Short Loop Adrenocorticotropin (ACTH) Feedback after ACTH-(l-24) Injection in Man Is an Artifact of the Immunoradiometric Assay
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A recent report measured a decrease in plasma ACTH concentration by immunoradiometric assay (IRMA) during infusion of ACTH-(1-24) in humans. It was concluded that this decrease in ACTH concentration was due to short loop ACTH autoregulation. The present study demonstrates that the decrease in ACTH concentration measured by IRMA was due to an artifact of the IRMA. We injected 250 micrograms ACTH-(1-24), iv, into five normal male volunteers after overnight 2.5-g metyrapone administration. The ACTH concentration measured by IRMA decreased from 59.6 +/- 9.7 pmol/L before to 4.8 +/- 2.0 pmol/L 1 min after ACTH-(1-24) injection. The ACTH concentration measured by IRMA increased thereafter in a mirror image of the decline in ACTH-(1-24) measured by RIA. Addition of ACTH-(1-24) to plasma in vitro resulted in a decrease in the ACTH concentration measured by IRMA which was of similar magnitude to that observed in vivo. ACTH-(1-24) infusion in vivo or addition to ACTH-(1-39)-containing plasma in vitro decreased ACTH-(1-39) measured by IRMA by binding to N- but not C-terminal antibody without forming a detectable sandwich complex. We conclude that although ACTH short loop feedback may exist, it cannot be detected after ACTH-(1-24) injection with the use of a two-site IRMA.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This is not surprising since the high dose and low dose cosyntropin generate plasma ACTH concentrations of 22 000 to 100 000 pg/mL and 2000 pg/mL, respectively, at 2 minutes after injection [33, 34].”
From New Cutoffs for the Biochemical Diagnosis of Adrenal Insufficiency after ACTH Stimulation using Specific Cortisol Assays (2021) · cites this paper as [33]
Citations
Cites
Raff, H., & Findling, J. W. (1989) · Clinical Chemistry · doi:10.1093/clinchem/35.4.596 · Cited by 167
Self-citationA “Short” Feedback Loop in the Control of ACTH Secretion
Motta, M., MANGILI, G., & Martini, L. (1965) · Endocrinology · doi:10.1210/endo-77-2-392 · Cited by 81
Adrenocorticotropic Hormone Biotransformation, Clearance, and Catabolism*
Nicholson, W. E., Liddle, R. A., Puett, D., & Liddle, G. W. (1978) · Endocrinology · doi:10.1210/endo-103-4-1344 · Cited by 37
Evidence for Ultra-Short Loop Autoregulation of Adrenocorticotropin Secretion in Man
Boscaro, M., Sonino, N., Paoletta, A., Rampazzo, A., & Mantero, F. (1988) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-66-2-255 · Cited by 25
Control of ACTH and vasopressin in neurohypophysectomized conscious dogs
Raff, H., Merrill, D., Skelton, M. M., & Cowley, A. W. (1985) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1985.249.2.r281 · Cited by 17
Self-citationEvidence against a Self-Inhibition of ACTH Secretion in Man
Cavagnini, F., Invitti, C., Danesi, L., Passamonti, M., & Fossati, R. (2008) · Neuroendocrinology · doi:10.1159/000124229 · Cited by 5
Cited by
Bertagna, X., Guignat, L., Groussin, L., & Bertherat, J. (2009) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2009.06.001 · Cited by 222
Javorsky, B. R., Raff, H., Carroll, T. B., Algeciras-Schimnich, A., Singh, R. J., Colón-Franco, J. M., & Findling, J. W. (2021) · Journal of the Endocrine Society · doi:10.1210/jendso/bvab022 · Cited by 171
“This is not surprising since the high dose and low dose cosyntropin generate plasma ACTH concentrations of 22 000 to 100 000 pg/mL and 2000 pg/mL, respectively, at 2 minutes after injection [33, 34].”
BackgroundSelf-citationProopiomelanocortin-Derived Peptides
BERTAGNA, X. Y. (1994) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/s0889-8529(18)30079-3 · Cited by 153
Raff, H., Sharma, S. T., & Nieman, L. K. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130035 · Cited by 141
“…with ectopic ACTH, who makes biologically active fragments of POMC that are not detected in the highly spe-cific ACTH immunometric assay (74,215) Additionally, some patients with ACTH-independent (adrenal) causes of Cushing’s syndrome have mild hypercortisolism that is not suffi-cient to…”
Self-citationRubín, R. T., Phillips, J. J., McCracken, J. T., & Sadow, T. (1996) · Biological Psychiatry · doi:10.1016/0006-3223(95)00358-4 · Cited by 126
Metadata
- Authors
- RAFF, H., FINDLING, J. W., & WONG, J.
- Affiliations
- Medical College of Wisconsin (US)
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 1989-09
- Volume
- 69
- Issue
- 3
- Pages
- 678-680
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2077630230
- Cited by
- 26
- References
- 6
- Citations by year
- 2026: 1 · 2025: 1 · 2022: 1 · 2021: 2 · 2019: 1 · 2017: 1 · 2014: 4
- FWCI
- 0.55
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The Journal of Clinical Endocrinology & Metabolism (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
- Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- ACTH, short-loop feedback, ACTH1-24, metyrapone, ACTH 1-39, antibody specificity, assay interference
- MeSH terms
- Adrenocorticotropic Hormone, Adult, Feedback, Humans, Male, Radioimmunoassay, Reference Values
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Short Loop Adrenocorticotropin (ACTH) Feedback after ACTH-(l-24) Injection in Man Is an Artifact of the Immunoradiometric Assay. https://app.cochat.ai/papers/10.1210/jcem-69-3-678
- The paper
- RAFF, H., FINDLING, J. W., & WONG, J. (1989). Short Loop Adrenocorticotropin (ACTH) Feedback after ACTH-(l-24) Injection in Man Is an Artifact of the Immunoradiometric Assay. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jcem-69-3-678
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.