Pulse Oximetry and Circulatory Kinetics Associated with Pulse Volume Amplitude Measured by Photoelectric Plethysmography
The DOI matches its Crossref record.
Abstract
Through a catheter placed in a superficial vein on the finger, we observed a pulsatile venous pressure. To delineate the relationship between the pulsatile venous pressure and the pulse volume amplitude (PVA) recorded by photoelectric plethysmography (PEPG), both tracings were simultaneously recorded. When the PVA changed acutely or gradually, the venous pulse pressure and mean venous pressure simultaneously followed the same trend. We also found that mean PVO2 (135 mm Hg) was greater when the PVA and venous pulse pressure increased above the level (50 mm Hg) observed when they decreased. These findings suggested that the finger pulse detected by PEPG, as well as by pulse oximetry, is caused by pulsations in veins rather than by pulsations in arterial beds. In experiments to evaluate the validity of this hypothesis, we found that the average value of hemoglobin saturation (%SaO2) measured by the pulse oximeter of the dependent fingertip and finger base when dependent was 1.5% and 7.8% lower than when the fingertip and finger base were elevated. Also, the PVA detected by the pulse oximeter followed the same trend as %SaO2. This finding was explained by venous congestion in the dependent finger. On the basis of the high venous pressure, the behavioral trends between the PVA and venous pressure, the high PVO2, and the low %SaO2 and PVA in the dependent finger, we conclude that the PVA of the PEPG is determined mainly by venous pulse volume generated by shunting of arterial pulse via open arteriovenous (AV) anastomoses in the cutaneous circulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate
Shelley, K. H. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269512.82836.c9 · Cited by 450
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 366
Alian, A. A., & Shelley, K. H. (2014) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2014.08.006 · Cited by 289
“On the other hand, others hypothesized that the source of the signal is from “open arteriovenous anastomoses in the cutaneous circulation” [6].”
BackgroundMeta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
Jensen, L. A., Onyskiw, J. E., & Prasad, N. G. N. (1998) · Heart & Lung · doi:10.1016/s0147-9563(98)90086-3 · Cited by 243
Photoplethysmographic derivation of respiratory rate: A review of relevant physiology
Meredith, D. J., Clifton, D., Charlton, P., Brooks, J., Pugh, C. W., & Tarassenko, L. (2012) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2011.638965 · Cited by 226
Metadata
- Authors
- Kim, J.-M., Arakawa, K., Benson, K. T., & Fox, D. K.
- Venue
- Anesthesia & Analgesia
- Published
- 1986-12
- Volume
- 65
- Issue
- 12
- Pages
- 1333???1339
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2057637702
- Cited by
- 86
- References
- 0
- FWCI
- 4.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulse Oximetry and Circulatory Kinetics Associated with Pulse Volume Amplitude Measured by Photoelectric Plethysmography. https://app.cochat.ai/papers/10.1213/00000539-198612000-00015
- The paper
- Kim, J.-M., Arakawa, K., Benson, K. T., & Fox, D. K. (1986). Pulse Oximetry and Circulatory Kinetics Associated with Pulse Volume Amplitude Measured by Photoelectric Plethysmography. Anesthesia & Analgesia. https://doi.org/10.1213/00000539-198612000-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.