Portable Infrared Pupillometry: A Review
The DOI matches its Crossref record; 106 of the 106 references it cites were found in a registry or an index.
Abstract
Portable infrared pupillometers provide an objective measure of pupil size and pupillary reflexes, which for most clinicians was previously only a visual impression. But despite the fact that pupillometry can uncover aspects of how the human pupil reacts to drugs and noxious stimulation, the use of pupillometry has not gained widespread use among anesthesiologists and critical care physicians. The present review is an introduction to the physiology of pupillary reflexes and the currently established clinical applications of infrared pupillometry, which will hopefully encourage physicians to use this diagnostic tool in their clinical practice. Portable infrared pupillometry was introduced in 1989. The technology involves flooding the eye with infrared light and then measuring the reflected image on an infrared sensor. Pupil size, along with variables of the pupillary light reflex and pupillary reflex dilation, is calculated by the instrument and displayed on a screen immediately after each time-stamped measurement. Use of these instruments has uncovered aspects of how the human pupil reacts to drugs and noxious stimulation. The primary clinical applications for portable pupillometry have been in the assessment of brainstem function. Portable pupillometry is useful in the management of pain because it allows for assessments of the effect of opioids and in the titration of combined regional-general anesthetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These systems can analyze changes in pupil diameter at the millisecond level and evaluate multiple parameters, such as maximum and minimum pupil diameter, constriction and dilation velocities, latency, and symmetry, using standardized protocols (8,29).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [29]
In the citing paper
“Nevertheless, the high cost of devices and their limited availability across clinical settings remain major factors restricting the widespread use of quantitative pupillometry (29,38).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [29]
In the citing paper
“In recent years, pupillometric parameters such as the Pupillary Pain Index (PPI) and constriction velocity/latency have been reported as reliable indicators that assist in ensuring intraoperative and postoperative analgesia and in assessing pain severity (29,37,(49)(50)(51).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [29]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aston-Jones, G., & Cohen, J. D. (2005) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.28.061604.135709 · Cited by 4,472
Codeine Intoxication Associated with Ultrarapid CYP2D6 Metabolism
Gasche, Y., Daali, Y., Fathi, M., Chiappe, A., Cottini, S., Dayer, P., & Desmeules, J. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041888 · Cited by 702
Physiology and Pathophysiology of the Human Sympathoadrenal Neuroendocrine System
Bleich, H. L., Moore, M. J., & Cryer, P. E. (1980) · New England Journal of Medicine · doi:10.1056/nejm198008213030806 · Cited by 652
Human and macaque pupil responses driven by melanopsin-containing retinal ganglion cells
Gamlin, P. D. R., McDougal, D. H., Pokorny, J., Smith, V. C., Yau, K.-W., & Dacey, D. M. (2007) · Vision Research · doi:10.1016/j.visres.2006.12.015 · Cited by 617
How opioids inhibit GABA-mediated neurotransmission
Vaughan, C. W., Ingram, S. L., Connor, M. A., & Christie, M. J. (1997) · Nature · doi:10.1038/37610 · Cited by 507
Predicting the Outcome From Hypoxic-Ischemic Coma
Jorgensen, E. O. (1986) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1986.03370120043011 · Cited by 494
Predicting Outcome From Hypoxic-lschemic Coma
Levy, D. E. (1985) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1985.03350340072020 · Cited by 432
A unified formula for light-adapted pupil size
Watson, A. B., & Yellott, J. I. (2012) · Journal of Vision · doi:10.1167/12.10.12 · Cited by 399
Chen, J., Gombart, Z., Rogers, S., Gardiner, S., Cecil, S., & Bullock, R. (2011) · Surgical Neurology International · doi:10.4103/2152-7806.82248 · Cited by 314
Melanopsin signalling in mammalian iris and retina
Xue, T., Do, M. T. H., Riccio, A., Jiang, Z., Hsieh, J., Wang, H. C., Merbs, S. L., Welsbie, D. S., Yoshioka, T., Weissgerber, P., et al. (2011) · Nature · doi:10.1038/nature10567 · Cited by 303
Cited by
Items 201–279 of 279
Predicting Cognitive Workload in Visuospatial Tasks Using Pupillometry: A Machine Learning Approach
Karunathilake, S., Choudhury, N. A., Deep, A., & Saravanan, P. (2025) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/10711813251357928 · Cited by 1
Neurologische Untersuchung bewusstseinsgestörter Patienten auf Intensivstation – Schritt für Schritt
Biesel, J., Schirotzek, I., & Kollmar, R. (2020) · Intensivmedizin up2date · doi:10.1055/a-1164-8140 · Cited by 1
Ivanishcheva, Y. A., Zaitsev, A. Y., Kavochkin, A. A., Kabakov, D. G., Ma, V., Викторович, Д. К., Владимирович, Б. Д., & Popov, S. (2025) · Messenger of Anesthesiology and Resuscitation · doi:10.24884/2078-5658-2025-22-5-15-20 · Cited by 1
Pupilmate: A do-it-yourself frugal pupilometer
Chacko, R. K., Chandrakanth, P., Roy, A., Gosalia, H., Aggarwal, G., & Narendran, V. (2024) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_859_24 · Cited by 1
Tuinebreijer, W. E., & Koning, H. M. (2024) · The International Tinnitus Journal · doi:10.5935/0946-5448.20240013 · Cited by 1
Personalised Pain Treatment in Intensive Care Units - Monitoring of Nociception
Lončarić–Katušin, M., Ovčar, D., Žilić, A., Kogler, J., & Radoš, I. (2023) · Acta Clinica Croatica · doi:10.20471/acc.2023.62.s4.12 · Cited by 1
Park, S.-H., Kim, T. J., & Ko, S. (2024) · Acute and Critical Care · doi:10.4266/acc.2024.00983 · Cited by 1
Reliability assessment of iPhone-based pupillometry: A test-retest analysis
Dutta, P., Das, S., & Baishya, R. (2025) · The Eastern Eye · doi:10.25259/tee_9_2025 · Cited by 1
Braczkowska, M., Lepiarczyk, E., Glinka, L., Korzeniowska‐Kubacka, I., Radkowski, P., Mayzner‐Zawadzka, E., & Majewska, M. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15051840 · Cited by 1
Pupillométrie : une place dans le monitoring de la douleur et des sédations en soins palliatifs ?
Elyn, A., Mazerolles, M., Saffon, N., Bongard, V., & Rolland, Y. (2018) · Médecine Palliative · doi:10.1016/j.medpal.2018.09.004 · Cited by 1
Dhea, W., Utariani, A., & Susila, D. (2020) · Indian Journal of Forensic Medicine & Toxicology · doi:10.37506/ijfmt.v14i3.10763 · Cited by 1
A feasibility study of the Pupillary Pain Index measurement in Anesthetized Children
Kegels, N., Saldien, V., Hans, G. H., & Wildemeersch, D. (2021) · Anesthesia and Critical Care · doi:10.26502/acc.021 · Cited by 1
Newer brain monitoring techniques
Gomes, N. V., Wanner, P. M., & Goettel, N. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821776-4.00015-9 · Cited by 1
Effects of General Anesthesia on Ocular Refraction
Kawai, M., Ishikawa, H., Tatsui, S., Kanayama, S., Nakazawa, A., Matsuda, H., Okamoto, H., & Shoji, N. (2022) · Journal of Binocular Vision and Ocular Motility · doi:10.1080/2576117x.2022.2083542 · Cited by 1
Vlaenderen, D. V., Hans, G. H., Saldien, V., & Wildemeersch, D. (2022) · Acta Anaesthesiologica Belgica · doi:10.56126/73.s1.31 · Cited by 1
Chwojnicki, K., Wujtewicz, M. A., Filipczyk, A., Marszałek-Ratnicka, R., Czernik, J., Świątek, M., Gramza, G., Kukliński, J., Kapica, P., Chróst, H., et al. (2026) · Journal of Neurocritical Care · doi:10.18700/jnc.260012
Azam, M. H., Azam, M. H., Ahmed, T., Hannan, A., Shah, M. S., Aminpoor, H., Sarfaraz, R., & Sohaib, A. (2026) · The Pan-American Journal of Ophthalmology · doi:10.4103/pajo.pajo_126_25
Using Pupillometry to Evaluate Balance in Patients Implanted with a Cochleo-Vestibular Implant
Tang, J. Z., de Miguel, Á. R., González, J. C. F., Barreiro, S. B., Rodríguez-Montesdeoca, I., & Macías, Á. R. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13133797
Magnin, M., Goffette, L., Junot, S., Bonnet‐Garin, J., Allaouchiche, B., & Pouzot‐Nevoret, C. (2025) · Research in Veterinary Science · doi:10.1016/j.rvsc.2025.105982
Kim, J. H., Kwon, S. M., Kwon, M.-Y., Kim, C., Son, N., Kim, M., & Lee, S. (2026) · Journal of Korean Medical Science · doi:10.3346/jkms.2026.41.e313
Kumar, V. K. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-90903-7.00009-0
Monitorage non invasif de la nociception sous anesthésie générale par pupillométrie
Sabourdin, N. (2021) · theses.fr (ABES) · doi:10.70675/081c1d9ezde45z4a0ez89a9z6c88f518c01d
Robba, C. (2019) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.734510667.793559097
Neuro-Prognostication After Cardiopulmonary Resuscitation
He, J., & Wang, J. (2020) · Springer eBooks · doi:10.1007/978-981-15-7002-5_5
王, 萌. (2023) · Advances in Clinical Medicine · doi:10.12677/acm.2023.1381732
García, J. B., Ferrazzini, T., Coito, A. L., Brügger, D., & Abegg, M. H. (2025) · Journal of Eye Movement Research · doi:10.3390/jemr18060066
Pharmacometrics to facilitate decision-making in pain research and perioperative management
Marco‐Ariño, N. (2022) · Depósito Académico Digital Universidad de Navarra (University of Navarra) · doi:10.15581/10171/63138
POSTOPERATIVE PAIN IN CANINE ORTHOPEDIC SURGERY: MECHANISMS, ASSESSMENT, AND FUTURE PERSPECTIVES
AKÇASIZ, Z. N., & Erdikmen, D. O. (2026) · Аграрний вісник Причорномор я · doi:10.37000/abbsl.2026.120.12
Pain Assessment and Management in Veterinary Medicine
(2025) · Frontiers research topics · doi:10.3389/978-2-8325-5954-3
De, D., Adak, A., Bankura, B., Saha, J. K., Pal, S., Biswas, I., & Mondal, R. K. (2026) · SN Comprehensive Clinical Medicine · doi:10.1007/s42399-026-02836-4
Zhu, J., Song, Q., Sun, L., Zhang, Y., Sheng, D., Shi, C., & Jin, J. (2025) · American Journal of Translational Research · doi:10.62347/pruo9728
Yi-Hsiung, L., Huang, L.-Y., Pan, R., Chen, S.-Y., Chen, Y.-C., & Yeh, C. (2025) · Medicine · doi:10.1097/md.0000000000046244
Guglielminotti, J. R., & Longrois, D. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000897
García-González, M., García, I. A., & Jiménez‐Ortega, L. (2024) · Journal of Oral & Facial Pain and Headache · doi:10.22514/jofph.2024.039
Marcatori di sonno per la fenoconversione all'interno dello spettro delle alfa-sinucleinopatie
D’Este, G. (n.d.) · Archivio Istituzionale della Ricerca - Università Vita-Salute San Raffaele
Kim, I. S. Y., Balogun, O. O., Prescott, B. R., Saglam, H., Olson, D. M., Speir, K., Stutzman, S. E., Schneider, N., Aguilera, V., Lussier, B. L., et al. (2022) · doi:10.3389/fneur.2022.1046548.s002
Automated Pupillometry Following Sport-Related Concussion in National Level Rugby League Athletes
Brown, D. A. (2018) · Griffith Research Online · doi:10.25904/1912/1340
Obesity is associated with sympathetic nervous activation in school aged children
Teixeira, B. G. (2020) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/x9b8-5771
Development of a pupillometer to measure pain and nociception in horses
Karar, S. (2023) · HAL
Pupillenreflexdilatation zum Nozizeptionsmonitoring bei wachen Probanden
Skorupka, N. (2026) · Dokumentenrepositorium der RUB (Ruhr University Bochum) · doi:10.13154/294-14693
Pupilometria no diagnóstico da doença de alzheimer
Silva¹, B. F. D. (2017) · doi:10.14393/ufu.di.2017.93
Sasidharan, S., Nanayakkara, S., & Madhusudhan, S. (2025) · Current Medical Issues · doi:10.4103/cmi.cmi_33_25
Neurologische Untersuchung bewusstseinsgestörter Patienten auf Intensivstation – Schritt für Schritt
Biesel, J., Schirotzek, I., & Kollmar, R. (2024) · Neurologie up2date · doi:10.1055/a-2300-2878
Larson, M. D. (2024) · Cambridge University Press eBooks · doi:10.1017/9781009436274.018
Self-citationPinheiro, M. M. O. E. S. A. (2023) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/70w0-hn54
Trends in Research Related to Pupillometry From 1999 to 2025: A Bibliometric and Visualized AnalysisPreprint
Han, P., Hun, M., Nfumu, F. N. E., & Jiang, B. (2026) · Preprints.org · doi:10.20944/preprints202602.1764.v1
Fındık, H., Aydın, M. D., Uzun, F., Kaim, M., Kanat, A., Keleş, O. N., Kadıoğlu, H. H., Akyüz, M. E., & Zeynal, M. (2025) · Diagnostics · doi:10.3390/diagnostics15212696
Near-infrared OCT imaging for the assessment of anisocoria
Geller, A., Paltiel, O., & Kruger, J. M. (2026) · Eye · doi:10.1038/s41433-026-04536-8
Singh, P., Stutzman, S. E., Venkatachalam, A. M., Olson, D. M., Barnes, A., & Atem, F. (2021) · PubMed Central · doi:10.5935/0103-507x.20210065
Clinical utility of quantitative pupillometric monitoring in patients with acute brain injury
Campos, E., Álvarez, E. E. T., & Balanza, J. Á. L. (2025) · Medicina Clínica (English Edition) · doi:10.1016/j.medcle.2025.107046
Pupillary light reflex in acute heart failure patients
Xu, Q.-H. Z. (2024) · e_Buah
Pupillometry to show stress release during equine sports massage therapy
(2023) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2022.12.085
Reducing Opioid Dose Via Targeted Nociception Monitoring
Ende, J., & Faßl, J. (2020) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2020.0831
Vinclair, M., Schilte, C., Francony, G., & Payen, J. (2019) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004485
Yılmaz, R., Büyükbezirci, G., Arıcan, Ş., Kaya, A. Ö., & Asıl, M. (2023) · Journal of Surgery and Medicine · doi:10.28982/josam.7501
¿Es útil la pupilometría óptica cuantitativa en cuidados críticos?
Higuera-Lucas, J. (2023) · Revista del Hospital Juárez de México · doi:10.24875/rhjm.22000063
Guimarães, C. F. S., Scassola, C. M. C., da Silva, B. M. C., Miyahira, S. A., Hypólito, O. H. M., Cunha, T. S., & Casali, K. R. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-49404-8_58
Abelson, D., & Larson, M. D. (2024) · Pediatric Anesthesia · doi:10.1111/pan.14949
Self-citationMagnin, M., Chapelle, A., Junot, S., Allaouchiche, B., Schuhler, T., Lac, R., Bondoux, V., Hoareau, G. L., Kim, M., Victoni, T., et al. (2025) · Research in Veterinary Science · doi:10.1016/j.rvsc.2025.105915
Ivanishcheva, Y. A., Zaitsev, A. Y., Kavochkin, A. A., Ma, V., Викторович, Д. К., Владимирович, Б. Д., Popov, S. O., & Kuznetsova, A. A. (2025) · Messenger of Anesthesiology and Resuscitation · doi:10.24884/2078-5658-2025-22-6-14-22
タムラ, ト., Tamura, T., & 多村, 知. (2018) · Institutional Repositories DataBase (IRDB)
Konno, M. (2024) · Institutional Repositories DataBase (IRDB)
Automated pupillometry for detection of delirium in surgical intensive care patients
Míča, P., Lukeš, M., Pokorná, A., Hruda, J., Olson, L., Svoboda, M., & Čundrle, I. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1822468
Principes et protocoles en neuro-anesthésie-réanimation
Daccache, G. (2020) · Arnette eBooks · doi:10.3917/arne.gakub.2020.01.0107
Discordance between pupillometry indices: a matter of scale and sedation
Bouzat, P., Vilotitch, A., Gauss, T., & Taccone, F. S. (2026) · Critical Care · doi:10.1186/s13054-026-06428-5
Managing intracranial pressure, cerebral perfusion pressure, and oxygenation
Gallardo, Á. J. L. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-51365-7.00020-6
An Evidence Map of Pupillary Assessment in a Preselected Acute-Care Literature Archive
Li, C.-Y., Cheng, C.-Y., Chang, C., Ho, H., Liang, Y.-J., & Sun, J. (2026) · Diagnostics · doi:10.3390/diagnostics16213698
Metadata
- Authors
- Larson, M. D., & Behrends, M.
- Venue
- Anesthesia & Analgesia
- Published
- 2015-06
- Volume
- 120
- Issue
- 6
- Pages
- 1242-1253
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2336988105
- Cited by
- 242
- References
- 106
- FWCI
- 18.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.