CoChat

Subtraction SPECT co-registered to MRI improves postictal SPECT localization of seizure foci

O’Brien, T.J., So, E.L., Mullan, B.P., Hauser, M.F., Brinkmann, B.H., Jack, C.R., Cascino, G.D., Meyer, F.B., Sharbrough, F.W. · 1999 · Neurology
Cited by 205

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To determine whether the detection of focal hypoperfusion by subtraction SPECT co-registered to MRI (SISCOM) improves the sensitivity and specificity of postictal SPECT in intractable partial epilepsy. BACKGROUND: Postictal SPECT injections are easier to perform than are ictal injections, but the images are more difficult to interpret and have been reported to have lower sensitivity and specificity. METHODS: Thirty-five consecutive intractable partial epilepsy patients who had postictal SPECT studies were evaluated. The following sets of SPECT images were separately interpreted by three blinded reviewers and classified as either localizing to 1 of 16 possible sites in the brain or as nonlocalizing: unsubtracted postictal and interictal images for conventional side-by-side comparison, SISCOM images of hyperperfusion, SISCOM images of hypoperfusion, and both sets of SISCOM hyperperfusion and hypoperfusion images (combined SISCOM evaluation). RESULTS: Significantly higher proportions of the hyperperfusion SISCOM images (65.7%), the hypoperfusion SISCOM images (74.3%), and the combined SISCOM evaluation (82.9%) were localizing than were the conventional method of side-by-side comparison of unsubtracted images (31.4%; p < 0.0001). Concordance with the discharge diagnosis was higher for the combined SISCOM evaluation than it was for either the hyperperfusion or the hypoperfusion SISCOM images alone (both p < 0.05). For the hypoperfusion SISCOM and the combined SISCOM evaluations, concordance of the localization with the site of epilepsy surgery was associated with a greater probability of an excellent outcome than were nonconcordant/nonlocalizing images (both p < 0.05). CONCLUSION: The use of SISCOM to detect focal cerebral hypoperfusion, in addition to focal hyperperfusion, improves the sensitivity and specificity of postictal SPECT in intractable partial epilepsy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/wnl.52.1.137

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 205

Metadata

Authors
O’Brien, T. J., So, E. L., Mullan, B. P., Hauser, M. F., Brinkmann, B. H., Jack, C. R., Cascino, G. D., Meyer, F. B., & Sharbrough, F. W.
Venue
Neurology
Published
1999-01
Volume
52
Issue
1
Pages
137-137
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W1985716571
Cited by
205
References
0
FWCI
9.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Subtraction SPECT co-registered to MRI improves postictal SPECT localization of seizure foci. https://app.cochat.ai/papers/10.1212/wnl.52.1.137
The paper
O’Brien, T. J., So, E. L., Mullan, B. P., Hauser, M. F., Brinkmann, B. H., Jack, C. R., Cascino, G. D., Meyer, F. B., & Sharbrough, F. W. (1999). Subtraction SPECT co-registered to MRI improves postictal SPECT localization of seizure foci. Neurology. https://doi.org/10.1212/wnl.52.1.137

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.