CoChat

Optic Nerve Topography in Multiple Sclerosis Diagnosis: The Utility of Visual Evoked Potentials

Open access
Vidal-Jordana, Angela, Rovira, Alex, Arrambide, Georgina, Otero-Romero, Susana, Río, Jordi, Comabella, Manuel, Nos, Carlos, Castilló, Joaquin, Galan, Ingrid, Cabello, Sergio, Moncho, Dulce, Rahnama, Kimia, Thonon, Vanessa, Rodríguez-Acevedo, Breogan, Zabalza, Ana, Midaglia, Luciana, Auger, Cristina, Sastre-Garriga, Jaume, Montalban, Xavier, Tintoré, Mar · 2021 · Neurology
Cited by 63

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To assess the added value of the optic nerve region (by using visual evoked potentials [VEPs]) to the current diagnostic criteria. METHODS: From the Barcelona clinically isolated syndrome (CIS) cohort, patients with complete information to assess dissemination in space (DIS), the optic nerve region, and dissemination in time at baseline (n = 388) were selected. Modified DIS (modDIS) criteria were constructed by adding the optic nerve to the current DIS regions. The DIS and modDIS criteria were evaluated with univariable Cox proportional hazard regression analyses with the time to the second attack as the outcome. A subset of these patients who had at least 10 years of follow-up or a second attack occurring within 10 years (n = 151) were selected to assess the diagnostic performance. The analyses were also performed according to CIS topography (optic neuritis vs non-optic neuritis). RESULTS: The addition of the optic nerve as a fifth region improved the diagnostic performance by slightly increasing the accuracy (2017 DIS 75.5%, modDIS 78.1%) and the sensitivity (2017 DIS 79.2%, modDIS 82.3%) without lowering the specificity (2017 DIS 52.4%, modDIS 52.4%). When the analysis was conducted according to CIS topography, the modDIS criteria performed similarly in both optic neuritis and non-optic neuritis CIS. CONCLUSION: The addition of the optic nerve, assessed by VEP, as a fifth region in the current DIS criteria slightly improves the diagnostic performance because it increases sensitivity without losing specificity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/wnl.0000000000011339

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 63

Metadata

Authors
Vidal-Jordana, A., Rovira, A., Arrambide, G., Otero-Romero, S., Río, J., Comabella, M., Nos, C., Castilló, J., Galan, I., Cabello, S., Moncho, D., Rahnama, K., Thonon, V., Rodríguez-Acevedo, B., Zabalza, A., Midaglia, L., Auger, C., Sastre-Garriga, J., Montalban, X., & Tintoré, M.
Venue
Neurology
Published
2021-01-26
Volume
96
Issue
4
Pages
e482-e490
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W3110670790
Cited by
63
References
9
FWCI
5.73
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optic Nerve Topography in Multiple Sclerosis Diagnosis: The Utility of Visual Evoked Potentials. https://app.cochat.ai/papers/10.1212/wnl.0000000000011339
The paper
Vidal-Jordana, A., Rovira, A., Arrambide, G., Otero-Romero, S., Río, J., Comabella, M., Nos, C., Castilló, J., Galan, I., Cabello, S., Moncho, D., Rahnama, K., Thonon, V., Rodríguez-Acevedo, B., Zabalza, A., Midaglia, L., Auger, C., Sastre-Garriga, J., Montalban, X., & Tintoré, M. (2021). Optic Nerve Topography in Multiple Sclerosis Diagnosis: The Utility of Visual Evoked Potentials. Neurology. https://doi.org/10.1212/wnl.0000000000011339

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.