The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Cerebral Arterial Diameters during Changes in Blood Pressure and Carbon Dioxide during Craniotomy
Abstract
Forty-five measurements of diameters of 12 human cerebral arteries were performed during 10 craniotomies under moderate changes in mean blood pressure and end tidal CO2. The mean change in blood pressure was 30 +/- 16 mm Hg (standard deviation) and that of end tidal CO2 was 14 +/- 6 mm Hg (standard deviation). These changes were induced with nitroprusside, phenylephrine, and adjustment of ventilator rate. Measurements were made through the operating microscope focused at the highest power, with meticulous attention to constant angle and distance from the artery. The mean diameter change in the large cerebral arteries (carotid, middle cerebral artery, vertebral artery) was less than 4%, but the smaller arteries (anterior cerebral artery, M2 segment of middle cerebral artery) showed diameter changes as large as 29% and 21% to end tidal CO2 and blood pressure changes, respectively. These data suggest that at the time of craniotomy, diameters of the large cerebral vessels do not significantly change during moderate variations in blood pressure and CO2, but that larger changes may occur in smaller vessels. This constancy of diameter suggests that the transcranial Doppler velocities obtained during intraoperative monitoring of craniotomies may closely reflect blood flow through the insonated artery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries
Aaslid, R., Markwalder, T.-M., & Nornes, H. (1982) · Journal of Neurosurgery · doi:10.3171/jns.1982.57.6.0769 · Cited by 3,046
Cerebral autoregulation dynamics in humans.
Aaslid, R., Lindegaard, K. F., Sorteberg, W., & Nornes, H. (1989) · Stroke · doi:10.1161/01.str.20.1.45 · Cited by 1,632
Responses of cerebral arteries and arterioles to acute hypotension and hypertension
Kontos, H. A., Wei, E. P., Navari, R. M., Levasseur, J. E., Rosenblum, W. I., & Patterson, J. L. (1978) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1978.234.4.h371 · Cited by 699
Transcranial Doppler Sonography
(1986) · Springer eBooks · doi:10.1007/978-3-7091-8864-4 · Cited by 541
Markwalder, T.-M., Grolimund, P., Seiler, R. W., Roth, F., & Aaslid, R. (1984) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1984.54 · Cited by 463
Validity of cerebral arterial blood flow calculations from velocity measurements.
Kontos, H. A. (1989) · Stroke · doi:10.1161/01.str.20.1.1 · Cited by 396
Huber, P., & Handa, J. (1967) · Investigative Radiology · doi:10.1097/00004424-196701000-00016 · Cited by 358
Lindegaard, K. F., Lundar, T., Wiberg, J., Sjøberg, D., Aaslid, R., & Nornes, H. (1987) · Stroke · doi:10.1161/01.str.18.6.1025 · Cited by 309
Arterial behavior and blood circulation in the brain
(1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90089-7 · Cited by 133
Hemodilution causes size-dependent constriction of pial arterioles in the cat
Hudak, M. L., Jones, M., Popel, A. S., Koehler, R. C., Traystman, R. J., & Zeger, S. L. (1989) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1989.257.3.h912 · Cited by 63
Cited by
Comparison of Static and Dynamic Cerebral Autoregulation Measurements
Tiecks, F. P., Lam, A. M., Aaslid, R., & Newell, D. W. (1995) · Stroke · doi:10.1161/01.str.26.6.1014 · Cited by 875
Integrative regulation of human brain blood flow
Willie, C. K., Tzeng, Y., Fisher, J. A., & Ainslie, P. N. (2014) · The Journal of Physiology · doi:10.1113/jphysiol.2013.268953 · Cited by 872
Transfer function analysis of dynamic cerebral autoregulation in humans
Zhang, R., Zuckerman, J. H., Giller, C. A., & Levine, B. D. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.1.h233 · Cited by 848
Self-citationMRI Measures of Middle Cerebral Artery Diameter in Conscious Humans During Simulated Orthostasis
Serrador, J. M., Picot, P. A., Rutt, B. K., Shoemaker, J. K., & Bondar, R. L. (2000) · Stroke · doi:10.1161/01.str.31.7.1672 · Cited by 717
Ainslie, P. N., & Duffin, J. (2009) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.91008.2008 · Cited by 568
Metadata
- Authors
- Giller, C. A., Bowman, G., Dyer, H., Mootz, L., & Krippner, W.
- Venue
- Neurosurgery
- Published
- 1993-05-01
- Volume
- 32
- Issue
- 5
- Pages
- 737-742
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2032656032
- Cited by
- 659
- References
- 12
- FWCI
- 12.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cerebral Arterial Diameters during Changes in Blood Pressure and Carbon Dioxide during Craniotomy. https://app.cochat.ai/papers/10.1227/00006123-199305000-00006
- The paper
- Giller, C. A., Bowman, G., Dyer, H., Mootz, L., & Krippner, W. (1993). Cerebral Arterial Diameters during Changes in Blood Pressure and Carbon Dioxide during Craniotomy. Neurosurgery. https://doi.org/10.1227/00006123-199305000-00006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.