate hydrocortisone doses in patients on glucocorticoid replacement (26).”
BackgroundSelf-citation
Cited by
Schiffer, L., Barnard, L., Baranowski, E. S., Gilligan, L. C., Taylor, A. E., Arlt, W., Shackleton, C. H. L., & Storbeck, K.-H. (2019) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2019.105439 · Cited by 450
Self-citationHusebye, E. S., Pearce, S. H., Krone, N. P., & Kämpe, O. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00136-7 · Cited by 378
Hahner, S., Ross, R. J., Arlt, W., Bancos, I., Burger-Stritt, S., Torpy, D. J., Husebye, E. S., & Quinkler, M. (2021) · Nature Reviews Disease Primers · doi:10.1038/s41572-021-00252-7 · Cited by 223
Self-citationCircadian rhythms: influence on physiology, pharmacology, and therapeutic interventions
Ayyar, V. S., & Sukumaran, S. (2021) · Journal of Pharmacokinetics and Pharmacodynamics · doi:10.1007/s10928-021-09751-2 · Cited by 205
“[91] showed that a 23% diurnal variation in plasma transcortin from baseline, as observed in healthy volunteers [90], produced modest differences in the median total AUC (B 12.”
BackgroundLC–MS/MS analysis of steroids in the clinical laboratory
Keevil, B. G. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.04.009 · Cited by 149
Self-citation
Metadata
- Authors
- Debono, M., Harrison, R. F., Whitaker, M. J., Eckland, D., Arlt, W., Keevil, B. G., & Ross, R. J.
- Affiliations
- University of Sheffield (GB)
- Diurnal (United Kingdom) (GB)
- University of Birmingham (GB)
- Department of Clinical Biochemistry (B.G.K.), University Hospital South Manchester, Manchester M23 9LT, United Kingdom
- Corresponding author
- Ross, Richard J.
- ORCID
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 2016-04-01
- Volume
- 101
- Issue
- 4
- Pages
- 1469-1477
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2269039627
- Cited by
- 128
- References
- 31
- Citations by year
- 2026: 14 · 2025: 13 · 2024: 16 · 2023: 21 · 2022: 8 · 2021: 10 · 2020: 16 · 2019: 9 · 2018: 8 · 2017: 9 · 2016: 4
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The Journal of Clinical Endocrinology & Metabolism (publishedVersion)
- PubMed (publishedVersion)
- White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Spiral (Imperial College London) (submittedVersion)
- Funders
- National Institute for Health and Care Research (CL-2013-04-001)
- European Commission (281654)
- University of Sheffield
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
- Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- salivary cortisone, salivary cortisol, serum cortisol, cortisol, diurnal cortisol rhythm, corticosteroid-binding globulin, albumin, free cortisol, sample contamination
- MeSH terms
- Adult, Chromatography, Liquid, Circadian Rhythm, Cortisone, Humans, Hydrocortisone, Male, Prospective Studies, Saliva, Salivary Glands, Cross-Over Studies, Tandem Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.