Portable Infrared Pupillometry: A Review
The DOI matches its Crossref record; 106 of the 106 references it cites were found in a registry or an index.
Abstract
Portable infrared pupillometers provide an objective measure of pupil size and pupillary reflexes, which for most clinicians was previously only a visual impression. But despite the fact that pupillometry can uncover aspects of how the human pupil reacts to drugs and noxious stimulation, the use of pupillometry has not gained widespread use among anesthesiologists and critical care physicians. The present review is an introduction to the physiology of pupillary reflexes and the currently established clinical applications of infrared pupillometry, which will hopefully encourage physicians to use this diagnostic tool in their clinical practice. Portable infrared pupillometry was introduced in 1989. The technology involves flooding the eye with infrared light and then measuring the reflected image on an infrared sensor. Pupil size, along with variables of the pupillary light reflex and pupillary reflex dilation, is calculated by the instrument and displayed on a screen immediately after each time-stamped measurement. Use of these instruments has uncovered aspects of how the human pupil reacts to drugs and noxious stimulation. The primary clinical applications for portable pupillometry have been in the assessment of brainstem function. Portable pupillometry is useful in the management of pain because it allows for assessments of the effect of opioids and in the titration of combined regional-general anesthetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These systems can analyze changes in pupil diameter at the millisecond level and evaluate multiple parameters, such as maximum and minimum pupil diameter, constriction and dilation velocities, latency, and symmetry, using standardized protocols (8,29).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [29]
In the citing paper
“Nevertheless, the high cost of devices and their limited availability across clinical settings remain major factors restricting the widespread use of quantitative pupillometry (29,38).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [29]
In the citing paper
“In recent years, pupillometric parameters such as the Pupillary Pain Index (PPI) and constriction velocity/latency have been reported as reliable indicators that assist in ensuring intraoperative and postoperative analgesia and in assessing pain severity (29,37,(49)(50)(51).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [29]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aston-Jones, G., & Cohen, J. D. (2005) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.28.061604.135709 · Cited by 4,472
Codeine Intoxication Associated with Ultrarapid CYP2D6 Metabolism
Gasche, Y., Daali, Y., Fathi, M., Chiappe, A., Cottini, S., Dayer, P., & Desmeules, J. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041888 · Cited by 702
Physiology and Pathophysiology of the Human Sympathoadrenal Neuroendocrine System
Bleich, H. L., Moore, M. J., & Cryer, P. E. (1980) · New England Journal of Medicine · doi:10.1056/nejm198008213030806 · Cited by 652
Human and macaque pupil responses driven by melanopsin-containing retinal ganglion cells
Gamlin, P. D. R., McDougal, D. H., Pokorny, J., Smith, V. C., Yau, K.-W., & Dacey, D. M. (2007) · Vision Research · doi:10.1016/j.visres.2006.12.015 · Cited by 617
How opioids inhibit GABA-mediated neurotransmission
Vaughan, C. W., Ingram, S. L., Connor, M. A., & Christie, M. J. (1997) · Nature · doi:10.1038/37610 · Cited by 507
Predicting the Outcome From Hypoxic-Ischemic Coma
Jorgensen, E. O. (1986) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1986.03370120043011 · Cited by 494
Predicting Outcome From Hypoxic-lschemic Coma
Levy, D. E. (1985) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1985.03350340072020 · Cited by 432
A unified formula for light-adapted pupil size
Watson, A. B., & Yellott, J. I. (2012) · Journal of Vision · doi:10.1167/12.10.12 · Cited by 399
Chen, J., Gombart, Z., Rogers, S., Gardiner, S., Cecil, S., & Bullock, R. (2011) · Surgical Neurology International · doi:10.4103/2152-7806.82248 · Cited by 314
Melanopsin signalling in mammalian iris and retina
Xue, T., Do, M. T. H., Riccio, A., Jiang, Z., Hsieh, J., Wang, H. C., Merbs, S. L., Welsbie, D. S., Yoshioka, T., Weissgerber, P., et al. (2011) · Nature · doi:10.1038/nature10567 · Cited by 303
Cited by
Severe traumatic brain injury: targeted management in the intensive care unit
Stocchetti, N., Carbonara, M., Citerio, G., Ercole, A., Skrifvars, M. B., Smielewski, P., Zoerle, T., & Menon, D. K. (2017) · The Lancet Neurology · doi:10.1016/s1474-4422(17)30118-7 · Cited by 444
Winn, M. B., Wendt, D., Koelewijn, T., & Kuchinsky, S. E. (2018) · Trends in Hearing · doi:10.1177/2331216518800869 · Cited by 339
Oddo, M., Sandroni, C., Citerio, G., Miroz, J.-P., Horn, J., Rundgren, M., Cariou, A., Payen, J.-F., Storm, C., Stammet, P., et al. (2018) · Intensive Care Medicine · doi:10.1007/s00134-018-5448-6 · Cited by 262
An introduction into autonomic nervous function
Karemaker, J. M. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6782 · Cited by 259
Couret, D., Boumaza, D., Grisotto, C., Triglia, T., Pellegrini, L., Ocquidant, P., Bruder, N. J., & Velly, L. J. (2016) · Critical Care · doi:10.1186/s13054-016-1239-z · Cited by 237
Jahns, F.-P., Miroz, J. P., Messerer, M., Daniel, R. T., Taccone, F. S., Eckert, P., & Oddo, M. (2019) · Critical Care · doi:10.1186/s13054-019-2436-3 · Cited by 165
Revision of expert panel's guidelines on postoperative pain management
Aubrun, F., Nouette‐Gaulain, K., Fletcher, D., Belbachir, A., Beloeil, H., Carlès, M., Cuvillon, P., Dadure, C., Lebuffe, G., Marret, E., et al. (2019) · Anaesthesia Critical Care & Pain Medicine · doi:10.1016/j.accpm.2019.02.011 · Cited by 136
Early prediction of coma recovery after cardiac arrest with blinded pupillometry
Solari, D., Rossetti, A. O., Carteron, L., Miroz, J., Nový, J., Eckert, P., & Oddo, M. (2017) · Annals of Neurology · doi:10.1002/ana.24943 · Cited by 110
Riker, R. R., Sawyer, M. E., Fischman, V. G., May, T., Lord, C., Eldridge, A., & Seder, D. B. (2020) · Neurocritical Care · doi:10.1007/s12028-019-00717-4 · Cited by 104
Understanding the Relationship Between the Neurologic Pupil Index and Constriction Velocity Values
Shoyombo, I., Aiyagari, V., Stutzman, S. E., Atem, F., Hill, M., Figueroa, S. A., Miller, C., Howard, A., & Olson, D. M. (2018) · Scientific Reports · doi:10.1038/s41598-018-25477-7 · Cited by 89
Réactualisation de la recommandation sur la douleur postopératoire
Aubrun, F., Gaulain, K. N., Fletcher, D., Belbachir, A., Beloeil, H., Carlès, M., Cuvillon, P., Dadure, C., Lebuffe, G., Marret, E., et al. (2016) · Anesthésie & Réanimation · doi:10.1016/j.anrea.2016.09.006 · Cited by 79
Automated Pupillometry in Neurocritical Care: Research and Practice
Lussier, B. L., Olson, D. M., & Aiyagari, V. (2019) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-019-0994-z · Cited by 79
Pupillometry in perioperative medicine: a narrative review
Packiasabapathy, S., Rangasamy, V., & Sadhasivam, S. (2021) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-020-01905-z · Cited by 76
Non-Invasive Intracranial Pressure Monitoring
Müller, S. J., Henkes, E., Gounis, M. J., Felber, S. R., Ganslandt, O., & Henkes, H. H. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12062209 · Cited by 74
PupilScreen: Using Smartphones to Assess Traumatic Brain Injury
Mariakakis, A. T., Baudin, J., Whitmire, E., Mehta, V., Banks, M. A., Law, A. B., Mcgrath, L., & Patel, S. (2017) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3131896 · Cited by 74
Heimburger, D., Durand, M., Gaide‐Chevronnay, L., Dessertaine, G., Moury, P.-H., Bouzat, P., Albaladejo, P., & Payen, J. (2016) · Resuscitation · doi:10.1016/j.resuscitation.2016.02.026 · Cited by 74
Pain assessment by pupil dilation reflex in response to noxious stimulation in anaesthetized adults
Wildemeersch, D., Peeters, N., Saldien, V., VERCAUTEREN, M. P., & Hans, G. H. (2018) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.13129 · Cited by 74
Shirozu, K., Setoguchi, H., Tokuda, K., Karashima, Y., Ikeda, M., Kubo, M., Nakamura, K., & Hoka, S. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9839-3 · Cited by 72
Intensive Care in Traumatic Brain Injury Including Multi-Modal Monitoring and Neuroprotection
Stocker, R. A. (2019) · Medical Sciences · doi:10.3390/medsci7030037 · Cited by 71
Miroz, J., Ben‐Hamouda, N., Bernini, A., Romagnosi, F., Bongiovanni, F., Roumy, A., Kirsch, M. E. W., Liaudet, L., Eckert, P., & Oddo, M. (2019) · CHEST Journal · doi:10.1016/j.chest.2019.11.037 · Cited by 65
iPhone‐based Pupillometry: A Novel Approach for Assessing the Pupillary Light Reflex
McAnany, J. J., Smith, B. M., Garland, A., & Kagen, S. L. (2018) · Optometry and Vision Science · doi:10.1097/opx.0000000000001289 · Cited by 64
Tamura, T., Namiki, J., Sugawara, Y., Sekine, K., Yo, K., Kanaya, T., Yokobori, S., Roberts, R., Abe, T., Yokota, H., et al. (2018) · Resuscitation · doi:10.1016/j.resuscitation.2018.06.027 · Cited by 64
Pasternak, J. J., & Lanier, W. L. (2009) · Journal of Neurosurgical Anesthesiology · doi:10.1097/ana.0000000000000048 · Cited by 62
Whittaker, A. L., Muns, R., Wang, D., Martínez-Burnes, J., Hernández-Ávalos, I., Casas-Alvarado, A., Domínguez-Oliva, A., & Mota‐Rojas, D. (2023) · Animals · doi:10.3390/ani13132065 · Cited by 62
Correlations Between Hourly Pupillometer Readings and Intracranial Pressure Values
McNett, M., Moran, C., Janki, C., & Gianakis, A. (2017) · Journal of Neuroscience Nursing · doi:10.1097/jnn.0000000000000290 · Cited by 62
Assessing pain in the postoperative period: Analgesia Nociception IndexTM versus pupillometry
Charier, D. J., Vogler, M.-C., Zantour, D., Pichot, V., Martins-Baltar, A., Courbon, M., Roche, F., Vassal, F., & Molliex, S. B. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.09.031 · Cited by 57
Brand, J., Diamond, S. G., Thomas, N., & Gilbert‐Diamond, D. (2020) · Behavior Research Methods · doi:10.3758/s13428-020-01504-2 · Cited by 53
Distributions and Reference Ranges for Automated Pupillometer Values in Neurocritical Care Patients
Lussier, B. L., Stutzman, S. E., Atem, F., Venkatachalam, A. M., Perera, A. C., Barnes, A., Aiyagari, V., & Olson, D. M. (2019) · Journal of Neuroscience Nursing · doi:10.1097/jnn.0000000000000478 · Cited by 52
Role of automated pupillometry in critically ill patients
Morelli, P., Oddo, M., & Ben‐Hamouda, N. (2019) · Minerva Anestesiologica · doi:10.23736/s0375-9393.19.13437-2 · Cited by 50
Kahya, M., Wood, T. A., Sosnoff, J. J., & Devos, H. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00288 · Cited by 49
The Pupillary Light Reflex as a Biomarker of Concussion
Carrick, F. R., Azzolino, S. F., Hunfalvay, M., Pagnacco, G., Oggero, E., D’Arcy, R. C. N., Abdulrahman, M., & Sugaya, K. (2021) · Life · doi:10.3390/life11101104 · Cited by 49
Vinciguerra, L., & Bösel, J. (2016) · Neurocritical Care · doi:10.1007/s12028-016-0361-8 · Cited by 48
Zhang, H., Xu, J., Yang, X., Zou, X., Shu, H., Liu, Z., & Shang, Y. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.713333 · Cited by 48
Natzeder, S., Mack, D. J., Maissen, G., Strässle, C., Keller, E., & Muroi, C. (2018) · Journal of Neurosurgical Anesthesiology · doi:10.1097/ana.0000000000000553 · Cited by 47
Using Pupillary Pain Index to Assess Nociception in Sedated Critically Ill Patients
Vinclair, M., Schilte, C., Roudaud, F., Lavolaine, J., Francony, G., Bouzat, P., Bosson, J.-L., & Payen, J.-F. (2019) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004173 · Cited by 45
Detection of opioid effect with pupillometry
McKay, R. E., & Larson, M. D. (2021) · Autonomic Neuroscience · doi:10.1016/j.autneu.2021.102869 · Cited by 43
Self-citationBaseline Pupil Diameter Is Not a Reliable Biomarker of Subjective Sleepiness
Daguet, I., Bouhassira, D., & Gronfier, C. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00108 · Cited by 43
Digital Pupillometry in Normal Subjects
Rickmann, A., Waizel, M. D. V., Kazerounian, S., Szurman, P., Wilhelm, H. M., & Boden, K. (2016) · Neuro-Ophthalmology · doi:10.1080/01658107.2016.1226345 · Cited by 43
Neurological Pupil Index for the Early Prediction of Outcome in Severe Acute Brain Injury Patients
Romagnosi, F., Bernini, A., Bongiovanni, F., Iaquaniello, C., Miroz, J., Citerio, G., Taccone, F. S., & Oddo, M. (2022) · Brain Sciences · doi:10.3390/brainsci12050609 · Cited by 42
Kim, J., Jwa, E. K., Choung, Y., Yeon, H. J., Kim, S. Y., & Kim, E. (2020) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004958 · Cited by 41
Reshef, E. R., Schiff, N. D., & Brown, E. N. (2019) · Anesthesiology · doi:10.1097/aln.0000000000002559 · Cited by 41
Neurological Pupil Index as an Indicator of Neurological Worsening in Large Hemispheric Strokes
Kim, T. J., Park, S.-H., Jeong, H.-B., Ha, E. J., Cho, W. S., Kang, H.-S., Kim, J. E., & Ko, S.-B. (2020) · Neurocritical Care · doi:10.1007/s12028-020-00936-0 · Cited by 41
Prescott, B. R., Sağlam, H., Duskin, J. A., Miller, M. I., Thakur, A. S., Gholap, E. A., Hutch, M. R., Smirnakis, S. M., Zafar, S. F., Dupuis, J., et al. (2021) · Critical Care Medicine · doi:10.1097/ccm.0000000000005272 · Cited by 40
Favre, E., Bernini, A., Morelli, P., Pasquier, J., Miroz, J., Abed‐Maillard, S., Ben‐Hamouda, N., & Oddo, M. (2020) · Critical Care · doi:10.1186/s13054-020-2796-8 · Cited by 40
Influence of Strategic Cortical Infarctions on Pupillary Function
Peinkhofer, C., Martens, P. C., Grand, J., Truelsen, T. C., Knudsen, G. M., Kjærgaard, J., & Kondziella, D. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00916 · Cited by 40
Sabourdin, N., Diarra, C., Wolk, R., Piat, V., Louvet, N., & Constant, I. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000003681 · Cited by 40
Impact of Increased Intracranial Pressure on Pupillometry: A Replication Study
Al-Obaidi, S. Z., Atem, F., Stutzman, S. E., & Olson, D. M. (2019) · Critical Care Explorations · doi:10.1097/cce.0000000000000054 · Cited by 40
Suppression of pupillary unrest by general anesthesia and propofol sedation
Behrends, M., Larson, M. D., Neice, A. E., & Bokoch, M. P. (2018) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-018-0147-y · Cited by 38
Self-citationGiede-Jeppe, A., Sprügel, M. I., Huttner, H. B., Borutta, M. C., Kuramatsu, J. B., Hoelter, P., Engelhorn, T., Schwab, S., & Koehn, J. (2020) · Neurocritical Care · doi:10.1007/s12028-020-01146-4 · Cited by 37
Assessing Pain Using the Variation Coefficient of Pupillary Diameter
Charier, D. J., Zantour, D., Pichot, V., Chouchou, F., Barthélemy, J., Roche, F., & Molliex, S. B. (2017) · Journal of Pain · doi:10.1016/j.jpain.2017.06.006 · Cited by 37
Boulter, J. H., Shields, M. M., Meister, M. R., Murtha, G., Curry, B. P., & Dengler, B. A. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.685313 · Cited by 36
Petrosino, M., Bogossian, E. G., Rebora, P., Galimberti, S., Chesnut, R. M., Bouzat, P., Oddo, M., Taccone, F. S., Citerio, G., & ORANGE Participants and Investigators (2024) · JAMA Neurology · doi:10.1001/jamaneurol.2024.4189 · Cited by 35
Prognostic value of automated pupillometry: an unselected cohort from a cardiac intensive care unit
Obling, L. E. R., Hassager, C., Illum, C., Grand, J., Wiberg, S. C., Lindholm, M. G., Winther‐Jensen, M., Kondziella, D., & Kjærgaard, J. (2020) · European Heart Journal Acute Cardiovascular Care · doi:10.1177/2048872619842004 · Cited by 34
Application of Pupillometry in Neurocritical Patients
Hsu, C.-H., & Kuo, L. (2023) · Journal of Personalized Medicine · doi:10.3390/jpm13071100 · Cited by 33
Tamura, T., Namiki, J., Sugawara, Y., Sekine, K., Yo, K., Kanaya, T., Yokobori, S., Abe, T., Yokota, H., & Sasaki, J. (2020) · PLoS ONE · doi:10.1371/journal.pone.0228224 · Cited by 32
Pain sensing neurons promote tissue regeneration in adult mice
Rabiller, L., Labit, E., Guissard, C., Gilardi, S., Guiard, B. P., Moulédous, L., Silva, M., Mithieux, G., Pénicaud, L., Lorsignol, A., et al. (2021) · npj Regenerative Medicine · doi:10.1038/s41536-021-00175-7 · Cited by 32
At-Home Pupillometry using Smartphone Facial Identification Cameras
Barry, C., de Souza, J., Xuan, Y., Holden, J. L., Granholm, E. L., & Wang, E. J. (2022) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3491102.3502493 · Cited by 32
Vassilieva, A., Olsen, M. H., Peinkhofer, C., Knudsen, G. M., & Kondziella, D. (2019) · PeerJ · doi:10.7717/peerj.6929 · Cited by 31
Anderson, T. A., Segaran, J., Toda, C., Sabouri, A. S., & Jonckheere, J. D. (2019) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004180 · Cited by 31
Stavern, G. P. V., Bei, L., Shui, Y., Huecker, J. B., & Gordon, M. E. (2018) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-312425 · Cited by 30
Infrared pupillometry helps to detect and predict delirium in the post-anesthesia care unit
Yang, E., Kreuzer, M., Hesse, S., Davari, P., Lee, S. C., & García, P. S. (2017) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-017-0009-z · Cited by 30
Neuroprognostication after cardiac arrest in the light of targeted temperature management
Oddo, M., & Friberg, H. (2017) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000406 · Cited by 29
Monitoring the Brain After Cardiac Arrest: a New Era
Sinha, N., & Parnia, S. (2017) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-017-0770-x · Cited by 27
Shi, L., Zheng, L., Jin, D., Lin, Z., Zhang, Q., & Zhang, M. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.828428 · Cited by 27
Early Pupillometry Assessment in Traumatic Brain Injury Patients: A Retrospective Study
Teixeira, T. L., Peluso, L., Banco, P., Njimi, H., Abi-Khalil, L., Pillajo, M. C., Schuind, S., Créteur, J., Bouzat, P., & Taccone, F. S. (2021) · Brain Sciences · doi:10.3390/brainsci11121657 · Cited by 26
Oddo, M., Taccone, F. S., Galimberti, S., Rebora, P., & Citerio, G. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-046948 · Cited by 26
Use of Digital Pupillometry to Measure Sedative Response to Propofol.
Haddock, J. L., Mercante, D. E., Paccione, R., Breaux, J., Jolley, S. E., Johnson, J. L., Connolly, S. E., & deBoisblanc, B. P. (2017) · Europe PMC (PubMed Central) · Cited by 26
Bellavia, S., Scala, I., Luigetti, M., Brunetti, V., Gabrielli, M., Verme, L. Z. D., Servidei, S., Calabresi, P., Frisullo, G., & Marca, G. D. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10245861 · Cited by 25
The Role of Automated Infrared Pupillometry in Traumatic Brain Injury: A Narrative Review
Vrettou, C. S., Fragkou, P. C., Mallios, I., Barba, C., Giannopoulos, C., Gavrielatou, E., & Dimopoulou, I. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13020614 · Cited by 25
Obinata, H., Yokobori, S., Shibata, Y., Takiguchi, T., Nakae, R., Igarashi, Y., Shigeta, K., Matsumoto, H., Aiyagari, V., Olson, D. M., et al. (2020) · Resuscitation · doi:10.1016/j.resuscitation.2020.06.002 · Cited by 25
Portable infrared pupillometry in critical care
Larson, M. D., & Singh, V. (2016) · Critical Care · doi:10.1186/s13054-016-1349-7 · Cited by 25
Self-citationSabourdin, N., Meniolle, F., Chemam, S., Rigouzzo, A., Hamza, J., Louvet, N., & Constant, I. (2019) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004362 · Cited by 25
Oddo, M., Bracard, S., Cariou, A., Chanques, G., Citerio, G., Clerckx, B., Godeau, B., Godiér, A., Horn, J., Jaber, S., et al. (2019) · Annals of Intensive Care · doi:10.1186/s13613-019-0523-x · Cited by 24
The use and uptake of pupillometers in the Intensive Care Unit
Lee, M. H., Mitra, B., Pui, J. K., & Fitzgerald, M. (2017) · Australian Critical Care · doi:10.1016/j.aucc.2017.06.003 · Cited by 24
Dexmedetomidine and Other Analgosedatives Alter Pupil Characteristics in Critically Ill Patients
Chan, W. P., Prescott, B. R., Barra, M. E., Chung, D. Y., Kim, I. S. Y., Sağlam, H., Hutch, M. R., Shin, M. C., Zafar, S. F., Benjamin, E. J., et al. (2022) · Critical Care Explorations · doi:10.1097/cce.0000000000000691 · Cited by 23
Mobile Smartphone-Based Digital Pupillometry Curves in the Diagnosis of Traumatic Brain Injury
McGrath, L. B., Eaton, J. C., Abecassis, I. J., Maxin, A. J., Kelly, C. M., Chesnut, R. M., & Levitt, M. R. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.893711 · Cited by 23
Pupillary dilation reflex and behavioural pain scale: Study of diagnostic test
de Aberasturi, Y. L. D. A.-J., de la Cueva, A. V., Cortajarena, N. A., Quintano-Rodero, A., Núñez, C. R., Pelegrin-Gaspar, P. M., Garcia, Z. I. G., Margüello-Fernandez, A. A., Cilla, L. A., & Parraza, N. (2022) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2022.103332 · Cited by 22
Comparison of 2 Automated Pupillometry Devices in Critically III Patients
Robba, C., Salihovic, B. M., Pozzebon, S., Créteur, J., Oddo, M., Vincent, J., & Taccone, F. S. (2019) · Journal of Neurosurgical Anesthesiology · doi:10.1097/ana.0000000000000604 · Cited by 21
Ghezzi, M. D., Ceriani, M. C., Domínguez-Oliva, A., Lendez, P. A., Olmos-Hernández, A. S., Casas-Alvarado, A., & Hernández-Ávalos, I. (2024) · Animals · doi:10.3390/ani14091366 · Cited by 21
Wang, C., Wu, C., Liu, C. C.-Y., Hsu, T.-C., Liu, M. A., Wu, M., Tsai, M., Chang, W., Huang, C., Lee, C., et al. (2021) · Critical Care Medicine · doi:10.1097/ccm.0000000000005045 · Cited by 20
Relationship Between the Onset of Ménière's Disease and Sympathetic Hyperactivity
Ishii, M., Ishiyama, G. P., Ishiyama, A., Kato, Y., Mochizuki, F., & Ito, Y. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.804777 · Cited by 20
Quantitative pupillometry and radiographic markers of intracranial midline shift: A pilot study
Kim, I. S. Y., Balogun, O. O., Prescott, B. R., Sağlam, H., Olson, D. M., Speir, K., Stutzman, S. E., Schneider, N., Aguilera, V., Lussier, B. L., et al. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.1046548 · Cited by 20
Pilot Study of Smartphone Infrared Pupillography and Pupillometry
Solyman, O. M., Abushanab, M. M. I., Carey, A. R., & Henderson, A. D. (2022) · Clinical ophthalmology · doi:10.2147/opth.s331989 · Cited by 20
The melanopsin-mediated pupil response is reduced in idiopathic hypersomnia with long sleep time
Rach, H., Kilic-Huck, Ü., Reynaud, È., Hugueny, L., Peiffer, É., Belleplaine, V. R. D., Fuchs, F., Bourgin, P., & Geoffroy, P. A. (2022) · Scientific Reports · doi:10.1038/s41598-022-13041-3 · Cited by 18
Space neuroscience: current understanding and future research
Shirah, B. H., Ibrahim, B. M., Aladdin, Y. S., & Sen, J. (2022) · Neurological Sciences · doi:10.1007/s10072-022-06146-0 · Cited by 18
Vide, S., Castro, A., Correia, R., Cabral, T., Lima, D., Nunes, C. S., Gambús, P. L., & Amorim, P. (2020) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-020-00570-3 · Cited by 18
Huyghe, T., Calleja-González, J., Bird, S. P., & Alcaráz, P. E. (2023) · Biology of Sport · doi:10.5114/biolsport.2024.125590 · Cited by 17
Feasibility study of a smartphone pupillometer and evaluation of its accuracy
Neice, A. E., Fowler, C., Jaffe, R., & Brock‐Utne, J. G. (2020) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-020-00592-x · Cited by 17
Eyeing up the injured brain: automated pupillometry and optic nerve sheath diameter
Romagnosi, F., Bongiovanni, F., & Oddo, M. (2020) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000710 · Cited by 17
Quantitative assessments of pupillary light reflexes in neurocritically ill patients
Kim, T. J. (2022) · Journal of Neurocritical Care · doi:10.18700/jnc.220085 · Cited by 16
Shao, L., Zhou, Y., Yue, Z., Gu, Z., Zhang, J., Hui, K., Xiong, J., Xu, M., & Duan, M. (2022) · BMC Anesthesiology · doi:10.1186/s12871-022-01808-0 · Cited by 15
Suo, L., Zhang, D., Qin, X., Li, A., Zhang, C., & Wang, Y. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00777 · Cited by 15
Adequacy of Anesthesia and Pupillometry for Endoscopic Sinus Surgery
Stasiowski, M. J., Szumera, I., Wardas, P., Król, S., Żak, J., Missir, A., Pluta, A., Niewiadomska, E., Krawczyk, L., Jałowiecki, P., et al. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10204683 · Cited by 15
Measuring the Pupillary Light Reflex Using Portable Instruments in Applied Settings
Gray, N. S., Price, M. J., Pink, J. C., O’Connor, C., Antunes, A., & Snowden, R. J. (2024) · Vision · doi:10.3390/vision8040060 · Cited by 14
Vide, S., Kreuzer, M., Ferreira, A., Couto, M., Agustí, M., Jaramillo, S., Schneider, G. H., García, P. S., Abelha, F., Amorim, P., et al. (2025) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2025.111825 · Cited by 14
Self-citationWarren, A., McCarthy, C., Andiapen, M., Crouch, M., Finney, S. J., Hamilton, S., Jain, A. K., Jones, D. A., & Proudfoot, A. G. (2022) · British Journal of Anaesthesia · doi:10.1016/j.bja.2021.12.052 · Cited by 14
Smartphone Based Pupillometry: An Empirical Evaluation of Accuracy and Safety
Calandra, D. M., Martino, S. D., Riccio, D., & Visconti, A. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-68548-9_40 · Cited by 13
Kirk, C., & Childs, C. (2023) · Vision · doi:10.3390/vision7020039 · Cited by 13
Barak-Dror, O. B., Hadad, B., Barhum, H., Haggiag, D., Tepper, M., Gannot, I., & Nir, Y. (2024) · Communications Medicine · doi:10.1038/s43856-024-00572-1 · Cited by 13
Grandin, T., Velarde, A., Strappini, A. C., Gerritzen, M. A., Ghezzi, M. D., Martínez-Burnes, J., Hernández-Ávalos, I., Domínguez-Oliva, A., Casas-Alvarado, A., & Mota‐Rojas, D. (2023) · Animals · doi:10.3390/ani13152406 · Cited by 13
Metadata
- Authors
- Larson, M. D., & Behrends, M.
- Venue
- Anesthesia & Analgesia
- Published
- 2015-06
- Volume
- 120
- Issue
- 6
- Pages
- 1242-1253
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2336988105
- Cited by
- 242
- References
- 106
- FWCI
- 18.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.