Cervical Spine Motion: A Fluoroscopic Comparison During Intubation with Lighted Stylet, GlideScope, and Macintosh Laryngoscope
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
In Brief The question of which is the optimum technique to intubate the trachea in a patient who may have a cervical(C)-spine injury remains unresolved. We compared, using fluoroscopic video, C-spine motion during intubation for Macintosh 3 blade, GlideScope®, and Intubating Lighted Stylet, popularly known as the Lightwand or Trachlight®. Thirty-six healthy patients were randomized to participate in a crossover trial of either Lightwand or GlideScope to Macintosh laryngoscopy, with in-line stabilization. C-spine motion was examined at the Occiput-C1 junction, C1-2 junction, C2-5 motion segment, and C5-thoracic motion segment during manual ventilation via bag-mask, laryngoscopy, and intubation. Time to intubate was also measured. C-spine motion during bag-mask ventilation was 82% less at the four motion segments studied than during Macintosh laryngoscopy (P < 0.001). C-spine motion using the Lightwand was less than during Macintosh laryngoscopy, averaging 57% less at the four motion segments studied (P < 0.03). There was no significant difference in time to intubate between the Lightwand and the Macintosh blade. C-spine motion was reduced 50% at the C2-5 segment using the GlideScope (P < 0.04) but unchanged at the other segments. Laryngoscopy with GlideScope took 62% longer than with the Macintosh blade (P < 0.01). Thus, the Lightwand (Intubating Lighted Stylet) is associated with reduced C-spine movement during endotracheal intubation compared with the Macintosh laryngoscope. IMPLICATIONS: The question of which is the optimum technique to intubate the trachea of a patient who may have a cervical(C)-spine injury remains unresolved. Using fluoroscopic video, C-spine motion during intubation was compared for Macintosh 3 blade, GlideScope, and Lightwand use. The Lightwand is associated with reduced C-spine movement during intubation compared to Macintosh laryngoscope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Difficult tracheal intubation in obstetrics
CORMACK, R. S., & LEHANE, J. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb08932.x · Cited by 2,471
Use of a new videolaryngoscope (GlideScope®) in the management of a difficult airway
Cooper, R. M. (2003) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03018651 · Cited by 244 · cited 1×
“The GlideScope was used as per the instructions provided by the manufacturer (15,16).”
MethodBrimacombe, J. R., & Berry, A. M. (1997) · Canadian Journal of Anaesthesia · doi:10.1007/bf03014464 · Cited by 213
Sawin, P. D., Todd, M. M., Traynelis, V. C., Farrell, S. B., Nader, A., Sato, Y., Clausen, J. D., & Goel, V. K. (1996) · Anesthesiology · doi:10.1097/00000542-199607000-00005 · Cited by 194 · cited 3×
“Extension was arbitrarily defined as positive and flexion as negative (7).”
BackgroundInfluentialBrimacombe, J., Keller, C., Künzel, K. H., Gaber, O., Boehler, M., & Pühringer, F. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200011000-00041 · Cited by 185
Lennarson, P. J., Smith, D. W., Sawin, P. D., Todd, M. M., Sato, Y., & Traynelis, V. C. (2001) · Journal of Neurosurgery: Spine · doi:10.3171/spi.2001.94.2.0265 · Cited by 156 · cited 1×
“It is possible, however, that with stabilization of the Oc, the manipulation of the airway required to obtain an adequate view may result in increased C-spine motion at other segments (6,18).”
BackgroundAgrò, F. E., Barzoi, G., & Montecchia, F. (2003) · British Journal of Anaesthesia · doi:10.1093/bja/aeg560 · Cited by 153 · cited 2×
“(10) compared quality of laryngeal view using the GlideScope versus the Macintosh blade, with in-line stabilization provided, but C-spine movement was not assessed.”
BackgroundWatts, A. D. J., Gelb, A. W., Bach, D. B., & Pelz, D. M. (1997) · Anesthesiology · doi:10.1097/00000542-199712000-00012 · Cited by 143 · cited 2×
“This suggests a potential advantage of the Lightwand over fiberoptic intubation or use of the Bullard laryngoscope, both of which have been shown to reduce C-spine motion at the cost of significantly longer times to intubate (1,8,19).”
BackgroundSelf-citationCervical Spine Movement during Laryngoscopy with the Bullard, Macintosh, and Miller Laryngoscopes
Hastings, R. H., Vigil, A. C., Hanna, R., Yang, B.-Y., & Sartoris, D. J. (1995) · Anesthesiology · doi:10.1097/00000542-199504000-00007 · Cited by 141
Lennarson, P. J., Smith, D., Todd, M. M., Carras, D., Sawin, P. D., Brayton, J., Sato, Y., & Traynelis, V. C. (2000) · Journal of Neurosurgery: Spine · doi:10.3171/spi.2000.92.2.0201 · Cited by 127
Cervical spine movement during airway management: Cinefluoroscopic appraisal in human cadavers
Hauswald, M., Sklar, D. P., Tandberg, D., & Garcia, J. F. (1991) · The American Journal of Emergency Medicine · doi:10.1016/0735-6757(91)90106-t · Cited by 97 · cited 2×
“As only one radiograph was used in that study, the maximal excursion may not have been seen (5).”
BackgroundMethodTracheal intubation and cervical spine excursion: direct laryngoscopy vs. intubating laryngeal mask
Waltl, B., Melischek, M., Schuschnig, C., Kabon, B., Erlacher, W., Našel, C., Fuchs, M., & Kapral, S. (2001) · Anaesthesia · doi:10.1046/j.1365-2044.2001.01869.x · Cited by 62
Cosan, T. E., Gücüyener, D., Dündar, E., Arslantas, A., Vural, M., Uzuner, K., & Tel, E. (2001) · Journal of neurosurgery · doi:10.3171/jns.2001.94.2.0265 · Cited by 60
Airway management after upper cervical spine injury: what have we learned?
Crosby, E. T. (2002) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03017455 · Cited by 53 · cited 2×
“Endotracheal intubation is frequently required for trauma patients as part of the resuscitative effort (1) or for patients with unstable cervical spine (C-spine) requiring surgery (2).”
BackgroundMethod
Cited by
Airway management in adults after cervical spine trauma
Crosby, E. T., & Warltier, D. C. (2006) · Anesthesiology · doi:10.1097/00000542-200606000-00026 · Cited by 401
Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., & Smith, A. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011136.pub2 · Cited by 374
Griesdale, D. E. G., Liu, D., McKinney, J., & Choi, P. T. (2012) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-011-9620-5 · Cited by 363
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., Schofield-Robinson, O. J., & Smith, A. F. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex228 · Cited by 359
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
Self-citation
Metadata
- Authors
- Turkstra, T. P., Craen, R. A., Pelz, D. M., & Gelb, A. W.
- Venue
- Anesthesia & Analgesia
- Published
- 2005-09
- Volume
- 101
- Issue
- 3
- Pages
- 910-915
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W1971588014
- Cited by
- 238
- References
- 14
- FWCI
- 11.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).