CoChat

Insulin Pump Therapy With Automated Insulin Suspension in Response to Hypoglycemia

Open access

The DOI matches its Crossref record, with a small difference in title or year; 12 of the 14 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To evaluate a sensor-augmented insulin pump with a low glucose suspend (LGS) feature that automatically suspends basal insulin delivery for up to 2 h in response to sensor-detected hypoglycemia. RESEARCH DESIGN AND METHODS: The LGS feature of the Paradigm Veo insulin pump (Medtronic, Inc., Northridge, CA) was tested for 3 weeks in 31 adults with type 1 diabetes. RESULTS: There were 166 episodes of LGS: 66% of daytime LGS episodes were terminated within 10 min, and 20 episodes lasted the maximum 2 h. LGS use was associated with reduced nocturnal duration ≤2.2 mmol/L in those in the highest quartile of nocturnal hypoglycemia at baseline (median 46.2 vs. 1.8 min/day, P = 0.02 [LGS-OFF vs. LGS-ON]). Median sensor glucose was 3.9 mmol/L after 2-h LGS and 8.2 mmol/L at 2 h after basal restart. CONCLUSIONS: Use of an insulin pump with LGS was associated with reduced nocturnal hypoglycemia in those at greatest risk and was well accepted by patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc10-2411

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Duration of nocturnal hypoglycemia (sensor glucose < 2.2 mmol/L) with and without LGS. The bars show median duration of hypoglycemia at night with LGS-OFF (black bars) and LGS-ON (gray bars) by quartile (q) of nocturnal hypoglycemia exposure at baseline.
Figure 1 Duration of nocturnal hypoglycemia (sensor glucose < 2.2 mmol/L) with and without LGS. The bars show median duration of hypoglycemia at night with LGS-OFF (black bars) and LGS-ON (gray bars) by quartile (q) of nocturnal hypoglycemia exposure at baseline.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 180

Metadata

Authors
Choudhary, P., Shin, J., Wang, Y., Evans, M. L., Hammond, P. J., Kerr, D., Shaw, J. A. M., Pickup, J. C., & Amiel, S. A.
Affiliations
  • King's College London (GB)
  • Medtronic (United States) (US)
  • University of Cambridge (GB)
  • Harrogate District Hospital (GB)
  • Bournemouth Diabetes and Endocrine Centre, Bournemouth District General Hospital, Bournemouth, U.K.
  • Newcastle University (GB)
Corresponding author
Choudhary, Pratik
Venue
Diabetes Care
Published
2011-08-19
Volume
34
Issue
9
Pages
2023-2025
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2071497593
Cited by
175
References
14
Citations by year
2025: 3 · 2024: 4 · 2022: 2 · 2021: 3 · 2020: 7 · 2019: 5 · 2018: 14 · 2017: 12 · 2016: 16 · 2015: 17 · 2014: 24 · 2013: 30 · 2012: 33
FWCI
23.88
Type
journal article
Language
en
Open access
Licence
cc-by-nc-nd
Locations
  • Diabetes Care (publishedVersion, cc-by-nc-nd)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Research Portal (King's College London) (submittedVersion)
  • Newcastle University ePrints (Newcastle Univesity)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
insulin pump therapy, low glucose suspend, sensor-augmented pump, type 1 diabetes, nocturnal hypoglycemia, continuous glucose monitoring, hypoglycemia detection
MeSH terms
Adult, Circadian Rhythm, Female, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Male, Middle Aged

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Insulin Pump Therapy With Automated Insulin Suspension in Response to Hypoglycemia. https://app.cochat.ai/papers/10.2337/dc10-2411
The paper
Choudhary, P., Shin, J., Wang, Y., Evans, M. L., Hammond, P. J., Kerr, D., Shaw, J. A. M., Pickup, J. C., & Amiel, S. A. (2011). Insulin Pump Therapy With Automated Insulin Suspension in Response to Hypoglycemia. Diabetes Care. https://doi.org/10.2337/dc10-2411

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.