Brain Oxygen, CO2, pH, and Temperature Monitoring
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Currently, no ideal method exists for monitoring the injured brain. Recently, a single, compact, fiberoptic sensor has become available for measuring oxygen, CO2, pH and temperature in blood. We have adapted this instrument for continuous use in brain tissue to measure oxygen tension, carbon dioxide tension (pCO2), pH, and temperature. To evaluate this new technique, we produced hypercapnia, hypocapnia, intracranial pressure increase, and hypoxemia in seven normal cats. In an additional six animals, sensors were placed within a zone of focal brain ischemia induced by occluding the left middle cerebral artery. The sensor readings were compared with cerebral blood flow measurements, intracranial pressure, and brain histological findings. An in vitro experiment was also performed using human blood to test the accuracy of the sensor over a wide range of pCO2 and oxygen tension values. After careful precalibration and rigid cranium fixation, stable measurements could be obtained throughout the 6- to 8-hour experiments. In normal animals, brain oxygen was 42 +/- 9 mm Hg, brain CO2 was 59 +/- 14 mm Hg, brain pH was 7.0 +/- 0.2, and brain temperature was 36.7 +/- 0.7 degrees C. Hypocapnia and hypoxemia produced a significant decline in tissue oxygen (< or = 30 +/- 3 mm Hg; P < 0.001), whereas hypercapnia caused by hypoventilation and intracranial pressure increase produced a significant increase in tissue CO2 (> or = 74 +/- 4 mm Hg; P < 0.001). Focal ischemia produced a rapid 42% decline in brain oxygen (25 +/- 7 mm Hg) and a 25% increase in tissue pCO2 (71 +/- 23 mm Hg). Brain oxygen further decreased to 19 +/- 6 mm Hg toward the end of the experiment, 4 hours later. After middle cerebral artery occlusion, the regional cerebral blood flow decreased to 10 +/- 5 ml per 100 g per minute, within the 1st hour, from a baseline value of 65 +/- 15 ml per 100 g per minute. It then gradually increased to 15 +/- 5 ml per 100 g per minute by the end of the 4-hour experiment. Brain pH was closely and inversely related to brain CO2. The brain temperature in the focally ischemic tissue decreased from 36.7 +/- 0.7 to 35.5 +/- 1.6 degrees C by the end of the experiment. The in vitro experiment demonstrated good linear correlation between the sensor readings and the blood gas analysis. Continuous monitoring of oxygen, CO2, pH, and temperature in damaged or at-risk brain tissue using a single sensor is now feasible and will, thus, allow improved continuous monitoring of neurosurgical patients who are at risk of significant secondary brain damage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Obrist, W. D., Langfitt, T. W., Jaggi, J. L., Cruz, J., & Gennarelli, T. A. (1984) · Journal of Neurosurgery · doi:10.3171/jns.1984.61.2.0241 · Cited by 835
Circulation and Energy Metabolism of the Brain
Clarke, D. D., & Sokoloff, L. (1999) · Cited by 732
Krogh, A. (1919) · The Journal of Physiology · doi:10.1113/jphysiol.1919.sp001838 · Cited by 647
Therapeutic modulation of brain temperature: relevance to ischemic brain injury.
Ginsberg, M. D., Sternau, L., Globus, M. Y. ‐., Dietrich, W. D., & Busto, R. (1992) · PubMed · Cited by 429
Continuous monitoring of jugular venous oxygen saturation in head-injured patients
Sheinberg, M., Kanter, M. J., Robertson, C. S., Contant, C. F., Narayan, R. K., & Grossman, R. G. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.76.2.0212 · Cited by 422
Cerebral arteriovenous oxygen difference as an estimate of cerebral blood flow in comatose patients
Robertson, C. S., Narayan, R. K., Gokaslan, Z. L., Pahwa, R., Grossman, R. G., Caram, P., & Allen, E. (1989) · Journal of Neurosurgery · doi:10.3171/jns.1989.70.2.0222 · Cited by 388
Regional cerebral blood flow, intracranial pressure, and brain metabolism in comatose patients
Bruce, D. A., Langfitt, T. W., Miller, J. D., Schutz, H., Vapalahti, M. P., Stanek, A., & Goldberg, H. I. (1973) · Journal of Neurosurgery · doi:10.3171/jns.1973.38.2.0131 · Cited by 325
Die Sauerstoffdiffusion im Gehirn: Ein Beitrag zur Frage der Sauerstoffversorgung der Organe
Thews, G. (1960) · Pfl�gers Archiv f�r die Gesamte Physiologie des Menschen und der Tiere · doi:10.1007/bf00363005 · Cited by 185
Cited by
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Keeley, T. P., & Mann, G. E. (2019) · Physiological Reviews · doi:10.1152/physrev.00041.2017 · Cited by 329
Menzel, M., Doppenberg, E. M. R., Zauner, A., Soukup, J., Reinert, M. M., & Bullock, R. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.91.1.0001 · Cited by 303
Self-citationHyperventilation in Head Injury
Stocchetti, N., Maas, A. I. R., Chieregato, A., & van der Plas, A. A. (2005) · Chest · doi:10.1378/chest.127.5.1812 · Cited by 235
Vajkoczy, P., Roth, H., Horn, P., Lucke, T., Thomé, C., Hubner, U., Martin, G. T., Zappletal, C., Klar, E., Schilling, L., et al. (2000) · Journal of Neurosurgery · doi:10.3171/jns.2000.93.2.0265 · Cited by 229
Zauner, A., Doppenberg, E. M. R., Woodward, J. J., Choi, S. C., Young, H. F., & Bullock, R. (1997) · Neurosurgery · doi:10.1097/00006123-199711000-00011 · Cited by 218
Self-citationHigher hemoglobin is associated with improved outcome after subarachnoid hemorrhage*
Naidech, A. M., Jovanovic, B., Wartenberg, K. E., Parra, A., Ostapkovich, N., Connolly, E. S., Mayer, S. A., & Commichau, C. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000284516.17580.2c · Cited by 191
“correlate with decreasing HGB (28) and cerebral ischemia (29, 30) in animal models.”
BackgroundKorostynska, O., Arshak, K., Gill, E., & Arshak, A. (2007) · Sensors · doi:10.3390/s7123027 · Cited by 184
“75 during the brain insult and a continuous monitoring system would be beneficial in the treatment of comatose neurosurgical patients and those who have suffered traumatic brain injury, hypoxic, ischemic brain insult and so forth [20].”
Soukup, J., Zauner, A., Doppenberg, E. M. R., Menzel, M., Gilman, C., Young, H. F., & Bullock, R. (2002) · Journal of Neurotrauma · doi:10.1089/089771502753754046 · Cited by 165
“A miniaturized multiparameter probe (Paratrend 7, Dia-metrics Medical Inc., Roseville, MN) was used for continuous measurement of brain tissue pO 2 , pCO 2 , pH, and temperature (Zauner et al., 1995).”
Self-citation
Metadata
- Authors
- Zauner, A., Bullock, R., Di, X., & Young, H. F.
- Venue
- Neurosurgery
- Published
- 1995-12-01
- Volume
- 37
- Issue
- 6
- Pages
- 1168-1177
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2047100038
- Cited by
- 162
- References
- 28
- FWCI
- 8.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.