Human Auditory Steady-State Response During General Anesthesia
The DOI matches its Crossref record.
Abstract
The 40-Hz auditory steady-state evoked response (ASSR) is a sinusoidal electrical response of the brain to periodically presented auditory stimuli. It was recorded during anesthesia in 10 elective surgical patients to evaluate its usefulness as a measure of the level of consciousness. The anesthetic agents used were thiopental, fentanyl, and isoflurane with or without nitrous oxide. Recordings were carried out during the period before induction and during induction, surgical anesthesia, emergence, and recovery from anesthesia. The level of consciousness was measured with an auditory stimulus detection task. The electroencephalogram (EEG) was also recorded for comparison with the ASSR. The following indices were analyzed: total EEG power, relative power in the beta, alpha, theta, and delta frequency bands, and the median and spectral edge frequency. The amplitude of the ASSR was reduced significantly at the end of the induction period and decreased below noise levels during surgical anesthesia. It increased significantly during emergence and recovery. The amplitude during recovery remained significantly smaller than the preinduction values. The changes of the ASSR paralleled those of the level of consciousness. The EEG measurements were distorted by the presence of muscle artifacts that were prominent during emergence and recovery. The amplitude of the ASSR appears to provide a more reliable indicator of the level of consciousness than the EEG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Human auditory steady-state responses: Respuestas auditivas de estado estable en humanos
Picton, T. W., John, M. S., Dimitrijevic, A., & Purcell, D. (2003) · International Journal of Audiology · doi:10.3109/14992020309101316 · Cited by 846
Self-citationFiset, P., Paus, T., Daloze, T., Plourde, G., Meuret, P., Bonhomme, V., Hajj-Ali, N., Backman, S. B., & Evans, A. C. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-13-05506.1999 · Cited by 475
“Furthermore, thalamocortical interactions expressed, for example, as 40 Hz oscillations are decreased in natural sleep (L linás and Paré, 1991) and during general anesthesia (Plourde and Picton, 1990; Plourde and Boylan , 1991; Plourde et al., 1998).”
BackgroundSelf-citationAuditory steady-state responses to multiple simultaneous stimuli
Lins, O. G., & Picton, T. W. (1995) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(95)00048-w · Cited by 300
Self-citationBanoub, M., Tetzlaff, J. E., & Schubert, A. (2003) · Anesthesiology · doi:10.1097/00000542-200309000-00029 · Cited by 299
“Opioids, even in very large doses, are less reliable in suppressing consciousness and sensory information processing than are volatile anesthetics.(142,158,159) This is consistent with clinical reports of intraoperative awareness and perception of auditory stimuli if opioids are used exclusively for general anesthesia.”
BackgroundHuman temporal auditory acuity as assessed by envelope following responses
Purcell, D. W., John, S. M., Schneider, B. A., & Picton, T. W. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1798354 · Cited by 282
Self-citation
Metadata
- Authors
- Plourde, G., & Picton, T. W.
- Venue
- Anesthesia & Analgesia
- Published
- 1990-11
- Volume
- 71
- Issue
- 5
- Pages
- 460???468
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2043210702
- Cited by
- 137
- References
- 0
- FWCI
- 4.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human Auditory Steady-State Response During General Anesthesia. https://app.cochat.ai/papers/10.1213/00000539-199011000-00002
- The paper
- Plourde, G., & Picton, T. W. (1990). Human Auditory Steady-State Response During General Anesthesia. Anesthesia & Analgesia. https://doi.org/10.1213/00000539-199011000-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.