The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Growth factor release from tissue engineering scaffolds
Abstract
Synthetic scaffold materials are used in tissue engineering for a variety of applications, including physical supports for the creation of functional tissues, protective gels to aid in wound healing and to encapsulate cells for localized hormone-delivery therapies. In order to encourage successful tissue growth, these scaffold materials must incorporate vital growth factors that are released to control their development. A major challenge lies in the requirement for these growth factor delivery mechanisms to mimic the in-vivo release profiles of factors produced during natural tissue morphogenesis or repair. This review highlights some of the major strategies for creating scaffold constructs reported thus far, along with the approaches taken to incorporate growth factors within the materials and the benefits of combining tissue engineering and drug delivery expertise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polymeric systems for controlled drug release
Uhrich, K. E., Cannizzaro, S. M., Langer, R. S., & Shakesheff, K. M. (1999) · Chemical Reviews · doi:10.1021/cr940351u · Cited by 2,633
Self-citationLi, S. M., Garreau, H., & Vert, M. (1990) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00700871 · Cited by 733
Host response to tissue engineered devices
Babensee, J. E., Anderson, J. M., McIntire, L. V., & Mikos, A. G. (1998) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00023-4 · Cited by 585
Cited by
Lutolf, M. P., Lauer-Fields, J. L., Schmoekel, H. G., Metters, A. T., Weber, F. E., Fields, G. B., & Hubbell, J. A. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0737381100 · Cited by 1,508
Functionalized synthetic biodegradable polymer scaffolds for tissue engineering.
Liu, X., Holzwarth, J. M., & Ma, P. X. (2012) · Macromolecular Bioscience · doi:10.1002/mabi.201100466 · Cited by 290
Medicinal plants and their components for wound healing applications
Sharma, A., Khanna, S., Kaur, G., & Singh, I. (2021) · Future Journal of Pharmaceutical Sciences · doi:10.1186/s43094-021-00202-w · Cited by 245
Processing of Materials for Regenerative Medicine Using Supercritical Fluid Technology
García-González, C. A., Concheiro, A., & Alvarez-Lorenzo, C. (2015) · Bioconjugate Chemistry · doi:10.1021/bc5005922 · Cited by 112
Sreejalekshmi, K. G., & Nair, P. D. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32980 · Cited by 81
Metadata
- Authors
- Whitaker, M. J., Quirk, R. A., Howdle, S. M., & Shakesheff, K. M.
- Venue
- Journal of Pharmacy and Pharmacology
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-11-01
- Volume
- 53
- Issue
- 11
- Pages
- 1427-1437
- ISSN
- 0022-3573 (ISSN-L)
- 2042-7158
- OpenAlex
- W2083774544
- Cited by
- 282
- References
- 3
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Growth factor release from tissue engineering scaffolds. https://app.cochat.ai/papers/10.1211/0022357011777963
- The paper
- Whitaker, M. J., Quirk, R. A., Howdle, S. M., & Shakesheff, K. M. (2001). Growth factor release from tissue engineering scaffolds. Journal of Pharmacy and Pharmacology. https://doi.org/10.1211/0022357011777963
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.