Portable Infrared Pupillometry: A Review
The DOI matches its Crossref record; 106 of the 106 references it cites were found in a registry or an index.
Abstract
Portable infrared pupillometers provide an objective measure of pupil size and pupillary reflexes, which for most clinicians was previously only a visual impression. But despite the fact that pupillometry can uncover aspects of how the human pupil reacts to drugs and noxious stimulation, the use of pupillometry has not gained widespread use among anesthesiologists and critical care physicians. The present review is an introduction to the physiology of pupillary reflexes and the currently established clinical applications of infrared pupillometry, which will hopefully encourage physicians to use this diagnostic tool in their clinical practice. Portable infrared pupillometry was introduced in 1989. The technology involves flooding the eye with infrared light and then measuring the reflected image on an infrared sensor. Pupil size, along with variables of the pupillary light reflex and pupillary reflex dilation, is calculated by the instrument and displayed on a screen immediately after each time-stamped measurement. Use of these instruments has uncovered aspects of how the human pupil reacts to drugs and noxious stimulation. The primary clinical applications for portable pupillometry have been in the assessment of brainstem function. Portable pupillometry is useful in the management of pain because it allows for assessments of the effect of opioids and in the titration of combined regional-general anesthetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These systems can analyze changes in pupil diameter at the millisecond level and evaluate multiple parameters, such as maximum and minimum pupil diameter, constriction and dilation velocities, latency, and symmetry, using standardized protocols (8,29).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [29]
In the citing paper
“Nevertheless, the high cost of devices and their limited availability across clinical settings remain major factors restricting the widespread use of quantitative pupillometry (29,38).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [29]
In the citing paper
“In recent years, pupillometric parameters such as the Pupillary Pain Index (PPI) and constriction velocity/latency have been reported as reliable indicators that assist in ensuring intraoperative and postoperative analgesia and in assessing pain severity (29,37,(49)(50)(51).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [29]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aston-Jones, G., & Cohen, J. D. (2005) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.28.061604.135709 · Cited by 4,472
Codeine Intoxication Associated with Ultrarapid CYP2D6 Metabolism
Gasche, Y., Daali, Y., Fathi, M., Chiappe, A., Cottini, S., Dayer, P., & Desmeules, J. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041888 · Cited by 702
Physiology and Pathophysiology of the Human Sympathoadrenal Neuroendocrine System
Bleich, H. L., Moore, M. J., & Cryer, P. E. (1980) · New England Journal of Medicine · doi:10.1056/nejm198008213030806 · Cited by 652
Human and macaque pupil responses driven by melanopsin-containing retinal ganglion cells
Gamlin, P. D. R., McDougal, D. H., Pokorny, J., Smith, V. C., Yau, K.-W., & Dacey, D. M. (2007) · Vision Research · doi:10.1016/j.visres.2006.12.015 · Cited by 617
How opioids inhibit GABA-mediated neurotransmission
Vaughan, C. W., Ingram, S. L., Connor, M. A., & Christie, M. J. (1997) · Nature · doi:10.1038/37610 · Cited by 507
Predicting the Outcome From Hypoxic-Ischemic Coma
Jorgensen, E. O. (1986) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1986.03370120043011 · Cited by 494
Predicting Outcome From Hypoxic-lschemic Coma
Levy, D. E. (1985) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1985.03350340072020 · Cited by 432
A unified formula for light-adapted pupil size
Watson, A. B., & Yellott, J. I. (2012) · Journal of Vision · doi:10.1167/12.10.12 · Cited by 399
Chen, J., Gombart, Z., Rogers, S., Gardiner, S., Cecil, S., & Bullock, R. (2011) · Surgical Neurology International · doi:10.4103/2152-7806.82248 · Cited by 314
Melanopsin signalling in mammalian iris and retina
Xue, T., Do, M. T. H., Riccio, A., Jiang, Z., Hsieh, J., Wang, H. C., Merbs, S. L., Welsbie, D. S., Yoshioka, T., Weissgerber, P., et al. (2011) · Nature · doi:10.1038/nature10567 · Cited by 303
Cited by
Items 101–200 of 279
Dynamic assessment of the pupillary reflex in patients on high-dose opioids
Kongsgaard, U. E., & Høiseth, G. (2019) · Scandinavian Journal of Pain · doi:10.1515/sjpain-2019-0032 · Cited by 13
Development of reference intervals for pupillometry in healthy dogs
Mills, E. P., Combs-Ramey, K., Kwong, G. P. S., & Pang, D. (2022) · Frontiers in Veterinary Science · doi:10.3389/fvets.2022.1020710 · Cited by 12
Pupillometry as a method for monitoring of pupillary light reflex in ICU patients
Av, O., Alexandrova, E. V., Muradyan, K. R., Sosnovskaya, O. Y., Sokolova, E. Y., & Савин, И. А. (2021) · Burdenko s Journal of Neurosurgery · doi:10.17116/neiro202185031117 · Cited by 12
Themas, K., Zisis, M., Kourek, C., Konstantinou, G., D’Anna, L., Papanagiotou, P., Ntaios, G., Dimopoulos, S. K., & Korompoki, E. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13196014 · Cited by 12
Pharmacodynamic modelling of the effect of remifentanil using the Pupillary Pain Index
Vide, S., Castro, A., Antunes, P., Lima, D., Larson, M. D., Gambús, P. L., & Amorim, P. (2019) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00323-x · Cited by 12
Self-citationVlaenderen, D. V., Hans, G. H., Saldien, V., & Wildemeersch, D. (2022) · Pain Management · doi:10.2217/pmt-2022-0027 · Cited by 12
(2018) · Romanian Journal of Anaesthesia and Intensive Care · doi:10.21454/rjaic.7518.251.wil · Cited by 11
Mendes, F. C., Paciência, I., Rufo, J. C., Farraia, M., Silva, D., Padrão, P., Delgado, L., García-Larsen, V., Moreira, A. M., & Moreira, P. A. M. (2021) · Nutrients · doi:10.3390/nu13051456 · Cited by 11
Pupil Size Prediction Techniques Based on Convolution Neural Network
Whang, A. J.-W., Chen, Y., Tseng, W.-C., Tsai, C.-H., Chao, Y., Yen, C.-H., Liu, C.-H., & Zhang, X. (2021) · Sensors · doi:10.3390/s21154965 · Cited by 11
Investigating the association between eye colour and the Neurological Pupil index
Al-Obaidi, S., Atem, F., Stutzman, S. E., Aiyagari, V., & Olson, D. M. (2020) · Australian Critical Care · doi:10.1016/j.aucc.2019.10.001 · Cited by 11
Progress in the validation of nociception monitoring in guiding intraoperative analgesic therapy
Santvliet, H. V., & Vereecke, H. E. M. (2024) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000001390 · Cited by 11
Effects of Ketamine on Pupillary Reflex Dilation: A Case Report
Vide, S., Costa, C. M., Gambús, P. L., & Amorim, P. (2017) · A&A Practice · doi:10.1213/xaa.0000000000000633 · Cited by 10
The Pupillary Light-Off Reflex in Acute Disorders of Consciousness
Zarifkar, P., Othman, M., Hansen, K. I. T., Amiri, M., Stückler, S. G., Fabritius, M. L., Sigurðsson, S. Þ., Hassager, C., Birkeland, P., Hauerberg, J., et al. (2024) · Neurocritical Care · doi:10.1007/s12028-024-02133-9 · Cited by 10
Self-citationStasiowski, M. J., Zmarzły, N., Grabarek, B. O., & Gąsiorek, J. (2023) · Pharmaceuticals · doi:10.3390/ph17010002 · Cited by 10
Objective Assessment of Acute Pain
Laycock, H. C., & Bantel, C. (2016) · Journal of Anesthesia & Clinical Research · doi:10.4172/2155-6148.1000630 · Cited by 9
Through the looking glass: early non-invasive imaging in TBI predicts the need for interventions
Glaser, J., Vasquez, M., Cardarelli, C. L., Galvagno, S. M., Stein, D. M., Murthi, S. B., & Scalea, T. M. (2016) · Trauma Surgery & Acute Care Open · doi:10.1136/tsaco-2016-000019 · Cited by 9
Veerapaneni, D., Sakthiyendran, N. A., Du, Y., Mallinger, L. A., Reinert, A., Kim, S. Y., Nguyen, C., Daneshmand, A., Abdalkader, M. K., Mohammed, S., et al. (2025) · Critical Care Explorations · doi:10.1097/cce.0000000000001257 · Cited by 9
Favre, E., Rahmaty, Z., Ben‐Hamouda, N., Miroz, J., Abed‐Maillard, S., Rusca, M., Oddo, M., & Ramelet, A. (2023) · Australian Critical Care · doi:10.1016/j.aucc.2023.07.038 · Cited by 9
Assessing brain injury after cardiac arrest, towards a quantitative approach
Cronberg, T. (2019) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000611 · Cited by 9
Packiasabapathy, S., Zhang, X., Ding, L., Aruldhas, B. W., Pawale, D., & Sadhasivam, S. (2021) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000005579 · Cited by 8
Opening a Window to the Injured Brain: Non-invasive Neuromonitoring with Quantitative Pupillometry
Solari, D., Miroz, J., & Oddo, M. (2018) · Annual update in intensive care and emergency medicine · doi:10.1007/978-3-319-73670-9_38 · Cited by 8
Kim, J. G., Shin, H., Lim, T. H., Kim, W., Cho, Y., Jang, B.-H., Choi, K.-S., Na, M. K., Ahn, C., & Lee, J. (2022) · Medicina · doi:10.3390/medicina58060804 · Cited by 8
Lee, S., Jung, D.-E., Park, D., Kim, T. J., Lee, H., Bae, J., Nam, K., Jeon, Y., & Cho, Y. J. (2023) · Scientific Reports · doi:10.1038/s41598-023-41151-z · Cited by 8
Nersesjan, V., Martens, P. C., Truelsen, T. C., & Kondziella, D. (2020) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2020.117145 · Cited by 8
Pouzot‐Nevoret, C., Junot, S., Goffette, L., Bonnet‐Garin, J., Allaouchiche, B., & Magnin, M. (2023) · Research in Veterinary Science · doi:10.1016/j.rvsc.2023.03.014 · Cited by 7
Opioid Effects and Classification
Cruz, S. L., Paz-Ramos, M. I., Hernández-Mendoza, A., & Carranza‐Aguilar, C. J. (2022) · Springer eBooks · doi:10.1007/978-3-031-09936-6_8 · Cited by 7
Chronic Disorders of Consciousness
Kothari, S. (2018) · Springer eBooks · doi:10.1007/978-3-319-93215-6_4 · Cited by 7
Casey, F., Van, H. M. T., Donovan, J., Nghia, H. D. T., Oanh, P. K. N., Thwaites, L., Phu, N. H., & Thwaites, G. E. (2023) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2023.120808 · Cited by 7
Prognosis value of pupillometry in COVID-19 patients admitted in intensive care unit
Daniel, M., Charier, D. J., Pereira, B., Pachcinski, M., Sharshar, T., & Molliex, S. B. (2022) · Autonomic Neuroscience · doi:10.1016/j.autneu.2022.103057 · Cited by 7
Himmel, H. M., & Faelker, T. M. E. (2019) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2019.106588 · Cited by 7
Automated pupillometry in space neuroscience
Shirah, B. H., Sen, J., Naaman, N. K., & Pandya, S. (2023) · Life Sciences in Space Research · doi:10.1016/j.lssr.2023.01.004 · Cited by 7
Kornilov, E., Gehlen, L., Yacobi, D., Soehle, M., Kowark, A., & Thudium, M. O. (2023) · Medicina · doi:10.3390/medicina59050826 · Cited by 7
Camilo, E. N. R., Paranhos, A., Pinheiro, H. M., & da Costa, R. M. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.109594 · Cited by 6
Marco‐Ariño, N., Vide, S., Agustí, M., Chen, A. L., Jaramillo, S., Irurzun‐Arana, I., Pacheco, A., González, C., Jensen, E. W., Capsi‐Morales, P., et al. (2021) · CPT Pharmacometrics & Systems Pharmacology · doi:10.1002/psp4.12729 · Cited by 6
Self-citationInterdevice Agreement between a Smartphone and a Commercial Pupillometer
Rattan, Y., Girgla, K. K., Mahajan, G., & Prasher, P. (2024) · International Journal of Applied and Basic Medical Research · doi:10.4103/ijabmr.ijabmr_396_23 · Cited by 6
Réactualisation de la recommandation sur la douleur postopératoire
Aubrun, F., Gaulain, K. N., Fletcher, D., Belbachir, A., Beloeil, H., Carlès, M., Cuvillon, P., Dadure, C., Lebuffe, G., Marret, E., et al. (2017) · Douleurs Évaluation - Diagnostic - Traitement · doi:10.1016/j.douler.2017.01.007 · Cited by 6
Noda, K., Tanaka, T., Abe, S., Usui, R., Matsumoto, M., Arakaki, Y., Kida, H., Inui, R., Kohama, K., Washida, K., et al. (2024) · Journal of Stroke · doi:10.5853/jos.2023.04406 · Cited by 6
Scala, I., Miccoli, M., Pafundi, P. C., Rizzo, P. A., Vitali, F., Bellavia, S., Giovanni, J. D., Colò, F., Marca, G. D., Guglielmi, V., et al. (2024) · Brain Sciences · doi:10.3390/brainsci14060616 · Cited by 6
Pupillometry to show stress release during equine sports massage therapy
Wild, K. N., Skiba, S., Räsänen, S., & Richter, C. (2023) · Scientific Reports · doi:10.1038/s41598-023-47590-y · Cited by 6
Kossel, C.-S., Kobus, F., Borutta, M. C., Kaertner, M., Kuramatsu, J. B., Engelhorn, T., Schwab, S., & Koehn, J. (2023) · Journal of Neurology · doi:10.1007/s00415-023-11797-w · Cited by 6
Tran, D. K., Poole, C., Tobias, E., Moores, L., Espinoza, M., & Chen, J. W. (2022) · World Neurosurgery · doi:10.1016/j.wneu.2022.01.022 · Cited by 6
Paradoxical Contralateral Herniation Detected by Pupillometry in Acute Syndrome of the Trephined
Fischer, V. E., Boulter, J. H., Bell, R. S., & Ikeda, D. S. (2020) · Military Medicine · doi:10.1093/milmed/usz409 · Cited by 6
Cody, P. A., Kumar, M., & Tzounopoulos, T. (2024) · Journal of Neuroscience · doi:10.1523/jneurosci.0939-23.2024 · Cited by 5
The Neurological Exam of a Comatose Patient: An Essential Practical Guide
Zakaria, Z., Abdullah, M. M., Halim, S. A., Ghani, A. R. I., Idris, Z., & Abdullah, J. M. (2020) · Malaysian Journal of Medical Sciences · doi:10.21315/mjms2020.27.5.11 · Cited by 5
Roquet, F., Guezouli, L., Wachowska, B., Balcan, I., Montravers, P., Longrois, D., & Guglielminotti, J. R. (2017) · Anaesthesia Critical Care & Pain Medicine · doi:10.1016/j.accpm.2017.06.007 · Cited by 5
Fang, P., Wu, J., Tang, L., Gao, S., & Liu, X. (2021) · Pain Practice · doi:10.1111/papr.13084 · Cited by 5
Pupillometric findings in ATTRv patients and carriers: results from a single-centre experience
Romano, Â., Guglielmino, V., Paolantonio, A. D., Bisogni, G., Sabatelli, M., Marca, G. D., Minnella, A. M., Maceroni, M., Bellavia, S., Scala, I., et al. (2022) · Amyloid · doi:10.1080/13506129.2022.2117601 · Cited by 5
Quantitative intraoperative monitoring of analgesia
Tarasova, N., Shmigelsky, A. V., Lubnin, А. Y., & Kulikov, A. S. (2020) · Russian Journal of Anesthesiology and Reanimatology · doi:10.17116/anaesthesiology202003127 · Cited by 5
A Study of Pupil Response to Light as a Digital Biomarker of Recent Cannabis Use
Godbole, S. V., Leroux, A., Brooks‐Russell, A., Subramanian, P. S., Kosnett, M. J., & Wrobel, J. (2024) · Digital Biomarkers · doi:10.1159/000538561 · Cited by 5
Huang, H., Qiu, Y., Gu, G., Mei, X., Pang, L., Zhang, C., Ran, M., & Li, M. (2024) · BMC Anesthesiology · doi:10.1186/s12871-024-02428-6 · Cited by 5
Pupil response to painful stimuli during inhalation anaesthesia without opioids in children
Ji, S., Cho, S., Jang, Y., Kim, E., Lee, J., Kim, J., & Kim, H. (2022) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.14071 · Cited by 5
BIE-PInCS: Brain injury evaluation with pupillometer based on infrared camera system
Bracco, F., Vece, C. D., Cerina, L., & Santambrogio, M. D. (2017) · IEEE International Forum on Research and Technology for Society and Industry (RTSI) · doi:10.1109/rtsi.2017.8065976 · Cited by 5
Ong, C. J. (2020) · CHEST Journal · doi:10.1016/j.chest.2020.01.001 · Cited by 4
Mariani, S., Piero, M. E. D., & Haverich, A. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-18918-0.00005-x · Cited by 4
A Pilot Study of Automated Pupillometry in the Treatment of Opioid Use Disorder
Peeler, C. E., Gorgy, M., Sadlak, N., Sathe, S., Tamashunas, N. L., Fiorello, M. G., Cabral, H., Paasche‐Orlow, M. K., & Weinstein, Z. (2020) · Journal of Addiction Medicine · doi:10.1097/adm.0000000000000794 · Cited by 4
Kim, S. Y., Kim, J., Kim, J., Yu, S., Lee, K. H., Lee, H. S., Oh, M. S., & Kim, E. (2022) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000006079 · Cited by 4
Compact High-Resolution Multi-Wavelength LED Light Source for Eye Stimulation
Gibertoni, G., Borghi, G., & Rovati, L. L. (2024) · Electronics · doi:10.3390/electronics13061127 · Cited by 4
Jurth, C., Zimmermann, V., Schaaf, L., Lezius, F., Bublitz, V., Lichtner, G., & von Dincklage, F. (2022) · European Journal of Pain · doi:10.1002/ejp.2019 · Cited by 4
The Pupil: Behavior, Anatomy, Physiology and Clinical Biomarkers
Zele, A. J., & Gamlin, P. D. R. (2020) · Frontiers research topics · doi:10.3389/978-2-88963-756-0 · Cited by 4
Steinhart, B., Brooks‐Russell, A., Kosnett, M. J., Subramanian, P. S., & Wrobel, J. (2023) · Journal of Data Science · doi:10.6339/23-jds1103 · Cited by 4
Liu, H., Xing, L.-J., Xie, H., Zhou, X., & Zhu, J. (2025) · Medical Science Monitor · doi:10.12659/msm.948209 · Cited by 4
Singh, A., Akhileshwar, Kumar, N., De, R. R., Bahadur, R., & Shekhar, S. (2023) · Cureus · doi:10.7759/cureus.43894 · Cited by 4
Behrends, M., & Larson, M. D. (2024) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-024-02716-2 · Cited by 4
Self-citationAssessing bedside measures of autonomic nervous system dysregulation in the PICU
Badke, C. M., Carroll, M. S., Pendergrast, T. R., Weese‐Mayer, D. E., & Sanchez-Pinto, L. N. (2025) · Pediatric Research · doi:10.1038/s41390-024-03778-0 · Cited by 4
Analgesia: Effects on Response to Nociceptive Stimulation
Boselli, E., & Jeanne, M. (2019) · Cambridge University Press eBooks · doi:10.1017/9781316443217.008 · Cited by 4
The Photomotor Response - Dynamic Quantification by a Portable Pupillometer
Rosen, J., Privitera, C. M., Bulmus, R., Nakamura, M., & Hartmann, A. (2020) · American Journal of Internal Medicine · doi:10.11648/j.ajim.20200805.17 · Cited by 3
SmartPLR: a digital solution for AI-powered smartphone pupillometry
Kim, K., Kim, D. K., Lee, J. H., & Kim, Y. C. (2025) · BMC Ophthalmology · doi:10.1186/s12886-025-04462-5 · Cited by 3
Yu, L., Yang, Y., Wu, H., Yu, Y., Wang, Y., Yan, S., Li, N., Li, H., Chen, C., & Zhang, Z. (2023) · Minerva Anestesiologica · doi:10.23736/s0375-9393.23.17303-2 · Cited by 3
Charier, D. J. (2019) · theses.fr (ABES) · doi:10.70675/9314c0ffz707fz455az8217za286abceaa46 · Cited by 3
Malewicz, N. M., Skorupka, N., Bartholmes, F., Dombrowski, A., Ebel, M., Zahn, P. K., & Meyer‐Frießem, C. H. (2025) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000002143 · Cited by 3
The Influence of Opioids on Pupil Initial Diameter and Pupillary Dilation Velocity in ICU Patients
Sørensen, V. O. I., Uhrenholt, S., Stokholm, J., Christensen, T., & Bestle, M. H. (2025) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.70080 · Cited by 3
Vrijdag, X. C. E., Deep Dive Dubai, D., van Waart, H., SLEIGH, J. W., & Mitchell, S. J. (2020) · Diving and Hyperbaric Medicine Journal · doi:10.28920/dhm50.2.115-120 · Cited by 3
Konno, M., Niwa, H., Kitayama, M., & Hirota, K. (2024) · Journal of Anesthesia · doi:10.1007/s00540-023-03297-y · Cited by 3
Monitoring the depth of palliative sedation by video-pupillometry: A case report
Elyn, A., Saffon, N., & Larson, M. D. (2021) · Palliative Medicine · doi:10.1177/02692163211042770 · Cited by 3
Self-citationVinclair, M., Roudaud, F., Francony, G., & Payen, J. (2017) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000548 · Cited by 3
Foster, M. (2017) · Cited by 2
Effects of buprenorphine buccal film and oral oxycodone on pupil diameter in a respiratory study
Webster, L. R., Cater, J. R., & Thomas Smith, M. (2022) · Journal of Opioid Management · doi:10.5055/jom.2022.0708 · Cited by 2
Kothari, S., Gilbert-Baffoe, E., & O’Brien, K. A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-323-54456-6.00014-1 · Cited by 2
González, M. G., García, I. A., Soto-Goñi, X., & Jiménez‐Ortega, L. (2024) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2024.09.009 · Cited by 2
Savvina, I. A., Рыжкова, Д. В., Bykova, K. M., Lebedev, K. E., Petrova, A. O., Dryagina, N. V., Геннадьевна, П. Е., & Nazaralieva, E. T. (2024) · IntechOpen eBooks · doi:10.5772/intechopen.108392 · Cited by 2
Bouzat, P., Blandino-Ortiz, A., Vilotitch, A., Pollet, A., Zorzi, S., Vathi, S., Polato, M., Gauss, T., & Taccone, F. S. (2026) · Critical Care · doi:10.1186/s13054-026-06360-8 · Cited by 2
Determining brain states with pupil size and eye movements in sleeping mice and humans
Yüzgeç, Ö. (2020) · Archive ouverte UNIGE (University of Geneva) · doi:10.13097/archive-ouverte/unige:146946 · Cited by 2
Métodos não invasivos para monitorização da pressão intracraniana: uma revisão atual
Mussi, H. G., Rezende, B. E. S., Caciquinho, I. B., Félix, L. C. S., Pessoa, L. D. S. G., Weinem, M. C. F., Cerceau, M. P. B., Santos, J. P. R., de Queiroz, J. G. V., & Reis, B. L. (2023) · Revista Eletrônica Acervo Saúde · doi:10.25248/reas.e11450.2023 · Cited by 2
Effect of nose twitching on the pupillary dilation in awake and anesthetized horses
Triedo, C. M., Karar, S., Abunemeh, M., & Portier, K. (2024) · Frontiers in Veterinary Science · doi:10.3389/fvets.2024.1412755 · Cited by 2
de Aberasturi, Y. L. D. A.-J., de la Cueva, A. V., Ampudia, C. B., Francisco, I. P., Ibarrondo, M. B., & Parraza, N. (2025) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2025.103975 · Cited by 2
Richman, J. E. (2017) · Advances in Ophthalmology and Optometry · doi:10.1016/j.yaoo.2017.03.002 · Cited by 2
Portable Infrared Pupillometry: Ready for Prime Time?
Rosow, C. E. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000724 · Cited by 2
Pupil and Pupillary Light Reflex
Özdağ, D., & Oztas, B. (2025) · Sakarya Üniversitesi Holistik Sağlık Dergisi · doi:10.54803/sauhsd.1767753 · Cited by 1
Daguet, I., Raverot, V., & Gronfier, C. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.02.05.578180 · Cited by 1
Колесников, А. Н. (2025) · Military and tactical medicine Emergency medicine · doi:10.55359/2782-3296.2025.19.4.013 · Cited by 1
Teixeira, B. G., Paciência, I., Rufo, J. C., Mendes, F. C., Farraia, M., Padrão, P., Moreira, P. A. M., & Moreira, A. M. (2023) · Acta Médica Portuguesa · doi:10.20344/amp.17144 · Cited by 1
Nociception-Antinociception Balance Monitoring
Boselli, E. (2025) · Springer eBooks · doi:10.1007/978-981-96-6178-7_10 · Cited by 1
Walter, U. (2021) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-1256-4791 · Cited by 1
de Aberasturi, Y. L. D. A.-J., de la Cueva, A. V., & Parraza, N. (2025) · International Journal of Nursing Studies Advances · doi:10.1016/j.ijnsa.2025.100431 · Cited by 1
New indications for peripheral pulse wave
Harju, J. (2018) · Tampere University Institutional Repository (Tampere University) · Cited by 1
Automated pupillometry in short-duration human spaceflight
Shirah, B. H., Aladdin, Y. S., Mason, C. E., Pandya, S., Gonzalez, Y. M., Persad, A. H., Lee, A. G., Ahmed, M. M., Ashemimry, M. N., & Sen, J. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-33918-9.00008-0 · Cited by 1
Miyata, K., & Kobayakawa, S. (2025) · Current Eye Research · doi:10.1080/02713683.2025.2469833 · Cited by 1
Evaluation of Pupillometry for CYP2D6 Phenotyping in Children Treated with Tramadol
Rodieux, F., Storelli, F., Curtin, F., Manzano, S., Gervaix, A., Posfay-Barbe, K. M., Desmeules, J. A., Daali, Y., & Samer, C. F. (2023) · Pharmaceuticals · doi:10.3390/ph16091227 · Cited by 1
Non-invasive Neuromonitoring: Near Infrared Spectroscopy and Pupillometry
Brogi, E. (2024) · Hot topics in acute care surgery and trauma · doi:10.1007/978-3-031-50117-3_8 · Cited by 1
Metadata
- Authors
- Larson, M. D., & Behrends, M.
- Venue
- Anesthesia & Analgesia
- Published
- 2015-06
- Volume
- 120
- Issue
- 6
- Pages
- 1242-1253
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2336988105
- Cited by
- 242
- References
- 106
- FWCI
- 18.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.