CoChat

Temporal Artery Versus Bladder Thermometry During Perioperative and Intensive Care Unit Monitoring

Kimberger, Oliver, Cohen, Delphine, Illievich, Udo, Lenhardt, Rainer · 2007 · Anesthesia & Analgesia
Cited by 71

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Core temperature measurements are an important component of perioperative patient monitoring. It is fairly easy to obtain core temperature measurements invasively in anesthetized patients. However, such measurements are more difficult to obtain noninvasively in awake patients. Recently, a new version of a temporal artery thermometer for noninvasive core temperature measurements (TemporalScanner TAT-5000) was introduced with accuracy and precision advertised as being comparable to invasive core temperature measurements. In this study, we sought to determine if this new thermometer is an acceptable substitute for invasive bladder temperature measurement. METHODS: In 35 patients undergoing neurosurgical interventions and 35 patients in the neurosurgical intensive care unit, measurements from the temporal artery thermometer were compared with those from a bladder thermometer. Four measurements were obtained from each patient. RESULTS: Overall 280 measurement pairs were obtained. The mean bias between the methods was 0.07 degrees C +/- 0.79 degrees C; the limits of agreement were approximately 3 times greater than the a priori defined limit of +/-0.5 degrees C (-1.48 to 1.62). The sensitivity for detecting fever (core temperature >37.8 degrees C) using the temporal artery thermometer was 0.72, and the specificity was 0.97. The positive predictive value for fever was 0.89; the negative predictive value was 0.94. The sensitivity for detecting hypothermia (core temperature <35.5 degrees C) was 0.29, and the specificity was 0.95. The positive predictive value for hypothermia was 0.31, and the negative predictive value was 0.95. CONCLUSIONS: The results of this study do not support the use of temporal artery thermometry for perioperative core temperature monitoring; the temporal artery thermometer does not provide information that is an adequate substitute for core temperature measurement by a bladder thermometer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/01.ane.0000281927.88935.e0

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 71

Metadata

Authors
Kimberger, O., Cohen, D., Illievich, U., & Lenhardt, R.
Venue
Anesthesia & Analgesia
Published
2007-10
Volume
105
Issue
4
Pages
1042-1047
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2081214428
Cited by
71
References
2
FWCI
2.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Temporal Artery Versus Bladder Thermometry During Perioperative and Intensive Care Unit Monitoring. https://app.cochat.ai/papers/10.1213/01.ane.0000281927.88935.e0
The paper
Kimberger, O., Cohen, D., Illievich, U., & Lenhardt, R. (2007). Temporal Artery Versus Bladder Thermometry During Perioperative and Intensive Care Unit Monitoring. Anesthesia & Analgesia. https://doi.org/10.1213/01.ane.0000281927.88935.e0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.