The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke
Open accessAbstract
OBJECTIVES: The usefulness of the implantable loop recorder (ILR) with improved atrial fibrillation (AF) detection capability (Reveal XT) and the factors associated with AF in the setting of unexplained stroke were investigated. METHODS: A cohort study is reported of 51 patients in whom ILRs were implanted for the investigation of ischemic stroke for which no cause had been found (cryptogenic) following appropriate vascular and cardiac imaging and at least 24 hours of cardiac rhythm monitoring. RESULTS: The patients were aged from 17 to 73 (median 52) years. Of the 30 patients with a shunt investigation, 22 had a patent foramen ovale (73.3%; 95% confidence interval [CI] 56.5%-90.1%). AF was identified in 13 (25.5%; 95% CI 13.1%-37.9%) cases. AF was associated with increasing age (p = 0.018), interatrial conduction block (p = 0.02), left atrial volume (p = 0.025), and the occurrence of atrial premature contractions on preceding external monitoring (p = 0.004). The median (range) of monitoring prior to AF detection was 48 (0-154) days. CONCLUSION: In patients with unexplained stroke, AF was detected by ILR in 25.5%. Predictors of AF were identified, which may help to target investigations. ILRs may have a central role in the future in the investigation of patients with unexplained stroke.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Much longer monitoring using ILRs can further improve the diagnostic yield for syncope, as high as 85% in some studies (Cotter et al., 2013).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Cotter et al., 2013
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adams, H. P., Bendixen, B. H., Kappelle, L. J., Biller, J., Love, B. B., Gordon, D., & Marsh, E. E. (1993) · Stroke · doi:10.1161/01.str.24.1.35 · Cited by 12,350
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Marini, C., De Santis, F., Sacco, S., Russo, T., Olivieri, L., Totaro, R., & Carolei, A. (2005) · Stroke · doi:10.1161/01.str.0000166053.83476.4a · Cited by 949
Hindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422
Jabaudon, D., Sztajzel, J. M., Sievert, K., Landis, T., & Sztajzel, R. F. (2004) · Stroke · doi:10.1161/01.str.0000131269.69502.d9 · Cited by 414
Capucci, A., Santini, M., Padeletti, L., Gulizia, M. M., Botto, G., Boriani, G., Ricci, R. P., Favale, S., Zolezzi, F., Belardino, N. D., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.044 · Cited by 400
BOTTO, G. L., PADELETTI, L., SANTINI, M., CAPUCCI, A., GULIZIA, M., ZOLEZZI, F., FAVALE, S., MOLON, G., RICCI, R., BIFFI, M., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01320.x · Cited by 380
New Approach to Stroke Subtyping: The A-S-C-O (Phenotypic) Classification of Stroke
Amarenco, P., Bogousslavsky, J., Caplan, L. R., Donnan, G. A., & Hennerici, M. G. (2009) · Cerebrovascular Diseases · doi:10.1159/000210433 · Cited by 333
Liao, J., Khalid, Z., Scallan, C., Morillo, C., & O’Donnell, M. (2007) · Stroke · doi:10.1161/strokeaha.106.478685 · Cited by 331
Atrial fibrillation detected by mobile cardiac outpatient telemetry in cryptogenic TIA or stroke
Tayal, A. H., Tian, M., Kelly, K., Jones, S. C., Wright, D. G., Singh, D., Jarouse, J., Brillman, J. S., Murali, S., & Gupta, R. (2008) · Neurology · doi:10.1212/01.wnl.0000325059.86313.31 · Cited by 316
Cited by
Sorted by citations
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
The Clinical Profile and Pathophysiology of Atrial Fibrillation
Andrade, J. G., Khairy, P., Dobrev, D., & Nattel, S. (2014) · Circulation Research · doi:10.1161/circresaha.114.303211 · Cited by 1,232
Sposato, L. A., Cipriano, L. E., Saposnik, G., Vargas, E. R., Riccio, P. M., & Hachinski, V. (2015) · The Lancet Neurology · doi:10.1016/s1474-4422(15)70027-x · Cited by 694
Andrade, J. G., Aguilar, M., Atzema, C. L., Bell, A., Cairns, J. A., Cheung, C. C., Cox, J. L., Dorian, P., Gladstone, D. J., Healey, J. S., et al. (2020) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2020.09.001 · Cited by 593
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.038 · Cited by 303
Malmo, V., Nes, B. M., Amundsen, B. H., Tjonna, A.-E., Stoylen, A., Rossvoll, O., Wisloff, U., & Loennechen, J. P. (2016) · Circulation · doi:10.1161/circulationaha.115.018220 · Cited by 263
Görenek, B., Bax, J. J., Boriani, G., Chen, S., Dagres, N., Glotzer, T. V., Healey, J. S., Israel, C. W., Kudaiberdieva, G., Levin, L., et al. (2017) · EP Europace · doi:10.1093/europace/eux163 · Cited by 249
Posterior circulation ischaemic stroke
Merwick, Á., & Werring, D. J. (2014) · BMJ · doi:10.1136/bmj.g3175 · Cited by 241
Grond, M., Jauss, M., Hamann, G., Stark, E., Veltkamp, R., Nabavi, D., Horn, M., Weimar, C., Köhrmann, M., Wachter, R., et al. (2013) · Stroke · doi:10.1161/strokeaha.113.001884 · Cited by 229
Silent atrial fibrillation: epidemiology, diagnosis, and clinical impact
Dilaveris, P., & Kennedy, H. (2017) · Clinical Cardiology · doi:10.1002/clc.22667 · Cited by 175
Medical Services Advisory Committee
Culyer, A. J. (2014) · Cited by 198
Uncovering Atrial Fibrillation Beyond Short-Term Monitoring in Cryptogenic Stroke Patients
Brachmann, J., Morillo, C. A., Sanna, T., Lazzaro, V. D., Diener, H., Bernstein, R. A., Rymer, M., Ziegler, P., Liu, S., & PASSMAN, R. S. (2016) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003333 · Cited by 183
Atrial Cardiopathy: A Broadened Concept of Left Atrial Thromboembolism Beyond Atrial Fibrillation
Kamel, H., Okin, P. M., Longstreth, W. T., Elkind, M. S. V., & Soliman, E. Z. (2015) · Future Cardiology · doi:10.2217/fca.15.22 · Cited by 175
Pristipino, C., Sievert, H., D’Ascenzo, F., Mas, J., Meier, B., Scacciatella, P., Hildick‐Smith, D., Gaïta, F., Toni, D., Kyrle, P. A., et al. (2019) · EuroIntervention · doi:10.4244/eij-d-18-00622 · Cited by 157
Predictors of Finding Occult Atrial Fibrillation After Cryptogenic Stroke
Favilla, C. G., Ingala, E., Jara, J., Fessler, E. B., Cucchiara, B. L., Messe, S. R., Mullen, M. T., Prasad, A., Siegler, J. E., Hutchinson, M. D., et al. (2015) · Stroke · doi:10.1161/strokeaha.114.007763 · Cited by 136
Rubiera, M., Aires, A., Antonenko, K., Lémeret, S., Nolte, C. H., Jukka Putaala, A., Schnabel, R. B., Tuladhar, A. M., Werring, D. J., Zeraatkar, D., et al. (2022) · European Stroke Journal · doi:10.1177/23969873221099478 · Cited by 136
Management of atrial high-rate episodes detected by cardiac implanted electronic devices
Freedman, B., Boriani, G., Glotzer, T. V., Healey, J. S., Kirchhof, P. F., & Potpara, T. (2017) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2017.94 · Cited by 120
Christensen, L. M., Krieger, D. W., Højberg, S., Pedersen, O. D., Karlsen, F. M., Jacobsen, M. D., Worck, R. H., Nielsen, H., Ægidius, K. L., Jeppesen, L. L., et al. (2014) · European Journal of Neurology · doi:10.1111/ene.12400 · Cited by 118
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P. F., Balsam, P., Baranchuk, A. M., Cantillon, D. J., Dilaveris, P., Dubner, S., El‐Sherif, N., et al. (2017) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12447 · Cited by 123
Poli, S., Diedler, J., Härtig, F., Götz, N., Bauer, A., Sachse, T., Müller, K., Müller, I. I., Stimpfle, F., Duckheim, M., et al. (2015) · European Journal of Neurology · doi:10.1111/ene.12843 · Cited by 104
Tse, G., Wong, C. W., Gong, M., Wong, W. T., Bazoukis, G., Wong, S. H., Li, G., Wu, W. K. K., Tse, L. A., Lampropoulos, K. M., et al. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.09.176 · Cited by 102
Ziegler, P., Rogers, J., Ferreira, S. W., Nichols, A. J., Richards, M., Koehler, J. L., & Sarkar, S. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.06.039 · Cited by 98
Choe, W. C., PASSMAN, R. S., Brachmann, J., Morillo, C. A., Sanna, T., Bernstein, R. A., Lazzaro, V. D., Diener, H., Rymer, M. M., Beckers, F., et al. (2015) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2015.06.012 · Cited by 98
Israel, C. W., Kitsiou, A., Kalyani, M., Deelawar, S., Ekosso‐Ejangue, L., Rogalewski, A., Hagemeister, C., Minnerup, J., & Schäbitz, W. (2017) · Thrombosis and Haemostasis · doi:10.1160/th17-02-0072 · Cited by 96
Evaluation of Cryptogenic Stroke With Advanced Diagnostic Techniques
Bang, O. Y., Ovbiagele, B. I., & Kim, J. S. (2014) · Stroke · doi:10.1161/strokeaha.113.003720 · Cited by 93
Wagoner, D. R. V., Piccini, J. P., Albert, C. M., Anderson, M. E., Benjamin, E. J., Brundel, B. J. J. M., Califf, R. M., Calkins, H. G., Chen, P., Chiamvimonvat, N., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.11.011 · Cited by 95
Dussault, C., Toeg, H. D., Nathan, M., Wang, Z. J., Roux, J.-F., & Secemsky, E. A. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.002521 · Cited by 87
Kochhäuser, S., Dechering, D. G., Dittrich, R., Reinke, F., Ritter, M., Ramtin, S., Duning, T., Frommeyer, G., & Eckardt, L. (2014) · Stroke · doi:10.1161/strokeaha.113.003788 · Cited by 86
Left Atria Strain Is a Surrogate Marker for Detection of Atrial Fibrillation in Cryptogenic Strokes
Pagola, J., González‐Alujas, T., Flores, A., Muchada, M., Rodríguez‐Luna, D., Seró, L., Rubiera, M., Boned, S., Ribó, M., Álvarez‐Sabín, J., et al. (2014) · Stroke · doi:10.1161/strokeaha.114.005540 · Cited by 84
Tsivgoulis, G. K., Katsanos, A. H., Köhrmann, M., Caso, V., Perren, F., Palaiodimou, L., Deftereos, S. G., Giannopoulos, S., Ellul, J., Krogias, C., et al. (2019) · Journal of Stroke · doi:10.5853/jos.2019.01067 · Cited by 82
Current and Future Use of Insertable Cardiac Monitors
Giancaterino, S., Lupercio, F. A., Nishimura, M., & Hsu, J. C. (2018) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.06.001 · Cited by 81
Diamantopoulos, A., Sawyer, L., Lip, G. Y. H., Witte, K. K., Reynolds, M. R., Fauchier, L., Thijs, V., Brown, B., Angulo, M. E. Q., & Diener, H. (2016) · International Journal of Stroke · doi:10.1177/1747493015620803 · Cited by 78
Acute Silent Brain Infarction in Monocular Visual Loss of Ischemic Origin
Lauda, F., Neugebauer, H., Reiber, L., & Jüttler, E. (2015) · Cerebrovascular Diseases · doi:10.1159/000437274 · Cited by 76
Bertaglia, E., Blank, B., Blomström‐Lundqvist, C., Brandes, A., Cabanelas, N., Dan, G. A., Dichtl, W., Goette, A., de Groot, J. R., Lubiński, A., et al. (2019) · EP Europace · doi:10.1093/europace/euz172 · Cited by 72
The Reveal LINQ insertable cardiac monitor
Tomson, T. T., & Passman, R. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.953059 · Cited by 72
Patent Foramen Ovale Closure: State of the Art
Giblett, J. P., Williams, L. K., Kyranis, S. J., Shapiro, L. M., & Calvert, P. A. (2020) · Interventional Cardiology Reviews Research Resources · doi:10.15420/icr.2019.27 · Cited by 65
Cryptogenic stroke: Is silent atrial fibrillation the culprit?
Glotzer, T. V., & Ziegler, P. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.09.058 · Cited by 63
AF burden is important - fact or fiction?
Boriani, G., Diemberger, I., Ziacchi, M., Valzania, C., Gardini, B., Cimaglia, P., Martignani, C., & Biffi, M. (2014) · International Journal of Clinical Practice · doi:10.1111/ijcp.12326 · Cited by 59
Locati, E. H., Vecchi, A. M., Vargiu, S., Cattafi, G., & Lunati, M. (2013) · EP Europace · doi:10.1093/europace/eut337 · Cited by 54
Newer technologies for detection of atrial fibrillation
Zungsontiporn, N., & Link, M. S. (2018) · BMJ · doi:10.1136/bmj.k3946 · Cited by 53
Albers, G. W., Bernstein, R. A., Brachmann, J., Camm, A. J., Easton, J. D., Fromm, P., Goto, S., Granger, C. B., Hohnloser, S. H., Hylek, E. M., et al. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.115.002944 · Cited by 54
Ziegler, P., Rogers, J., Ferreira, S. W., Nichols, A. J., Sarkar, S., Koehler, J. L., Warman, E. N., & Richards, M. (2015) · Cerebrovascular Diseases · doi:10.1159/000439063 · Cited by 48
Patent Foramen Ovale Closure in 2019
Giblett, J. P., Abdul‐Samad, O., Shapiro, L. M., Rana, B. S., & Calvert, P. A. (2019) · Interventional Cardiology Reviews Research Resources · doi:10.15420/icr.2018.33.2 · Cited by 48
Detection of Atrial Fibrillation in Cryptogenic Stroke
Hæusler, K. G., Tütüncü, S., & Schnabel, R. B. (2018) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-018-0871-1 · Cited by 49
Afzal, M. R., Gunda, S., Waheed, S., Sehar, N., Maybrook, R. J., Dawn, B., & Lakkireddy, D. (2015) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12688 · Cited by 44
Baturova, M. A., Sheldon, S. H., Carlson, J., Brady, P. A., Lin, G., Rabinstein, A. A., Friedman, P. A., & Platonov, P. G. (2016) · BMC Cardiovascular Disorders · doi:10.1186/s12872-016-0384-2 · Cited by 47
Carrazco, C., Golyan, D., Kahen, M., Black, K. S., Libman, R., & Katz, J. M. (2017) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2017.08.022 · Cited by 44
Optimal Duration of Monitoring for Atrial Fibrillation in Cryptogenic Stroke: A Nonsystematic Review
Hariri, E. H., Hachem, A. A., Sarkis, G., & Nasr, S. (2016) · BioMed Research International · doi:10.1155/2016/5704963 · Cited by 47
Bayés syndrome and acute cardioembolic ischemic stroke
Arboix, A., Martí, L., Dorison, S., & Sánchez, M. J. (2017) · World Journal of Clinical Cases · doi:10.12998/wjcc.v5.i3.93 · Cited by 41
New Directions in Cardiac Arrhythmia Management: Present Challenges and Future Solutions
Nattel, S., Andrade, J. G., Macle, L., Rivard, L., Dyrda, K., Mondesert, B. A., & Khairy, P. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2014.09.027 · Cited by 37
Angelis, M. V. D., Stefano, V. D., Franciotti, R., Furia, N., Girolamo, E. D., ONOFRJ, M. C., & Faustino, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-60180-6 · Cited by 37
Atrial Cardiomyopathy in Valvular Heart Disease: From Molecular Biology to Clinical Perspectives
Molnár, A. Á., Sánta, A., Pásztor, D. T., & Merkely, B. P. (2023) · Cells · doi:10.3390/cells12131796 · Cited by 36
Sharma, S. P., Sangha, R. S., Dahal, K. B., & Krishnamoorthy, P. M. (2016) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-016-0198-2 · Cited by 36
Dilaveris, P., Antoniou, C. K., Caiani, E. G., Casado-Arroyo, R., Climent, A. M., Cluitmans, M. J. M., Cowie, M., Doehner, W., Guerra, F., Jensen, M. T., et al. (2022) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztac026 · Cited by 40
Short-term associations between ambient air pollution and acute atrial fibrillation episodes
Dahlquist, M., Frykman, V., Kemp-Gudmundsdottir, K., Svennberg, E., Wellenius, G. A., & Ljungman, P. L. S. (2020) · Environment International · doi:10.1016/j.envint.2020.105765 · Cited by 35
Skrebelyte-Strøm, L., Rønning, O. M., Dahl, F. A., Steine, K., & Kjekshus, H. (2022) · EP Europace · doi:10.1093/europace/euac092 · Cited by 35
Embolic strokes of undetermined source: theoretical construct or useful clinical tool?
Tsivgoulis, G. K., Katsanos, A. H., Köhrmann, M., Caso, V., Lemmens, R., Tsioufis, K. P., Paraskevas, G. P., Bornstein, N. M., Schellinger, P. D., Alexandrov, A. V., et al. (2019) · Therapeutic Advances in Neurological Disorders · doi:10.1177/1756286419851381 · Cited by 34
Cuadrado‐Godia, E., Benito, B., Ois, Á., Vallès, E., Rodríguez-Campello, A., Steinhauer, E. G., Cabrera, S., Alcalde, Ó., Jiménez-López, J. I., Jiménez-Conde, J., et al. (2019) · European Journal of Neurology · doi:10.1111/ene.14061 · Cited by 34
Andrade, J. G., Field, T. S., & Khairy, P. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00100 · Cited by 36
Cryptogenic ischemic stroke and prevalence of asymptomatic atrial fibrillation
Jorfida, M., Antolini, M., Cerrato, E., Caprioli, M., Castagno, D., Garrone, P., Budano, C., Cerrato, P., & Gaïta, F. (2014) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000181 · Cited by 36
Total atrial conduction time to predict occult atrial fibrillation after cryptogenic stroke
Müller, P., Ivanov, V., Kara, K., Klein‐Wiele, O., Forkmann, M., Piorkowski, C., Blockhaus, C., Dimitroulis, D., Afzal, S., Shin, D., et al. (2016) · Clinical Research in Cardiology · doi:10.1007/s00392-016-1029-2 · Cited by 32
Pamporis, K., Karakasis, P., Sagris, Μ., Theofilis, P., Milaras, N., Pantelidaki, A., Mourouzis, I. S., Fragakis, N., Vlachos, K. G., Kordalis, A., et al. (2025) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwaf138 · Cited by 31
Prolonged Cardiac Monitoring for Detection of Paroxysmal Atrial Fibrillation After Cerebral Ischemia
Rabinstein, A. A. (2014) · Stroke · doi:10.1161/strokeaha.113.003389 · Cited by 31
Todo, K., Iwata, T., Doijiri, R., Yamagami, H., Morimoto, M., Hashimoto, T., Sonoda, K., Yamazaki, H., Junpei, K., Okazaki, S., et al. (2020) · Cerebrovascular Diseases · doi:10.1159/000505958 · Cited by 31
Ischemic stroke in young adults
Stack, C. A., & Cole, J. W. (2018) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000000564 · Cited by 30
Depuydt, S., Sarov, M., Vandendries, C., Guedj, T., Cauquil, C., Assayag, P., Lambotte, O., Ducreux, D., & Denier, C. (2013) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2013.11.039 · Cited by 30
Wong, J., Lobato, R. L., Pinesett, A., Maxwell, B. G., Mangano, C. M., & Perez, M. V. (2014) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2014.04.034 · Cited by 28
Silent Atrial Fibrillation: A Critical Review.
Barbarossa, A., Guerra, F., & Capucci, A. (2014) · Europe PMC (PubMed Central) · doi:10.4022/jafib.1138 · Cited by 27
What every clinician should know about Bayés syndrome
Bayés‐Genís, A., Martínez‐Sellés, M., Bayés‐Genís, A., Elosúa, R., & Baranchuk, A. M. (2020) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2020.04.026 · Cited by 28
Scacciatella, P., Jorfida, M., Biava, L. M., Meynet, I., Zema, D., D’Ascenzo, F., Pristipino, C., Cerrato, P., Giustetto, C., & Gaïta, F. (2019) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000790 · Cited by 27
Ambulatory ECG monitoring in the age of smartphones
Sanders, D. J., Ungar, L. D. J., Eskander, M., & Seto, A. H. (2019) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.86a.18123 · Cited by 26
Frontzek, K., Fluri, F., Siemerkus, J., Müller, B., Gass, A., Christ‐Crain, M., & Mira, K. (2014) · PLoS ONE · doi:10.1371/journal.pone.0092421 · Cited by 25
Future of Implantable Devices for Cardiac Rhythm Management
Lau, C., Siu, C., & Tse, H. (2014) · Circulation · doi:10.1161/circulationaha.112.000312 · Cited by 25
North American Thrombosis Forum, AF Action Initiative Consensus Document
Ruff, C. T., Ansell, J., Becker, R. C., Benjamin, E. J., Deicicchi, D. J., Estes, N. A. M., Ezekowitz, M. D., Fanikos, J. R., Fareed, J., Garcia, D. A., et al. (2016) · The American Journal of Medicine · doi:10.1016/j.amjmed.2016.02.001 · Cited by 24
Edwards, S. J., Wakefield, V., Jhita, T., Kew, K. M., Cain, P., & Marceniuk, G. (2020) · Health Technology Assessment · doi:10.3310/hta24050 · Cited by 27
Baturova, M. A., Lindgren, A. G., Carlson, J., Shubik, Y. V., Olsson, S. B., & Platonov, P. G. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.07.047 · Cited by 25
Síndrome de Bayés. Lo que todo clínico debe conocer
Bayés‐Genís, A., Martínez‐Sellés, M., Bayés‐Genís, A., Elosúa, R., & Baranchuk, A. M. (2020) · Revista Española de Cardiología · doi:10.1016/j.recesp.2020.04.003 · Cited by 25
Kwok, C. S., Darlington, D., Mayer, J., Panchal, G., Walker, V., Zachariah, D., Phan, T., Mallen, C. D., Barker, D., & Patwala, A. (2022) · Hearts · doi:10.3390/hearts3020007 · Cited by 24
Patent Foramen Ovale and Cryptogenic Stroke: Integrated Management
Lucà, F., Pino, P. G., Parrini, I., Fusco, S. A. D., Ceravolo, R., Madeo, A., Leone, A., Meir, M. L., Benedetto, F. A., Riccio, C., et al. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12051952 · Cited by 25
Atrial Ectopic Activity in Cryptogenic Ischemic Stroke and TIA: A Risk Factor for Recurrence
Pinho, J., Braga, C. G., Rocha, S., Santos, A. F., Gomes, A., Cabreiro, A., Magalhães, S., & Ferreira, C. O. (2014) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2014.09.029 · Cited by 24
A Diagnostic Approach to Stroke in Young Adults
Stack, C. A., & Cole, J. W. (2017) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-017-0587-6 · Cited by 24
Embolic Stroke of Undetermined Source: Approaches in Risk Stratification for Cardioembolism
Bhat, A., Mahajan, V., Chen, H. H. L., Gan, G. C. H., Pontes-Neto, O. M., & Tan, T. C. (2021) · Stroke · doi:10.1161/strokeaha.121.034498 · Cited by 24
Ischemic Stroke Phenotype in Patients With Nonsustained Atrial Fibrillation
Arsava, E. M., Baş, D. F., Atalar, E., Has, A. C., Oğuz, K. K., & Topçuoğlu, M. A. (2015) · Stroke · doi:10.1161/strokeaha.114.006396 · Cited by 23
Performance of Atrial Fibrillation Detection in a New Single‐Chamber ICD
Deshmukh, A. J., BROWN, M. L., HIGGINS, E., SCHOUSEK, B., Abeyratne, A., Rovaris, G., & Friedman, P. A. (2016) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12918 · Cited by 23
Sinigaglia, M., Mahida, B., Piekarski, E., Chequer, R. D. P., Mikaïl, N., Benali, K., Hyafil, F., Guludec, D. L., & Rouzet, F. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-4274-6 · Cited by 23
Burkowitz, J., Merzenich, C., Grassme, K. S., & Brüggenjürgen, B. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487316632628 · Cited by 22
Rankin, A. J., & Rankin, S. H. (2017) · Clinical Medicine · doi:10.7861/clinmedicine.17-5-419 · Cited by 21
Makimoto, H., Kurt, M. M., Gliem, M., Lee, J., Schmidt, J., Müller, P., Clasen, L., Brinkmeyer, C., Shin, D., Jander, S., et al. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.007448 · Cited by 22
Refinement of detecting atrial fibrillation in stroke patients: results from the TRACK ‐ AF Study
Reinke, F., Bettin, M., Ross, L., Kochhäuser, S., Kleffner, I., Ritter, M., Minnerup, J., Dechering, D. G., Eckardt, L., & Dittrich, R. (2017) · European Journal of Neurology · doi:10.1111/ene.13538 · Cited by 22
Sanna, T., Ziegler, P., & Crea, F. (2018) · Clinical Cardiology · doi:10.1002/clc.22876 · Cited by 23
Tu, H., Spence, S., Kalman, J. M., & Davis, S. M. (2014) · Internal Medicine Journal · doi:10.1111/imj.12410 · Cited by 22
Bettin, M., Dechering, D. G., Kochhäuser, S., Bode, N., Eckardt, L., Frommeyer, G., & Reinke, F. (2018) · Clinical Research in Cardiology · doi:10.1007/s00392-018-1358-4 · Cited by 21
Mendieta, G., Guasch, E., Weir-Restrepo, D., Aristizábal-Colorado, D., Escobar‐Robledo, L. A., Llull, L., Mont, L., de Luna, A. B., & Sitges, M. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.11.050 · Cited by 21
Prognostic of Interatrial Block after an Acute ST-Segment Elevation Myocardial Infarction
Bruña, V., Velásquez‐Rodríguez, J., Valero‐Masa, M. J., Pérez-Guillem, B., Vicent, L., Díez‐Delhoyo, F., Devesa, C., Sousa-Casasnovas, I., Juárez, M., Bayés‐Genís, A., et al. (2019) · Cardiology · doi:10.1159/000499501 · Cited by 20
Wang, F., Ahat, X., Liang, Q., Ma, Y., Sun, M., Lin, L., Li, T., Duan, J., & Sun, Z. (2021) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2021.147106 · Cited by 20
Sanchís, L., Montserrat, S., Obach, V., Cervera, Á., Chamorro, Á., Vidal, B., Mas‐Stachurska, A., Bijnens, B. H., & Sitges, M. (2016) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2015.11.033 · Cited by 20
Current and Emerging Uses of Insertable Cardiac Monitors
Tomson, T. T., & PASSMAN, R. S. (2016) · Cardiology in Review · doi:10.1097/crd.0000000000000129 · Cited by 20
Electrocardiographic Predictors of Atrial Fibrillation
Chousou, P. A., Chattopadhyay, R. K., Tsampasian, V., Vassiliou, V. S., & Pugh, P. J. (2023) · Medical Sciences · doi:10.3390/medsci11020030 · Cited by 25
Self-citationPeripheral pulse measurement after ischemic stroke
Kallmünzer, B., Bobinger, T., Kahl, N., Kopp, M., Kurka, N., Hilz, M. J., Marquardt, L., Schwab, S., & Köhrmann, M. (2014) · Neurology · doi:10.1212/wnl.0000000000000690 · Cited by 19
Emerging Role of Digital Technology and Remote Monitoring in the Care of Cardiac Patients
Banchs, J. E., & Scher, D. M. (2015) · Medical Clinics of North America · doi:10.1016/j.mcna.2015.02.013 · Cited by 19
Metadata
- Authors
- Cotter, P. E., Martin, P. J., Ring, L., Warburton, E. A., Belham, M., & Pugh, P. J.
- Affiliations
- Cambridge University Hospitals NHS Foundation Trust (GB)
- Venue
- Neurology
- Published
- 2013-04-23
- Volume
- 80
- Issue
- 17
- Pages
- 1546-1550
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- PMC
- PMC3662328
- OpenAlex
- W2021263194
- Cited by
- 254
- References
- 19
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 10 · 2023: 11 · 2022: 18 · 2021: 25 · 2020: 11 · 2019: 21 · 2018: 18 · 2017: 21 · 2016: 26 · 2015: 29 · 2014: 44 · 2013: 9
- FWCI
- 24.45
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Neurology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Cardiovascular and Diving-Related Complications
- Health Sciences › Medicine › Clinical Neurology › Acute Ischemic Stroke Management
- Keywords
- atrial fibrillation, implantable loop recorder, cryptogenic stroke, patent foramen ovale, left atrial volume, premature atrial contractions, atrial fibrillation risk factors, cardiac rhythm monitoring
- MeSH terms
- Adolescent, Adult, Aged, Atrial Fibrillation, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Cohort Studies, Incidence, Stroke, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review