Subtraction SPECT co-registered to MRI improves postictal SPECT localization of seizure foci
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine whether the detection of focal hypoperfusion by subtraction SPECT co-registered to MRI (SISCOM) improves the sensitivity and specificity of postictal SPECT in intractable partial epilepsy. BACKGROUND: Postictal SPECT injections are easier to perform than are ictal injections, but the images are more difficult to interpret and have been reported to have lower sensitivity and specificity. METHODS: Thirty-five consecutive intractable partial epilepsy patients who had postictal SPECT studies were evaluated. The following sets of SPECT images were separately interpreted by three blinded reviewers and classified as either localizing to 1 of 16 possible sites in the brain or as nonlocalizing: unsubtracted postictal and interictal images for conventional side-by-side comparison, SISCOM images of hyperperfusion, SISCOM images of hypoperfusion, and both sets of SISCOM hyperperfusion and hypoperfusion images (combined SISCOM evaluation). RESULTS: Significantly higher proportions of the hyperperfusion SISCOM images (65.7%), the hypoperfusion SISCOM images (74.3%), and the combined SISCOM evaluation (82.9%) were localizing than were the conventional method of side-by-side comparison of unsubtracted images (31.4%; p < 0.0001). Concordance with the discharge diagnosis was higher for the combined SISCOM evaluation than it was for either the hyperperfusion or the hypoperfusion SISCOM images alone (both p < 0.05). For the hypoperfusion SISCOM and the combined SISCOM evaluations, concordance of the localization with the site of epilepsy surgery was associated with a greater probability of an excellent outcome than were nonconcordant/nonlocalizing images (both p < 0.05). CONCLUSION: The use of SISCOM to detect focal cerebral hypoperfusion, in addition to focal hyperperfusion, improves the sensitivity and specificity of postictal SPECT in intractable partial epilepsy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
A Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398
Single photon-emission computed tomography
Holly, T. A., Abbott, B. G., Al-Mallah, M., Calnon, D. A., Cohen, M. C., DiFilippo, F. P., Ficaro, E. P., Freeman, M. R., Hendel, R. C., Jain, D., et al. (2010) · Journal of Nuclear Cardiology · doi:10.1007/s12350-010-9246-y · Cited by 597
Guideline Thirteen: Guidelines for Standard Electrode Position Nomenclature
&NA; (1994) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199401000-00014 · Cited by 556
O'Brien, T. J., So, E. L., Mullan, B. P., Hauser, M. F., Brinkmann, B. H., Bohnen, N. I., Hanson, D., Cascino, G. D., Jack, C. R., & Sharbrough, F. W. (1998) · Neurology · doi:10.1212/wnl.50.2.445 · Cited by 530
Self-citationThe Relative Contributions of MRI, SPECT, and PET Imaging in Epilepsy
Spencer, S. S. (1994) · Epilepsia · doi:10.1111/j.1528-1157.1994.tb05990.x · Cited by 379
SPECT brain imaging in epilepsy: a meta-analysis.
Devous, M. D., Thisted, R. A., Morgan, G. F., Leroy, R. F., & Rowe, C. C. (1998) · PubMed · Cited by 231
Rowe, C. C., Berkovic, S. F., Austin, M. C., McKay, W. J., & Bladin, P. F. (1991) · Neurology · doi:10.1212/wnl.41.7.1096 · Cited by 217
OʼBRIEN, T., OʼCONNOR, M. K., MULLAN, B. P., BRINKMANN, B. H., HANSON, D., JACK, C. R., & SO, E. L. (1998) · Nuclear Medicine Communications · doi:10.1097/00006231-199801000-00006 · Cited by 182
Self-citationPostictal switch in blood flow distribution and temporal lobe seizures.
Newton, M. R., Berkovic, S. F., Austin, M. C., Rowe, C. C., McKay, W. J., & Bladin, P. F. (1992) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.55.10.891 · Cited by 178
Cited by
Thijs, R. D., Surges, R., O'Brien, T. J., & Sander, J. W. (2019) · The Lancet · doi:10.1016/s0140-6736(18)32596-0 · Cited by 2,183
Self-citationDonepezil improved memory in multiple sclerosis in a randomized clinical trial
Krupp, L. B., Christodoulou, C., Melville, P., Scherl, W. F., MacAllister, W. S., & Elkins, L. E. (2004) · Neurology · doi:10.1212/01.wnl.0000142989.09633.5a · Cited by 300
Subtraction peri-ictal SPECT is predictive of extratemporal epilepsy surgery outcome
O’Brien, T. J., So, E. L., Mullan, B. P., Cascino, G. D., Hauser, M. F., Brinkmann, B. H., Sharbrough, F. W., & Meyer, F. B. (2000) · Neurology · doi:10.1212/wnl.55.11.1668 · Cited by 224
Self-citationImaging in the surgical treatment of epilepsy
Duncan, J. S. (2010) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.131 · Cited by 219
(2016) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-53486-6.00051-x · Cited by 169
“These changes are widespread and nonspecific, but it has been shown that early postictal SPECT scans can be used in seizure localization or at least in lateralization of seizure (O’Brien et al., 1999; McNally et al., 2005).”
BackgroundPrognostic Factors in Neocortical Epilepsy Surgery: Multivariate Analysis
Yun, C., Lee, S. K., Lee, S. Y., Kim, K. K., Jeong, S. W., & Chung, C. (2006) · Epilepsia · doi:10.1111/j.1528-1167.2006.00470.x · Cited by 160
Metadata
- Authors
- O’Brien, T. J., So, E. L., Mullan, B. P., Hauser, M. F., Brinkmann, B. H., Jack, C. R., Cascino, G. D., Meyer, F. B., & Sharbrough, F. W.
- Venue
- Neurology
- Published
- 1999-01
- Volume
- 52
- Issue
- 1
- Pages
- 137-137
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W1985716571
- Cited by
- 205
- References
- 15
- FWCI
- 9.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.