Diffusion-perfusion MR evaluation of perihematomal injury in hyperacute intracerebral hemorrhage
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
BACKGROUND: It has been suggested that a zone of perihematomal ischemia analogous to an ischemic penumbra exists in patients with primary intracerebral hemorrhage (ICH). Diffusion-perfusion MRI provides a novel means of assessing injury in perihematomal regions in patients with ICH. OBJECTIVE: To characterize diffusion-perfusion MRI changes in the perihematomal region in patients with hyperacute intracerebral hemorrhage. METHOD: Twelve patients presenting with hyperacute, primary ICH undergoing CT scanning and diffusion-perfusion MRI within 6 hours of symptom onset were reviewed. An automated thresholding technique was used to identify decreased apparent diffusion coefficient (ADC) values in the perihematomal regions. Perfusion maps were examined for regions of relative hypo- or hyperperfusion. RESULTS: Median baseline NIH Stroke Scale score was 17 (range, 6 to 28). Median hematoma volume was 13.3 mL (range, 3.0 to 74.8 mL). MRI detected the hematoma in all patients on echo-planar susceptibility-weighted imaging and in all seven patients imaged with gradient echo sequences. In six patients who underwent perfusion imaging, no focal defects were visualized on perfusion maps in tissues adjacent to the hematoma; however, five of six patients demonstrated diffuse ipsilateral hemispheric hypoperfusion. On diffusion imaging, perihematomal regions of decreased ADC values were identified in three of 12 patients. All three subsequently showed clinical and radiologic deterioration. CONCLUSIONS: A rim of perihematomal decreased ADC values was visualized in the hyperacute period in a subset of patients with ICH. The presence of a rim of decreased ADC outside the hematoma correlated with poor clinical outcome. Although perfusion maps did not demonstrate a focal zone of perihematomal decreased blood flow in any patient, most patients had ipsilateral hemispheric hypoperfusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The ABCs of Measuring Intracerebral Hemorrhage Volumes
Kothari, R. U., Brott, T., Broderick, J. P., Barsan, W. G., Sauerbeck, L. R., Zuccarello, M., & Khoury, J. (1996) · Stroke · doi:10.1161/01.str.27.8.1304 · Cited by 2,222
Automated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
Woods, R. P., Grafton, S. T., Holmes, C. J., Cherry, S. R., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00027 · Cited by 1,707 · cited 1×
“Mean systolic blood pressure (SD) 184 (41) mm Hg 160 (30) mm Hg NS”
BackgroundØstergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Acute human stroke studied by whole brain echo planar diffusion‐weighted magnetic resonance imaging
Warach, S., Gaa, J., Siewert, B., Wielopolski, P., & Edelman, R. R. (1995) · Annals of Neurology · doi:10.1002/ana.410370214 · Cited by 1,004
Self-citationThe Stroke Data Bank: design, methods, and baseline characteristics.
Foulkes, M. A., Wolf, P. A., Price, T. R., Mohr, J. P., & Hier, D. B. (1988) · Stroke · doi:10.1161/01.str.19.5.547 · Cited by 946
Broderick, J. P., Adams, H. P., Barsan, W., Feinberg, W., Feldmann, E., Grotta, J., Kase, C., Krieger, D., Mayberg, M., Tilley, B., et al. (1999) · Stroke · doi:10.1161/01.str.30.4.905 · Cited by 830
Østergaard, L., Sorensen, A. G., Kwong, K. K., Weisskoff, R. M., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360511 · Cited by 810
Kidwell, C. S., Saver, J. L., Mattiello, J., Starkman, S., Vinuela, F., Duckwiler, G., Gobin, Y. P., Jahan, R., Vespa, P., Kalafut, M., et al. (2000) · Annals of Neurology · doi:10.1002/1531-8249(200004)47:4<462::aid-ana9>3.0.co;2-y · Cited by 692
Self-citation(2010) · Handbook of Disease Burdens and Quality of Life Measures · doi:10.1007/978-0-387-78665-0_5946 · Cited by 665
The ischemic penumbra: Operationally defined by diffusion and perfusion MRI
Schlaug, G., Benfield, A., Baird, A. E., Siewert, B., Lövblad, K. O., Parker, R. A., Edelman, R. R., & Warach, S. (1999) · Neurology · doi:10.1212/wnl.53.7.1528 · Cited by 663
Self-citation
Cited by
Broderick, J., Connolly, S., Feldmann, E., Hanley, D., Kase, C., Krieger, D., Mayberg, M., Morgenstern, L., Ogilvy, C. S., Vespa, P., et al. (2007) · Stroke · doi:10.1161/strokeaha.107.183689 · Cited by 1,125
Self-citationComparison of MRI and CT for Detection of Acute Intracerebral Hemorrhage
Kidwell, C. S. (2004) · JAMA · doi:10.1001/jama.292.15.1823 · Cited by 824
Self-citationAcute seizures after intracerebral hemorrhage: A factor in progressive midline shift and outcome
Vespa, P. M., O’Phelan, K., Shah, M., Mirabelli, J., Starkman, S., Kidwell, C., Saver, J., Nuwer, M. R., Frazee, J. G., McArthur, D. A., et al. (2003) · Neurology · doi:10.1212/01.wnl.0000063316.47591.b4 · Cited by 561
Self-citationFiebach, J. B., Schellinger, P. D., Gass, A., Kucinski, T., Siebler, M., Villringer, A., Ölkers, P., Hirsch, J. G., Heiland, S., Wilde, P., et al. (2004) · Stroke · doi:10.1161/01.str.0000114203.75678.88 · Cited by 434
Real‐time diffusion‐perfusion mismatch analysis in acute stroke
Straka, M., Albers, G. W., & Bammer, R. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22338 · Cited by 401
Mould, W. A., Carhuapoma, J. R., Muschelli, J., Lane, K., Morgan, T. C., McBee, N. A., Bistran-Hall, A. J., Ullman, N. L., Vespa, P., Martin, N. A., et al. (2013) · Stroke · doi:10.1161/strokeaha.111.000411 · Cited by 366
Self-citationBroderick, J., Connolly, S., Feldmann, E., Hanley, D., Kase, C., Krieger, D., Mayberg, M., Morgenstern, L., Ogilvy, C. S., Vespa, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.183689 · Cited by 357
Self-citationImaging of intracranial haemorrhage
Kidwell, C. S., & Wintermark, M. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70041-3 · Cited by 240
Self-citationPerihematomal Edema in Primary Intracerebral Hemorrhage Is Plasma Derived
Butcher, K. S., Baird, T., MacGregor, L., Desmond, P., Tress, B., & Davis, S. (2004) · Stroke · doi:10.1161/01.str.0000131807.54742.1a · Cited by 198
Metadata
- Authors
- Kidwell, C. S., Saver, J. L., Mattiello, J., Warach, S., Liebeskind, D. S., Starkman, S., Vespa, P. M., Villablanca, J. P., Martin, N. A., Frazee, J., & Alger, J. R.
- Venue
- Neurology
- Published
- 2001-11-13
- Volume
- 57
- Issue
- 9
- Pages
- 1611-1617
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2078772975
- Cited by
- 158
- References
- 34
- FWCI
- 4.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.