CoChat

Impaired visual evoked flow velocity response in cerebral amyloid angiopathy

Open access
Smith, E. E., Vijayappa, M., Lima, F., Delgado, P., Wendell, L., Rosand, J., Greenberg, S. M. · 2008 · Neurology
Cited by 98

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Animal models of cerebral amyloid angiopathy (CAA) exhibit abnormal vascular reactivity. We determined whether vascular reactivity, measured by transcranial Doppler ultrasound (TCD), is reduced in humans with CAA. METHODS: Cases were recruited from an established prospective study of CAA. Healthy controls were recruited from a study of normal aging. Evoked mean flow velocity increase in the posterior cerebral artery (PCA) was measured while subjects viewed a flashing alternating checkerboard stimulus. In a separate but partially overlapping cohort we measured the mean flow velocity increase in the middle cerebral artery (MCA) while subjects inhaled carbon dioxide. RESULTS: The visual evoked mean flow velocity increase was 8.0 +/- 6.1% in CAA (n = 11) compared to 17.4 +/- 5.7% in controls (n = 9, p = 0.002). The PCA pulsatility index, a marker of distal vascular resistance, was higher in CAA (CAA 1.35 +/- 0.35, control 1.04 +/- 0.14, p = 0.03). Among CAA subjects, lower visual evoked mean flow velocity increase was associated with a higher number of hemorrhages seen on MRI (r = -0.87, p = 0.0005) and higher MRI white matter hyperintensity volume (r = -0.67, p = 0.02). The MCA response to carbon dioxide did not differ between CAA and control in 20 subjects (9 CAA, 11 control, p = 0.54). CONCLUSIONS: Cerebral amyloid angiopathy (CAA) was associated with decreased vascular reactivity in response to visual stimulation, possibly reflecting the occipital predilection of the disease. The association of posterior cerebral artery (PCA) evoked flow velocity response with elevated PCA pulsatility index and MRI markers of small vessel disease suggests that abnormal PCA evoked flow velocity in CAA is caused by pathology of the distal resistance vessels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/01.wnl.0000327887.64299.a4

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 98

Metadata

Authors
Smith, E. E., Vijayappa, M., Lima, F., Delgado, P., Wendell, L., Rosand, J., & Greenberg, S. M.
Venue
Neurology
Published
2008-10-28
Volume
71
Issue
18
Pages
1424-1430
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W2116896297
Cited by
98
References
11
FWCI
2.75
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impaired visual evoked flow velocity response in cerebral amyloid angiopathy. https://app.cochat.ai/papers/10.1212/01.wnl.0000327887.64299.a4
The paper
Smith, E. E., Vijayappa, M., Lima, F., Delgado, P., Wendell, L., Rosand, J., & Greenberg, S. M. (2008). Impaired visual evoked flow velocity response in cerebral amyloid angiopathy. Neurology. https://doi.org/10.1212/01.wnl.0000327887.64299.a4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.