Brain Oxygen, CO2, pH, and Temperature Monitoring
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Currently, no ideal method exists for monitoring the injured brain. Recently, a single, compact, fiberoptic sensor has become available for measuring oxygen, CO2, pH and temperature in blood. We have adapted this instrument for continuous use in brain tissue to measure oxygen tension, carbon dioxide tension (pCO2), pH, and temperature. To evaluate this new technique, we produced hypercapnia, hypocapnia, intracranial pressure increase, and hypoxemia in seven normal cats. In an additional six animals, sensors were placed within a zone of focal brain ischemia induced by occluding the left middle cerebral artery. The sensor readings were compared with cerebral blood flow measurements, intracranial pressure, and brain histological findings. An in vitro experiment was also performed using human blood to test the accuracy of the sensor over a wide range of pCO2 and oxygen tension values. After careful precalibration and rigid cranium fixation, stable measurements could be obtained throughout the 6- to 8-hour experiments. In normal animals, brain oxygen was 42 +/- 9 mm Hg, brain CO2 was 59 +/- 14 mm Hg, brain pH was 7.0 +/- 0.2, and brain temperature was 36.7 +/- 0.7 degrees C. Hypocapnia and hypoxemia produced a significant decline in tissue oxygen (< or = 30 +/- 3 mm Hg; P < 0.001), whereas hypercapnia caused by hypoventilation and intracranial pressure increase produced a significant increase in tissue CO2 (> or = 74 +/- 4 mm Hg; P < 0.001). Focal ischemia produced a rapid 42% decline in brain oxygen (25 +/- 7 mm Hg) and a 25% increase in tissue pCO2 (71 +/- 23 mm Hg). Brain oxygen further decreased to 19 +/- 6 mm Hg toward the end of the experiment, 4 hours later. After middle cerebral artery occlusion, the regional cerebral blood flow decreased to 10 +/- 5 ml per 100 g per minute, within the 1st hour, from a baseline value of 65 +/- 15 ml per 100 g per minute. It then gradually increased to 15 +/- 5 ml per 100 g per minute by the end of the 4-hour experiment. Brain pH was closely and inversely related to brain CO2. The brain temperature in the focally ischemic tissue decreased from 36.7 +/- 0.7 to 35.5 +/- 1.6 degrees C by the end of the experiment. The in vitro experiment demonstrated good linear correlation between the sensor readings and the blood gas analysis. Continuous monitoring of oxygen, CO2, pH, and temperature in damaged or at-risk brain tissue using a single sensor is now feasible and will, thus, allow improved continuous monitoring of neurosurgical patients who are at risk of significant secondary brain damage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Obrist, W. D., Langfitt, T. W., Jaggi, J. L., Cruz, J., & Gennarelli, T. A. (1984) · Journal of Neurosurgery · doi:10.3171/jns.1984.61.2.0241 · Cited by 835
Circulation and Energy Metabolism of the Brain
Clarke, D. D., & Sokoloff, L. (1999) · Cited by 732
Krogh, A. (1919) · The Journal of Physiology · doi:10.1113/jphysiol.1919.sp001838 · Cited by 647
Therapeutic modulation of brain temperature: relevance to ischemic brain injury.
Ginsberg, M. D., Sternau, L., Globus, M. Y. ‐., Dietrich, W. D., & Busto, R. (1992) · PubMed · Cited by 429
Continuous monitoring of jugular venous oxygen saturation in head-injured patients
Sheinberg, M., Kanter, M. J., Robertson, C. S., Contant, C. F., Narayan, R. K., & Grossman, R. G. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.76.2.0212 · Cited by 422
Cerebral arteriovenous oxygen difference as an estimate of cerebral blood flow in comatose patients
Robertson, C. S., Narayan, R. K., Gokaslan, Z. L., Pahwa, R., Grossman, R. G., Caram, P., & Allen, E. (1989) · Journal of Neurosurgery · doi:10.3171/jns.1989.70.2.0222 · Cited by 388
Regional cerebral blood flow, intracranial pressure, and brain metabolism in comatose patients
Bruce, D. A., Langfitt, T. W., Miller, J. D., Schutz, H., Vapalahti, M. P., Stanek, A., & Goldberg, H. I. (1973) · Journal of Neurosurgery · doi:10.3171/jns.1973.38.2.0131 · Cited by 325
Die Sauerstoffdiffusion im Gehirn: Ein Beitrag zur Frage der Sauerstoffversorgung der Organe
Thews, G. (1960) · Pfl�gers Archiv f�r die Gesamte Physiologie des Menschen und der Tiere · doi:10.1007/bf00363005 · Cited by 185
Hyperthermia complicates middle cerebral artery occlusion induced by an intraluminal filament
Zhao, Q., Memezawa, H., Smith, M.-L., & Siejö, B. K. (1994) · Brain Research · doi:10.1016/0006-8993(94)91071-5 · Cited by 164
Some observations on the cerebral cortex with an ultramicro, membrane-covered, oxygen electrode
Silver, I. A. (1965) · Medical & Biological Engineering & Computing · doi:10.1007/bf02476132 · Cited by 160
Studies of Tissue PO2 in Normal and Pathological Human Brain Cortex
Meixensberger, J., Dings, J. T. A., Kuhnigk, H., & Roosen, K. (1993) · Springer eBooks · doi:10.1007/978-3-7091-9302-0_10 · Cited by 140
Specialized brain cooling in humans?
Brengelmann, G. L. (1993) · The FASEB Journal · doi:10.1096/fasebj.7.12.8375613 · Cited by 108
Regulation of local tissuePo 2of the brain cortex at different arterial O2 pressures
Leniger-Follert, E., L�bbers, D. W., & Wrabetz, W. (1975) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00581279 · Cited by 105
Hasegawa, Y., Latour, L. L., Sotak, C. H., Dardzinski, B. J., & Fisher, M. (1994) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1994.49 · Cited by 94
Cerebral Blood Flow and Metabolism
Edvinson, L., MacKenzie, E. T., & McCulloch, J. (1993) · Alzheimer Disease & Associated Disorders · doi:10.1097/00002093-199307020-00012 · Cited by 77
Functional compartmentalization of energy production in neural tissue
Andersen, B. J., & Marmarou, A. (1992) · Brain Research · doi:10.1016/0006-8993(92)91206-t · Cited by 52
Brain oxygen autoregulation: A protective reflex to hypoxia?
Bicher, H. I. (1974) · Microvascular Research · doi:10.1016/s0026-2862(74)80005-1 · Cited by 46
The evaluation of a new intravascular blood gas monitoring system in the pig
Clutton-Brock, T. H., Fink, S., Markele, D., Luthra, A. J., & Hendry, S. P. (1994) · The Journal of Clinical Monitoring · doi:10.1007/bf01618420 · Cited by 44
Ritter, A. M., & Robertson, C. S. (1994) · Neurosurgery Clinics of North America · doi:10.1016/s1042-3680(18)30491-1 · Cited by 40
Tomlinson, F. H., Anderson, R. E., & Meyer, F. B. (1993) · Stroke · doi:10.1161/01.str.24.3.435 · Cited by 39
Monitoring of Rectal, Epidural, and Intraventricular Temperature in Neurosurgical Patients
Mellergård, P. (1994) · Springer eBooks · doi:10.1007/978-3-7091-9334-1_133 · Cited by 33
Heating of the brain to maintain normothermia during ischemia aggravates brain injury in the rat
Miyazawa, T., Bonnekoh, P., Widmann, R., & Hossmann, K. (1993) · Acta Neuropathologica · doi:10.1007/bf00230487 · Cited by 32
In-Vivo Monitoring of Arterial Blood Gases and pH
Shapiro, B. A. (1992) · Respiratory Care · doi:10.1177/194336549203700207 · Cited by 16
The pathology of blunt head injury.
Simpson, K. (1949) · PubMed · Cited by 10
11 MEASURING CEREBRAL BLOOD FLOW AND METABOLISM
Zauner, A., & Muizelaar, J. P. (1997) · Cited by 9
Self-citationRegulation of Microflow in the Cat Brain During Insulin Induced Hypoglycemia
Leniger-Follert, E., Gronczewski, J., & Danz, C. (1984) · Advances in experimental medicine and biology · doi:10.1007/978-1-4684-1188-1_24 · Cited by 3
Cited by
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Keeley, T. P., & Mann, G. E. (2019) · Physiological Reviews · doi:10.1152/physrev.00041.2017 · Cited by 329
Menzel, M., Doppenberg, E. M. R., Zauner, A., Soukup, J., Reinert, M. M., & Bullock, R. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.91.1.0001 · Cited by 303
Self-citationHyperventilation in Head Injury
Stocchetti, N., Maas, A. I. R., Chieregato, A., & van der Plas, A. A. (2005) · Chest · doi:10.1378/chest.127.5.1812 · Cited by 235
Vajkoczy, P., Roth, H., Horn, P., Lucke, T., Thomé, C., Hubner, U., Martin, G. T., Zappletal, C., Klar, E., Schilling, L., et al. (2000) · Journal of Neurosurgery · doi:10.3171/jns.2000.93.2.0265 · Cited by 229
Metadata
- Authors
- Zauner, A., Bullock, R., Di, X., & Young, H. F.
- Venue
- Neurosurgery
- Published
- 1995-12-01
- Volume
- 37
- Issue
- 6
- Pages
- 1168-1177
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2047100038
- Cited by
- 162
- References
- 28
- FWCI
- 8.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.