INTRACRANIAL ELECTROENCEPHALOGRAPHY WITH SUBDURAL GRID ELECTRODES: TECHNIQUES, COMPLICATIONS, AND OUTCOMES
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Intracranial subdural grid monitoring is a useful diagnostic technique for surgical localization in patients with intractable partial epilepsy. The rationale for the present study was to assess the morbidity of intracranial recordings and the surgical outcomes. METHODS: We retrospectively reviewed the clinical data for 189 unique patients undergoing 198 intracranial subdural grid monitoring sessions between 1996 and 2004 at a tertiary epilepsy center. RESULTS: The mean age of patients undergoing monitoring was 28 +/- 14 years. An average of 63 +/- 23 electrodes were inserted. The mean duration of monitoring was 8 +/- 4 days. Localization of an epileptogenic zone occurred in 156 sessions (79%) resulting in 136 resections (69%). There were 13 major complications (6.6%), including five infections and six hematomas. Three patients (1.5%) developed permanent deficits related to implantation. Sixty-two (47%) of 136 patients undergoing resection were seizure-free after resection. An additional 38 patients (28%) had a significant reduction in seizures. The mean follow-up was 51 +/- 30 months. The duration of monitoring, bone flap replacement, number of electrodes, and perioperative corticosteroids were not associated with infection or complication. CONCLUSION: Subdural grid monitoring for identification an epileptogenic focus is high yield, revealing a focus in 79% of monitoring sessions. Complications rarely result in permanent morbidity (1.5%). Surgical outcome indicated that 74% of patients experienced a favorable reduction in seizure tendency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Outcome with respect to epileptic seizures.
Engel, J. (1993) · Medical Entomology and Zoology · Cited by 2,338
Engel, J. (1996) · New England Journal of Medicine · doi:10.1056/nejm199603073341008 · Cited by 875 · cited 1×
“Neocortical 11 (46) 7 (29) 2 (8) 4 (17) 24”
Predictors of epilepsy surgery outcome: a meta-analysis
Tonini, C., Beghi, E., Berg, A. T., Bogliun, G., Giordano, L., Newton, R. W., Tetto, A., Vitelli, E., Vitezic, D., & Wiebe, S. (2004) · Epilepsy Research · doi:10.1016/j.eplepsyres.2004.08.006 · Cited by 365 · cited 2×
“Gliosis 90 40 (44) 22 (24) 9 (10) 19 (21)”
BackgroundSurgical and Neurological Complications in a Series of 708 Epilepsy Surgery Procedures
Behrens, E., Schramm, J., Zentner, J., & König, R. (1997) · Neurosurgery · doi:10.1097/00006123-199707000-00004 · Cited by 294
Complications of invasive video-EEG monitoring with subdural grid electrodes
Hamer, H. M., Morris, H. H., Mascha, E. J., Karafa, M. T., Bingaman, W. E., Bej, M. D., Burgess, R. C., Dinner, D. S., Foldvary, N. R., Hahn, J. F., et al. (2002) · Neurology · doi:10.1212/wnl.58.1.97 · Cited by 289 · cited 7×
“The use of depth electrodes has been reported as being associated with complications (11); there was no correlation in our study (P 0.”
BackgroundResultInfluentialCost of Epilepsy in the United States: A Model Based on Incidence and Prognosis
Begley, C. E., Annegers, J. F., Lairson, D. R., Reynolds, T. F., & Hauser, W. A. (1994) · Epilepsia · doi:10.1111/j.1528-1157.1994.tb01794.x · Cited by 242 · cited 2×
“Interestingly, 75% of the cost of epilepsy in the United States is accounted for by the one-fifth of patients in this group who are medically refractory (4).”
BackgroundZentner, J., Hufnagel, A., Ostertun, B., Wolf, H. K., Behrens, E., Campos, M. G., Solymosi, L., Elger, C. E., Wiestler, O. D., & Schramm, J. (1996) · Epilepsia · doi:10.1111/j.1528-1157.1996.tb01027.x · Cited by 194
Complications and results of subdural grid electrode implantation in epilepsy surgery
Lee, W.-S., Lee, J. K., Lee, S., Kang, J.-K., & Ko, T. (2000) · Surgical Neurology · doi:10.1016/s0090-3019(00)00324-4 · Cited by 122 · cited 4×
“(14) noted that of these five, three were Engel Class IV, representing a difficult population.”
BackgroundResultInfluentialUse of Subdural Grids and Strip Electrodes to Identify a Seizure Focus in Children
Adelson, D., Black, P. M., Madsen, J. R., Kramer, U., Rockoff, M. A., Riviello, J. J., Helmers, S. L., Mikati, M. A., & Holmes, G. L. (2008) · Pediatric Neurosurgery · doi:10.1159/000120898 · Cited by 97
Complications of invasive subdural electrode monitoring at St. Louis Children’s Hospital, 1994–2005
Johnston, J. M., Mangano, F. T., Ojemann, J. G., Park, T. S., Trevathan, E., & Smyth, M. D. (2006) · Journal of Neurosurgery Pediatrics · doi:10.3171/ped.2006.105.5.343 · Cited by 93 · cited 3×
“However, we noted no such correlation in our study (6, 11, 13, 14, 16, 22).”
BackgroundResult
Cited by
Cardinale, F., Cossu, M., Castana, L., Casaceli, G., Schiariti, M. P., Miserocchi, A., Fuschillo, D., Moscato, A., Caborni, C., Arnulfo, G., et al. (2013) · Neurosurgery · doi:10.1227/neu.0b013e31827d1161 · Cited by 527
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Arya, R., Mangano, F. T., Horn, P. S., Holland, K. D., Rose, D. F., & Glauser, T. A. (2013) · Epilepsia · doi:10.1111/epi.12073 · Cited by 221
Recording and analysis techniques for high-frequency oscillations
Worrell, G. A., Jerbi, K., Kobayashi, K., Lina, J. M., Zelmann, R., & Le Van Quyen, M. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.02.006 · Cited by 196
“Fortunately, the technical challenges of data transfer, storage, and analysis of large Terabyte data sets is now possible (Le Van Quyen and Bragin, 2007; Brinkmann et al., 2009).”
InfluentialSelf-citationTandon, N., Tong, B. A., Friedman, E. R., Johnson, J. A., Von Allmen, G., Thomas, M. S., Hope, O. A., Kalamangalam, G. P., Slater, J. D., & Thompson, S. A. (2019) · JAMA Neurology · doi:10.1001/jamaneurol.2019.0098 · Cited by 191
Kourbeti, I. S., Vakis, A. F., Ziakas, P., Karabetsos, D., Potolidis, E., Christou, S., & Samonis, G. (2015) · Journal of Neurosurgery · doi:10.3171/2014.8.jns132557 · Cited by 187
Risks and benefits of invasive epilepsy surgery workup with implanted subdural and depth electrodes
Wellmer, J., von der Groeben, F., Klarmann, U., Weber, C., Elger, C. E., Urbach, H., Clusmann, H., & von Lehe, M. (2012) · Epilepsia · doi:10.1111/j.1528-1167.2012.03545.x · Cited by 169
“This result is similar to those of other studies that report implantation-associated risks (Behrens et al., 1997; Hamer et al., 2002; Cossu et al., 2005; Burneo et al., 2006; Fountas & Smith, 2007; Van Gompel et al., 2008; Tanriverdi et al., 2009; Wong et al., 2009).”
BackgroundResultInfluential(2016) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-53486-6.00051-x · Cited by 169
“Surgical outcome has indicated that 74% of patients experienced a favorable reduction in seizure tendency (Van Gompel et al., 2008).”
BackgroundTowards Large-Scale, Human-Based, Mesoscopic Neurotechnologies
Chang, E. F. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.037 · Cited by 163
“…out following craniotomy by placing thin electrode subdural arrays, called ‘‘grids,’’ on the exposed brain surface below the dura, and often supplemented by gently sliding additional electrode strips under the dura to unexposed cortical surfaces(Fountas and Smith, 2007; Van Gompel et al., 2008).”
Background
Metadata
- Authors
- Van Gompel, J. J., Worrell, G. A., Bell, M. L., Patrick, T. A., Cascino, G. D., Raffel, C., Marsh, W. R., & Meyer, F. B.
- Venue
- Neurosurgery
- Published
- 2008-09
- Volume
- 63
- Issue
- 3
- Pages
- 498-506
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W1996886729
- Cited by
- 158
- References
- 16
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.