Cerebral Arterial Diameters during Changes in Blood Pressure and Carbon Dioxide during Craniotomy
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Forty-five measurements of diameters of 12 human cerebral arteries were performed during 10 craniotomies under moderate changes in mean blood pressure and end tidal CO2. The mean change in blood pressure was 30 +/- 16 mm Hg (standard deviation) and that of end tidal CO2 was 14 +/- 6 mm Hg (standard deviation). These changes were induced with nitroprusside, phenylephrine, and adjustment of ventilator rate. Measurements were made through the operating microscope focused at the highest power, with meticulous attention to constant angle and distance from the artery. The mean diameter change in the large cerebral arteries (carotid, middle cerebral artery, vertebral artery) was less than 4%, but the smaller arteries (anterior cerebral artery, M2 segment of middle cerebral artery) showed diameter changes as large as 29% and 21% to end tidal CO2 and blood pressure changes, respectively. These data suggest that at the time of craniotomy, diameters of the large cerebral vessels do not significantly change during moderate variations in blood pressure and CO2, but that larger changes may occur in smaller vessels. This constancy of diameter suggests that the transcranial Doppler velocities obtained during intraoperative monitoring of craniotomies may closely reflect blood flow through the insonated artery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries
Aaslid, R., Markwalder, T.-M., & Nornes, H. (1982) · Journal of Neurosurgery · doi:10.3171/jns.1982.57.6.0769 · Cited by 3,046
Cerebral autoregulation dynamics in humans.
Aaslid, R., Lindegaard, K. F., Sorteberg, W., & Nornes, H. (1989) · Stroke · doi:10.1161/01.str.20.1.45 · Cited by 1,632
Responses of cerebral arteries and arterioles to acute hypotension and hypertension
Kontos, H. A., Wei, E. P., Navari, R. M., Levasseur, J. E., Rosenblum, W. I., & Patterson, J. L. (1978) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1978.234.4.h371 · Cited by 699
Transcranial Doppler Sonography
(1986) · Springer eBooks · doi:10.1007/978-3-7091-8864-4 · Cited by 541
Markwalder, T.-M., Grolimund, P., Seiler, R. W., Roth, F., & Aaslid, R. (1984) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1984.54 · Cited by 463
Validity of cerebral arterial blood flow calculations from velocity measurements.
Kontos, H. A. (1989) · Stroke · doi:10.1161/01.str.20.1.1 · Cited by 396
Huber, P., & Handa, J. (1967) · Investigative Radiology · doi:10.1097/00004424-196701000-00016 · Cited by 371
Lindegaard, K. F., Lundar, T., Wiberg, J., Sjøberg, D., Aaslid, R., & Nornes, H. (1987) · Stroke · doi:10.1161/01.str.18.6.1025 · Cited by 309
Arterial behavior and blood circulation in the brain
(1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90089-7 · Cited by 133
Hemodilution causes size-dependent constriction of pial arterioles in the cat
Hudak, M. L., Jones, M., Popel, A. S., Koehler, R. C., Traystman, R. J., & Zeger, S. L. (1989) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1989.257.3.h912 · Cited by 63
Cited by
Comparison of Static and Dynamic Cerebral Autoregulation Measurements
Tiecks, F. P., Lam, A. M., Aaslid, R., & Newell, D. W. (1995) · Stroke · doi:10.1161/01.str.26.6.1014 · Cited by 875
Integrative regulation of human brain blood flow
Willie, C. K., Tzeng, Y., Fisher, J. A., & Ainslie, P. N. (2014) · The Journal of Physiology · doi:10.1113/jphysiol.2013.268953 · Cited by 872
Transfer function analysis of dynamic cerebral autoregulation in humans
Zhang, R., Zuckerman, J. H., Giller, C. A., & Levine, B. D. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.1.h233 · Cited by 848
Self-citationMRI Measures of Middle Cerebral Artery Diameter in Conscious Humans During Simulated Orthostasis
Serrador, J. M., Picot, P. A., Rutt, B. K., Shoemaker, J. K., & Bondar, R. L. (2000) · Stroke · doi:10.1161/01.str.31.7.1672 · Cited by 717
Ainslie, P. N., & Duffin, J. (2009) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.91008.2008 · Cited by 568
Assessment of cerebral pressure autoregulation in humans - a review of measurement methods
Panerai, R. B. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/3/001 · Cited by 508
Cerebral blood flow during exercise: mechanisms of regulation
Ogoh, S., & Ainslie, P. N. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00573.2009 · Cited by 502
van Beek, A. H., Claassen, J. A., Rikkert, M. G. O., & Jansen, R. W. (2008) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2008.13 · Cited by 485
“It has been shown in (neuro)surgical patients that the diameter of the MCA does not significantly increase or decrease during, respectively, a mean decrease or increase in BP of 30 (s.d. 16) mm Hg (Giller et al, 1993; Newell et al, 1994).”
Regional brain blood flow in man during acute changes in arterial blood gases
Willie, C. K., Macleod, D. B., Shaw, A. D., Smith, K. J., Tzeng, Y. C., Eves, N. D., Ikeda, K., Graham, J., Lewis, N. C., Day, T. A., et al. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2012.228551 · Cited by 483
Autonomic Neural Control of Dynamic Cerebral Autoregulation in Humans
Zhang, R., Zuckerman, J. H., Iwasaki, K., Wilson, T. E., Crandall, C. G., & Levine, B. D. (2002) · Circulation · doi:10.1161/01.cir.0000031798.07790.fe · Cited by 469
Elevation in cerebral blood flow velocity with aerobic fitness throughout healthy human ageing
Ainslie, P. N., Cotter, J. D., George, K. P., Lucas, S., Murrell, C., Shave, R., Thomas, K. N., Williams, M. J. A., & Atkinson, G. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2008.158279 · Cited by 444
“Although we used Doppler ultrasound to measure flow velocity, rather than blood flow, in the MCA, previous reports indicate that MCAv is a reliable index of cerebral blood flow (Kirkham et al. 1986; Giller et al. 1993; Valdueza et al. 1997; Serrador et al. 2000; Peebles et al. 2007).”
MethodDynamic and Static Cerebral Autoregulation during Isoflurane, Desflurane, and Propofol Anesthesia
Strebel, S., Lam, A., Matta, B., Mayberg, T. S., Aaslid, R., & Newell, D. W. (1995) · Anesthesiology · doi:10.1097/00000542-199507000-00008 · Cited by 437
Monitoring the injured brain: ICP and CBF
Steiner, L. A., & Andrews, P. J. D. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael110 · Cited by 400
Syncope, cerebral perfusion, and oxygenation
Van Lieshout, J. J., Wieling, W., Karemaker, J. M., & Secher, N. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00260.2002 · Cited by 365
“More direct observations made during craniotomy reveal that the vessel diameter does not change significantly during variations in MAP of a magnitude that surpasses the changes manifest in response to orthostasis (42).”
BackgroundCoverdale, N. S., Gati, J. S., Opalevych, O., Perrotta, A., & Shoemaker, J. K. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00285.2014 · Cited by 348
Cerebral blood flow and metabolism during exercise: implications for fatigue
Secher, N. H., Seifert, T., & Van Lieshout, J. J. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00853.2007 · Cited by 344
“Thus the diameter of large cerebral arteries does not change significantly during exercise, and regulation of CBF takes place in the smaller arteries (28).”
BackgroundVerbree, J., Bronzwaer, A.-S. G. T., Ghariq, E., Versluis, M. J., Daemen, M. J. A. P., van Buchem, M. A., Dahan, A., van Lieshout, J. J., & van Osch, M. J. P. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00651.2014 · Cited by 303
Cerebral Autoregulation: From Models to Clinical Applications
Panerai, R. B. (2008) · Cardiovascular Engineering · doi:10.1007/s10558-007-9044-6 · Cited by 295
Albanese, J., Arnaud, S., Rey, M., Thomachot, L., Alliez, B., & Martin, C. (1997) · Anesthesiology · doi:10.1097/00000542-199712000-00011 · Cited by 284
Influence of Changes in Blood Pressure on Cerebral Perfusion and Oxygenation
Lucas, S. J. E., Tzeng, Y. C., Galvin, S. D., Thomas, K. N., Ogoh, S., & Ainslie, P. N. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.146290 · Cited by 282
Tarumi, T., & Zhang, R. (2018) · Journal of Neurochemistry · doi:10.1111/jnc.14234 · Cited by 278
Hypocapnia and the injured brain: More harm than benefit
Curley, G., Kavanagh, B. P., & Laffey, J. G. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181d8cf2b · Cited by 257
Impaired Cerebral Autoregulation in Patients With Malignant Hypertension
Immink, R. V., van den Born, B.-J. H., van Montfrans, G. A., Koopmans, R. P., Karemaker, J. M., & van Lieshout, J. J. (2004) · Circulation · doi:10.1161/01.cir.0000144472.08647.40 · Cited by 243
Hyperventilation in Head Injury
Stocchetti, N., Maas, A. I. R., Chieregato, A., & van der Plas, A. A. (2005) · Chest · doi:10.1378/chest.127.5.1812 · Cited by 235
Stroobant, N., & Vingerhoets, G. (2000) · Neuropsychology Review · doi:10.1023/a:1026412811036 · Cited by 234
“Although further research is warranted, it is generally assumed that the diameter of the large cerebral vessels does not significantly change under a variety of physiological stimuli ( Giller et al., 1993; Kontos, 1989).”
BackgroundWilson, M. H., Edsell, M. E., Davagnanam, I., Hirani, S. P., Martin, D. S., Levett, D. Z., Thornton, J. S., Golay, X., Strycharczuk, L., Newman, S. P., et al. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.81 · Cited by 226
“Inthe past, the measurement of MCA diameter (MCA Diam ) has only been possible by direct vision at surgery (Giller et al , 1993), by use of contrast angiography (Du Boulay and Symon, 1971) or magnetic resonance angiography (MRA)—techniques inappropriate for remote extreme altitude field studies.”
Dynamic cerebral autoregulation during repeated squat-stand maneuvers
Claassen, J. A. H. R., Levine, B. D., & Zhang, R. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90822.2008 · Cited by 214
“CBFV, cm/s 55 (13) 53 (8) 52 (9) 55 (11) 0.”
BackgroundEffect of CO2on dynamic cerebral autoregulation measurement
Panerai, R. B., Deverson, S. T., Mahony, P., Hayes, P., & Evans, D. H. (1999) · Physiological Measurement · doi:10.1088/0967-3334/20/3/304 · Cited by 210
Czosnyka, M., Richards, H. K., Whitehouse, H. E., & Pickard, J. D. (1996) · Journal of Neurosurgery · doi:10.3171/jns.1996.84.1.0079 · Cited by 208
Linear and nonlinear analysis of human dynamic cerebral autoregulation
Panerai, R. B., Dawson, S. L., & Potter, J. F. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.3.h1089 · Cited by 208
“Although the Doppler technique measures blood velocity rather than absolute flow, these two quantities will change in parallel unless the diameter of the insonated vessel changes significantly, which has not been shown to occur (11, 18).”
BackgroundThe impact of cerebrovascular aging on vascular cognitive impairment and dementia
Yang, T., Sun, Y., Lu, Z., Leak, R. K., & Zhang, F. (2017) · Ageing Research Reviews · doi:10.1016/j.arr.2016.09.007 · Cited by 205
“…to PaCO2 throughout large arteries, ranging from the internal carotid arteries and vertebral arteries (Willie et al., 2012), intracranial arteries (Giller et al., 1993; Willie et al., 2011; Willie et al., 2014a), to the small pial arterioles (Wolff and Lennox, 1930), and even the capillaries of…”
Blanco, P. J., Müller, L. O., & Spence, J. D. (2017) · Stroke and Vascular Neurology · doi:10.1136/svn-2017-000087 · Cited by 202
“21 A study in neurosurgical patients with subarachnoid haemorrhage 22”
BackgroundSato, K., Sadamoto, T., Hirasawa, A., Oue, A., Subudhi, A. W., Miyazawa, T., & Ogoh, S. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2012.230425 · Cited by 197
“In addition, Giller et al. (1993) found a change in BA diameter during moderate variation of MAP and PaCO2 .”
BackgroundCerebrovascular Consequences of Obstructive Sleep Apnea
Durgan, D. J., & Bryan, R. M. (2012) · Journal of the American Heart Association · doi:10.1161/jaha.111.000091 · Cited by 197
Dynamic But Not Static Cerebral Autoregulation Is Impaired in Acute Ischaemic Stroke
Dawson, S. L., Blake, M. J., Panerai, R. B., & Potter, J. F. (2000) · Cerebrovascular Diseases · doi:10.1159/000016041 · Cited by 194
Hypocapnia and Cerebral Hypoperfusion in Orthostatic Intolerance
Novak, V., Spies, J. M., Novak, P., McPhee, B. R., Rummans, T. A., & Low, P. A. (1998) · Stroke · doi:10.1161/01.str.29.9.1876 · Cited by 191
Poulin, M. J., & Robbins, P. A. (1996) · Stroke · doi:10.1161/01.str.27.12.2244 · Cited by 191
Transfer Function Analysis of Cerebral Autoregulation Dynamics in Autonomic Failure Patients
Blaber, A. P., Bondar, R. L., Stein, F., Dunphy, P. T., Moradshahi, P., Kassam, M. S., & Freeman, R. (1997) · Stroke · doi:10.1161/01.str.28.9.1686 · Cited by 181
Cerebrovascular Response to Carbon Dioxide in Patients with Congestive Heart Failure
Xie, A., Skatrud, J. B., Khayat, R., Dempsey, J. A., Morgan, B., & Russell, D. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-807oc · Cited by 177
Tiecks, F. P., Lam, A. M., Matta, B. F., Strebel, S., Douville, C., & Newell, D. W. (1995) · Stroke · doi:10.1161/01.str.26.8.1386 · Cited by 173
Claassen, J. A. H. R., Zhang, R., Fu, Q., Witkowski, S., & Levine, B. D. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00906.2006 · Cited by 172
“An additional limitation, inherent to the use of TCD, is that CBFV was measured to reflect changes in CBF.”
InfluentialAutonomic Neural Control of the Cerebral Vasculature: Acute Hypotension
Ogoh, S., Brothers, R. M., Eubank, W. L., & Raven, P. B. (2008) · Stroke · doi:10.1161/strokeaha.107.510008 · Cited by 172
Impaired cerebral autoregulation in obstructive sleep apnea
Urbano, F., Roux, F., Schindler, J., & Mohsenin, V. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90900.2008 · Cited by 168
“Measurement of middle cerebral artery diameters in humans have shown that the diameters do not change during orthostatic hypotension or alteration of end-tidal CO2 (16, 38).”
BackgroundZhang, R., Zuckerman, J. H., & Levine, B. D. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.3.1113 · Cited by 161
“Angiographic study (17) and direct visualization of the MCA during surgery (13) have suggested that, during a variety of stimuli”
Jordan, J., Shannon, J. R., Diedrich, A., Black, B., Costa, F., Robertson, D., & Biaggioni, I. (2000) · Hypertension · doi:10.1161/01.hyp.36.3.383 · Cited by 161
Subudhi, A. W., Lorenz, M. C., Fulco, C. S., & Roach, R. C. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01104.2007 · Cited by 155
CAREY, B. J., EAMES, P. J., PANERAI, R. B., & POTTER, J. F. (2001) · Clinical Science · doi:10.1042/cs20010021 · Cited by 79
Jordan, J., Shannon, J. R., Black, B. K., Paranjape, S. Y., Barwise, J., & Robertson, D. (1998) · Hypertension · doi:10.1161/01.hyp.32.4.699 · Cited by 56
Wells, R., Malik, V., Brooks, A. G., Linz, D., Elliott, A. D., Sanders, P., Page, A., Baumert, M., & Lau, D. H. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.120.017861 · Cited by 28
Metadata
- Authors
- Giller, C. A., Bowman, G., Dyer, H., Mootz, L., & Krippner, W.
- Venue
- Neurosurgery
- Published
- 1993-05-01
- Volume
- 32
- Issue
- 5
- Pages
- 737-742
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2032656032
- Cited by
- 659
- References
- 12
- FWCI
- 12.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.