Comparison of Metabolic Deterioration between Insulin Analog and Regular Insulin after a 5-Hour Interruption of a Continuous Subcutaneous Insulin Infusion in Type 1 Diabetic Patients1
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
An interruption of continuous sc insulin infusion (CSII) of the insulin analog lispro should result in a more rapid metabolic deterioration of type 1 diabetic patients because of its pharmacokinetic characteristics. We analyzed the metabolic changes occurring during a 5-h interruption of CSII and the 5 h after restarting the pump in 10 type 1 diabetic patients. The study was a randomized, cross-over, open label design comparing insulin analog [Lispro (LP)] and regular insulin [Velosuline (VE)]. Plasma glucose, free insulin, glucagon,β -hydroxybutyrate (β-OHB), and nonesterified fatty acids (NEFA) were measured every hour from 0700 h (time zero) to 1700 h (600 min). After stopping CSII, the plasma glucose level was significantly higher in the LP group than in the VE group (P < 0.05–0.01). The plasma free insulin level decreased significantly with the two treatments, but was significantly lower with LP than with VE (P < 0.05–0.01). Plasma NEFA increased more rapidly and was significantly higher in the LP group than in the VE group (P < 0.01–0.05). Plasma β-OHB increased earlier with LP, but was not statistically different between the treatments. After restarting the pump, plasma glucose decreased with LP, but continued to increase with VE, and the plasma free insulin peak occurred earlier and was greater with LP than with VE (P < 0.05). Plasma NEFA and β-OHB levels decreased significantly with the two treatments, but more dramatically with LP treatment. Thus, a short interruption of Lispro in CSII is associated with an earlier, greater metabolic deterioration, but Lispro corrected this metabolic deterioration more effectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bode, B. W., Steed, R. D., & Davidson, P. C. (1996) · Diabetes Care · doi:10.2337/diacare.19.4.324 · Cited by 257
Automated kinetic method for D-3-hydroxybutyrate in plasma or serum
McMurray, C. H., Blanchflower, W. J., & Rice, D. A. (1984) · Clinical Chemistry · doi:10.1093/clinchem/30.3.421 · Cited by 188
Cited by
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Insulin analogues and their potential in the management of diabetes mellitus
Bolli, G. B., Di Marchi, R. D., Park, G. D., Pramming, S., & Koivisto, V. A. (1999) · Diabetologia · doi:10.1007/s001250051286 · Cited by 349
Insulin Pump Therapy With Automated Insulin Suspension in Response to Hypoglycemia
Choudhary, P., Shin, J., Wang, Y., Evans, M. L., Hammond, P. J., Kerr, D., Shaw, J. A. M., Pickup, J. C., & Amiel, S. A. (2011) · Diabetes Care · doi:10.2337/dc10-2411 · Cited by 175
“The risk of ketosis and hyperglycemia after the 2-h suspension of insulin delivery is low (8,9).”
BackgroundRaskin, P., Holcombe, J. H., Tamborlane, W. V., Malone, J. I., Strowig, S., Ahern, J. A., & Lavent, F. (2001) · Journal of Diabetes and its Complications · doi:10.1016/s1056-8727(01)00168-4 · Cited by 71
Hoogma, R., & Schumicki, D. (2006) · Hormone and Metabolic Research · doi:10.1055/s-2006-944549 · Cited by 66
Metadata
- Authors
- Guerci, B., Meyer, L., Sallé, A., Charrié, A., Dousset, B., Ziegler, O., & Drouin, P.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 1999-08-01
- Volume
- 84
- Issue
- 8
- Pages
- 2673-2678
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W1967273487
- Cited by
- 58
- References
- 2
- FWCI
- 1.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Metabolic Deterioration between Insulin Analog and Regular Insulin after a 5-Hour Interruption of a Continuous Subcutaneous Insulin Infusion in Type 1 Diabetic Patients1. https://app.cochat.ai/papers/10.1210/jcem.84.8.5912
- The paper
- Guerci, B., Meyer, L., Sallé, A., Charrié, A., Dousset, B., Ziegler, O., & Drouin, P. (1999). Comparison of Metabolic Deterioration between Insulin Analog and Regular Insulin after a 5-Hour Interruption of a Continuous Subcutaneous Insulin Infusion in Type 1 Diabetic Patients1. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jcem.84.8.5912
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.