Portable Infrared Pupillometry: A Review
Abstract
Portable infrared pupillometers provide an objective measure of pupil size and pupillary reflexes, which for most clinicians was previously only a visual impression. But despite the fact that pupillometry can uncover aspects of how the human pupil reacts to drugs and noxious stimulation, the use of pupillometry has not gained widespread use among anesthesiologists and critical care physicians. The present review is an introduction to the physiology of pupillary reflexes and the currently established clinical applications of infrared pupillometry, which will hopefully encourage physicians to use this diagnostic tool in their clinical practice. Portable infrared pupillometry was introduced in 1989. The technology involves flooding the eye with infrared light and then measuring the reflected image on an infrared sensor. Pupil size, along with variables of the pupillary light reflex and pupillary reflex dilation, is calculated by the instrument and displayed on a screen immediately after each time-stamped measurement. Use of these instruments has uncovered aspects of how the human pupil reacts to drugs and noxious stimulation. The primary clinical applications for portable pupillometry have been in the assessment of brainstem function. Portable pupillometry is useful in the management of pain because it allows for assessments of the effect of opioids and in the titration of combined regional-general anesthetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aston-Jones, G., & Cohen, J. D. (2005) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.28.061604.135709 · Cited by 4,472
Human and macaque pupil responses driven by melanopsin-containing retinal ganglion cells
Gamlin, P. D. R., McDougal, D. H., Pokorny, J., Smith, V. C., Yau, K.-W., & Dacey, D. M. (2007) · Vision Research · doi:10.1016/j.visres.2006.12.015 · Cited by 617
Cited by
Severe traumatic brain injury: targeted management in the intensive care unit
Stocchetti, N., Carbonara, M., Citerio, G., Ercole, A., Skrifvars, M. B., Smielewski, P., Zoerle, T., & Menon, D. K. (2017) · The Lancet Neurology · doi:10.1016/s1474-4422(17)30118-7 · Cited by 444
Winn, M. B., Wendt, D., Koelewijn, T., & Kuchinsky, S. E. (2018) · Trends in Hearing · doi:10.1177/2331216518800869 · Cited by 339
Oddo, M., Sandroni, C., Citerio, G., Miroz, J.-P., Horn, J., Rundgren, M., Cariou, A., Payen, J.-F., Storm, C., Stammet, P., et al. (2018) · Intensive Care Medicine · doi:10.1007/s00134-018-5448-6 · Cited by 262
An introduction into autonomic nervous function
Karemaker, J. M. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6782 · Cited by 259
Metadata
- Authors
- Larson, M. D., & Behrends, M.
- Venue
- Anesthesia & Analgesia
- Published
- 2015-06
- Volume
- 120
- Issue
- 6
- Pages
- 1242-1253
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2336988105
- Cited by
- 242
- References
- 2
- FWCI
- 18.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Portable Infrared Pupillometry: A Review. https://app.cochat.ai/papers/10.1213/ane.0000000000000314
- The paper
- Larson, M. D., & Behrends, M. (2015). Portable Infrared Pupillometry: A Review. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0000000000000314