Cited by 254Atrial Fibrillation Management and OutcomesCardiovascular and Diving-Related ComplicationsAcute Ischemic Stroke Management

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke

Open access

Abstract

OBJECTIVES: The usefulness of the implantable loop recorder (ILR) with improved atrial fibrillation (AF) detection capability (Reveal XT) and the factors associated with AF in the setting of unexplained stroke were investigated. METHODS: A cohort study is reported of 51 patients in whom ILRs were implanted for the investigation of ischemic stroke for which no cause had been found (cryptogenic) following appropriate vascular and cardiac imaging and at least 24 hours of cardiac rhythm monitoring. RESULTS: The patients were aged from 17 to 73 (median 52) years. Of the 30 patients with a shunt investigation, 22 had a patent foramen ovale (73.3%; 95% confidence interval [CI] 56.5%-90.1%). AF was identified in 13 (25.5%; 95% CI 13.1%-37.9%) cases. AF was associated with increasing age (p = 0.018), interatrial conduction block (p = 0.02), left atrial volume (p = 0.025), and the occurrence of atrial premature contractions on preceding external monitoring (p = 0.004). The median (range) of monitoring prior to AF detection was 48 (0-154) days. CONCLUSION: In patients with unexplained stroke, AF was detected by ILR in 25.5%. Predictors of AF were identified, which may help to target investigations. ILRs may have a central role in the future in the investigation of patients with unexplained stroke.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/wnl.0b013e31828f1828

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

Sorted by citations

Items 101–200 of 254

Metadata

Authors
Cotter, P. E., Martin, P. J., Ring, L., Warburton, E. A., Belham, M., & Pugh, P. J.
Affiliations
Cambridge University Hospitals NHS Foundation Trust (GB)
Venue
Neurology
Published
2013-04-23
Volume
80
Issue
17
Pages
1546-1550
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W2021263194
Cited by
254
References
19
Citations by year
2026: 4 · 2025: 7 · 2024: 10 · 2023: 11 · 2022: 18 · 2021: 25 · 2020: 11 · 2019: 21 · 2018: 18 · 2017: 21 · 2016: 26 · 2015: 29 · 2014: 44 · 2013: 9
FWCI
24.45
Type
journal article
Language
en
Open access
Locations
  • Neurology (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Cardiovascular and Diving-Related Complications
  • Health Sciences › Medicine › Clinical Neurology › Acute Ischemic Stroke Management
Keywords
atrial fibrillation, implantable loop recorder, cryptogenic stroke, patent foramen ovale, left atrial volume, premature atrial contractions, atrial fibrillation risk factors, cardiac rhythm monitoring
MeSH terms
Adolescent, Adult, Aged, Atrial Fibrillation, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Cohort Studies, Incidence, Stroke, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review