Accuracy of Identification of the Cricothyroid Membrane in Female Subjects Using Palpation: An Observational Study
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The cricothyroid membrane (CTM) is the recommended site of access to the airway during cricothyroidotomy to provide emergency oxygenation. Despite the apparent simplicity of the technique, this rescue maneuver frequently fails to achieve its goals and complications are numerous. The reasons for this failure are unclear. We sought to determine the ability of physicians to correctly identify the CTM in female patients. METHODS: Using fluorescent "invisible" ink, the physician was asked to mark the CTM with the patient in the supine neutral position and then with the head extended. The actual level was identified using ultrasound and the distance between the actual and estimated margin of the CTM was measured. A correct estimation was defined as a mark made between the upper and lower limits of the membrane and within 5 mm of midline. Participants were also asked to assess the ease of CTM palpation using a 10-cm visual analog scoring (VAS) scale. RESULTS: Fifty-six patients participated of whom 15 were obese. In the supine neutral neck position, the CTM was identified in 10/41 vs 0/15 (P = 0.048) in nonobese versus obese, respectively. Of the 46 incorrectly identified CTMs in this position, 24 were above (maximum 3 cm) and 22 below (maximum 3 cm) the actual level. Similar results were observed when the patients were placed with the neck in the extended position; the CTM was identified correctly in 12/41 vs 1/15 nonobese and obese patients, respectively. The range of values was also extensive; the estimation of the position of the membrane was as high as 2.5 cm above and 4 cm below the actual level, and up to 1.6 cm laterally. Participating doctors found palpation of the CTM subjectively more difficult in the obese than nonobese groups; VAS score for palpation difficulty was 5.25 ± 2.5 vs 3.3 ± 2.5, respectively, P = 0.005. Using multiple linear regression, VAS scores for palpation correlated negatively with increased patient height (P < 0.001) and greater thyromental distance (P = 0.006), and correlated positively with increased sternomental distance (P = 0.011) and neck circumference (P = 0.001). CONCLUSIONS: Misidentification of the CTM in female patients is common and its localization is less precise in those who are obese. This has implications for the likely success of invasive airway access via the CTM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cook, T. M., Woodall, N., & Frerk, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer058 · Cited by 2,415 · cited 1×
“study, 15/29 (52%) cricothyroidotomies performed by anesthesiologists failed.(6) In other clinical series, misplacement”
Background
Cited by
Guidelines for the management of tracheal intubation in critically ill adults
Higgs, A., McGrath, B. A., Goddard, C., Rangasami, J., Suntharalingam, G., Gale, R., & Cook, T. M. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.021 · Cited by 900
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
The difficult airway with recommendations for management – Part 2 – The anticipated difficult airway
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0020-x · Cited by 276
Transtracheal jet ventilation in the “can’t intubate can’t oxygenate” emergency: a systematic review
Duggan, L. V., Ballantyne Scott, B., Law, J. A., Morris, I. R., Murphy, M. F., & Griesdale, D. E. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew192 · Cited by 114
Airway management outside the operating room: how to better prepare
Brindley, P. G., Beed, M., Law, J. A., Hung, O., Levitan, R., Murphy, M. F., & Duggan, L. V. (2017) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-017-0834-z · Cited by 30
“Fewer than 50% of anesthesia providers can correctly identify the cricothyroid membrane by external palpation.(35-37) Therefore, the use of ultrasonography can be considered if landmarks are obscured, although it could cause further distraction, delay, and crowding.”
Background
Metadata
- Authors
- Aslani, A., Ng, S.-C., Hurley, M., McCarthy, K. F., McNicholas, M., & McCaul, C. L.
- Venue
- Anesthesia & Analgesia
- Published
- 2012-05
- Volume
- 114
- Issue
- 5
- Pages
- 987-992
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2131604730
- Cited by
- 141
- References
- 1
- FWCI
- 12.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of Identification of the Cricothyroid Membrane in Female Subjects Using Palpation: An Observational Study. https://app.cochat.ai/papers/10.1213/ane.0b013e31824970ba
- The paper
- Aslani, A., Ng, S.-C., Hurley, M., McCarthy, K. F., McNicholas, M., & McCaul, C. L. (2012). Accuracy of Identification of the Cricothyroid Membrane in Female Subjects Using Palpation: An Observational Study. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0b013e31824970ba
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.