Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 162

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Brain Oxygen, CO2, pH, and Temperature Monitoring

Zauner, Alois, Bullock, Ross, Di, Xiao, Young, Harold F. · 1995 · Neurosurgery

Abstract

Currently, no ideal method exists for monitoring the injured brain. Recently, a single, compact, fiberoptic sensor has become available for measuring oxygen, CO2, pH and temperature in blood. We have adapted this instrument for continuous use in brain tissue to measure oxygen tension, carbon dioxide tension (pCO2), pH, and temperature. To evaluate this new technique, we produced hypercapnia, hypocapnia, intracranial pressure increase, and hypoxemia in seven normal cats. In an additional six animals, sensors were placed within a zone of focal brain ischemia induced by occluding the left middle cerebral artery. The sensor readings were compared with cerebral blood flow measurements, intracranial pressure, and brain histological findings. An in vitro experiment was also performed using human blood to test the accuracy of the sensor over a wide range of pCO2 and oxygen tension values. After careful precalibration and rigid cranium fixation, stable measurements could be obtained throughout the 6- to 8-hour experiments. In normal animals, brain oxygen was 42 +/- 9 mm Hg, brain CO2 was 59 +/- 14 mm Hg, brain pH was 7.0 +/- 0.2, and brain temperature was 36.7 +/- 0.7 degrees C. Hypocapnia and hypoxemia produced a significant decline in tissue oxygen (< or = 30 +/- 3 mm Hg; P < 0.001), whereas hypercapnia caused by hypoventilation and intracranial pressure increase produced a significant increase in tissue CO2 (> or = 74 +/- 4 mm Hg; P < 0.001). Focal ischemia produced a rapid 42% decline in brain oxygen (25 +/- 7 mm Hg) and a 25% increase in tissue pCO2 (71 +/- 23 mm Hg). Brain oxygen further decreased to 19 +/- 6 mm Hg toward the end of the experiment, 4 hours later. After middle cerebral artery occlusion, the regional cerebral blood flow decreased to 10 +/- 5 ml per 100 g per minute, within the 1st hour, from a baseline value of 65 +/- 15 ml per 100 g per minute. It then gradually increased to 15 +/- 5 ml per 100 g per minute by the end of the 4-hour experiment. Brain pH was closely and inversely related to brain CO2. The brain temperature in the focally ischemic tissue decreased from 36.7 +/- 0.7 to 35.5 +/- 1.6 degrees C by the end of the experiment. The in vitro experiment demonstrated good linear correlation between the sensor readings and the blood gas analysis. Continuous monitoring of oxygen, CO2, pH, and temperature in damaged or at-risk brain tissue using a single sensor is now feasible and will, thus, allow improved continuous monitoring of neurosurgical patients who are at risk of significant secondary brain damage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/00006123-199512000-00017

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 162

Metadata

Authors
Zauner, A., Bullock, R., Di, X., & Young, H. F.
Venue
Neurosurgery
Published
1995-12-01
Volume
37
Issue
6
Pages
1168-1177
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W2047100038
Cited by
162
References
1
FWCI
8.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Brain Oxygen, CO2, pH, and Temperature Monitoring. https://app.cochat.ai/papers/10.1227/00006123-199512000-00017
The paper
Zauner, A., Bullock, R., Di, X., & Young, H. F. (1995). Brain Oxygen, CO2, pH, and Temperature Monitoring. Neurosurgery. https://doi.org/10.1227/00006123-199512000-00017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.