CoChat

DEEP BRAIN STIMULATION FOR OBSESSIVE-COMPULSIVE DISORDER: USING FUNCTIONAL MAGNETIC RESONANCE IMAGING AND ELECTROPHYSIOLOGICAL TECHNIQUES TECHNICAL CASE REPORT

Baker, Kenneth B., Kopell, Brian H., Malone, Donald, Horenstein, Craig, Lowe, Mark, Phillips, Micheal D., Rezai, Ali R. · 2007 · Operative Neurosurgery
Cited by 29

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVE AND IMPORTANCE: To demonstrate the pattern of activation associated with electrical stimulation through bilateral deep brain stimulation electrodes placed within the anterior limb of the internal capsule to the level of the ventral striatum for treatment of obsessive-compulsive disorder. CLINICAL PRESENTATION: A 44-year-old man with a 26-year history of obsessive-compulsive disorder underwent functional magnetic resonance imaging (fMRI) and deep brain stimulation-evoked cortical potential testing after bilateral implantation of deep brain stimulation leads. Stimulation was delivered independently through the distal two contacts of each percutaneously extended lead using an external pulse generator. On postoperative Day 2, we used a 3-Tesla magnetic resonance system to measure changes in the fMRI blood oxygen level-dependent signal using stimulation parameters that were predetermined to demonstrate behavioral effects. INTERVENTION: All studies were well tolerated. Trial stimulations performed intraoperatively as well as on postsurgical Day 1 were associated with acutely elevated mood and reduced anxiety. Although the benefit achieved acutely was relatively symmetric between the bilaterally placed leads, follow-up programming showed a clear advantage to right-sided stimulation. Three of the four fMRI trials demonstrated good activation, with the fourth being moderately corrupted by motion artifact. The beneficial effects observed with right-sided stimulation were associated with activation of the ipsilateral head of the caudate, medial thalamus, and anterior cingulate cortex as well as the contralateral cerebellum. The distribution of the cortical evoked potentials was consistent with the locus of cortical activation observed with fMRI. CONCLUSION: High-frequency stimulation via a lead placed in the anterior limb of the internal capsule induced widespread hemodynamic changes at both the cortical and subcortical levels including areas typically associated with the pathogenesis of obsessive-compulsive disorder.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/01.neu.0000303995.66902.36

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 29

Metadata

Authors
Baker, K. B., Kopell, B. H., Malone, D., Horenstein, C., Lowe, M., Phillips, M. D., & Rezai, A. R.
Venue
Operative Neurosurgery
Published
2007-11
Volume
61
Issue
5
Pages
E367-E368
ISSN
2332-4252 (ISSN-L)
OpenAlex
W10839679
Cited by
29
References
7
FWCI
1.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: DEEP BRAIN STIMULATION FOR OBSESSIVE-COMPULSIVE DISORDER: USING FUNCTIONAL MAGNETIC RESONANCE IMAGING AND ELECTROPHYSIOLOGICAL TECHNIQUES TECHNICAL CASE REPORT. https://app.cochat.ai/papers/10.1227/01.neu.0000303995.66902.36
The paper
Baker, K. B., Kopell, B. H., Malone, D., Horenstein, C., Lowe, M., Phillips, M. D., & Rezai, A. R. (2007). DEEP BRAIN STIMULATION FOR OBSESSIVE-COMPULSIVE DISORDER: USING FUNCTIONAL MAGNETIC RESONANCE IMAGING AND ELECTROPHYSIOLOGICAL TECHNIQUES TECHNICAL CASE REPORT. Operative Neurosurgery. https://doi.org/10.1227/01.neu.0000303995.66902.36

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.