Flow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Although the introduction of flow-diverter devices (FDDs) has aroused great enthusiasm, the level of evidence supporting their use has not been systematically evaluated. OBJECTIVE: To report a systematic review of medical literature up to May 2012 on FDDs to assess the morbidity, case fatality rate, and efficacy of FDDs for intracranial aneurysms. METHODS: The literature was searched by using MEDLINE, Embase, and all Evidence-Based Medicine in the OVID database. Eligibility criteria were studies including at least 10 patients, reporting duration of follow-up and number of patients lost to follow-up, and documenting the rate of aneurysm occlusion and death and neurological complications. The endpoints were angiographic success, early and late mortality, and neurological morbidity. RESULTS: Fifteen studies were analyzed consisting of 897 patients with 1018 aneurysms. The mean value of methodological quality score was 14.4 using the STROBE score. The early mortality rate was 2.8% (95% confidence interval [CI]: 1.7-3.8; I(2) = 93.4%) and the late mortality rate was 1.3% (95% CI: 0.2-2.3; I(2) = 36.9%). The early neurological morbidity rate was 7.3% (95% CI: 5.7-9; I(2) = 91.8%) and the late morbidity rate was 2.6% (95% CI: 1.1-4; I(2) = 81.3%). The Egger test for early and late morbidity and aneurysm occlusion was <0.001. CONCLUSION: With the available data from the studies, both heterogeneity and publication biases imply that the current clinical use of FDDs is not supported by high-quality evidence. In the absence of reliable evidence, the use of FDDs in patients eligible for more conventional treatments should be restricted to controlled clinical trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763 · cited 1×
“The heterogeneity between studies was assessed by the Q test and the calculation of I2, which can be interpreted as the percentage of the total variability in a set of effect sizes due to true heterogeneity, that is, between-studies variability.(16,17) We assessed publication bias by using funnel plots, representing t…”
Methodvon Elm, E., Altman, D. G., Egger, M., Pocock, S. J., Gøtzsche, P. C., & Vandenbroucke, J. P. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61602-x · Cited by 21,320
Meta-analysis of Observational Studies in Epidemiology<SUBTITLE>A Proposal for Reporting</SUBTITLE>
Stroup, D. F. (2000) · JAMA · doi:10.1001/jama.283.15.2008 · Cited by 20,623
Wiebers, D. O. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13860-3 · Cited by 3,905
Molyneux, A. J., Kerr, R. S., Yu, L.-M., Clarke, M., Sneade, M., Yarnold, J. A., & Sandercock, P. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67214-5 · Cited by 2,886
What to add to nothing? Use and avoidance of continuity corrections in meta‐analysis of sparse data
J. Sweeting, M., J. Sutton, A., & C. Lambert, P. (2004) · Statistics in Medicine · doi:10.1002/sim.1761 · Cited by 1,734 · cited 1×
“We applied a correction procedure to studies with zero outcomes by adding to both the numerator and denominator the result fromdividing the number of patients of the study by the total studies to be pooled.(15) The heterogeneity between studies was assessed by the Q test and the calculation of I2, which can be interpr…”
MethodGuglielmi, G., Viñuela, F., Sepetka, I., & Macellari, V. (1991) · Journal of Neurosurgery · doi:10.3171/jns.1991.75.1.0001 · Cited by 1,260
Balloon catheterization and occlusion of major cerebral vessels
Serbinenko, F. A. (1974) · Journal of Neurosurgery · doi:10.3171/jns.1974.41.2.0125 · Cited by 955
The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial
Nelson, P. K., Lylyk, P., Szikora, I., Wetzel, S. G., Wanke, I., & Fiorella, D. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2421 · Cited by 843 · cited 1×
“In this setting, flow-diverter devices (FDDs) have emerged as a new generation of endoluminal implants that are designed to treat aneurysms by reconstructing the diseased parent artery.(9) Its design focuses on diverting flow from the aneurysm and thus creating an environment prone to its thrombosis.”
BackgroundThe Barrow Ruptured Aneurysm Trial: Clinical article
McDougall, C. G., Spetzler, R. F., Zabramski, J. M., Partovi, S., Hills, N. K., Nakaji, P., & Albuquerque, F. C. (2012) · Journal of Neurosurgery · doi:10.3171/2011.8.jns101767 · Cited by 647
Bederson, J. B., Awad, I. A., Wiebers, D. O., Piepgras, D., Haley, E. C., Brott, T., Hademenos, G., Chyatte, D., Rosenwasser, R., & Caroselli, C. (2000) · Stroke · doi:10.1161/01.str.31.11.2742 · Cited by 419
Fischer, S., Vajda, Z., Aguilar Perez, M., Schmid, E., Hopf, N., Bäzner, H., & Henkes, H. (2012) · Neuroradiology · doi:10.1007/s00234-011-0948-x · Cited by 393
Naggara, O. N., White, P. M., Guilbert, F., Roy, D., Weill, A., & Raymond, J. (2010) · Radiology · doi:10.1148/radiol.10091982 · Cited by 304 · cited 1×
“Regarding our review, the results of treatment with FDDs are worse than those reported in some clipping or coiling series.(41-44) However, these results can be biased if FDDs have been used in more difficult cases in which standard treatments have been ruled out.”
ResultTurowski, B., Macht, S., Kulcsár, Z., Hänggi, D., & Stummer, W. (2011) · Neuroradiology · doi:10.1007/s00234-010-0676-7 · Cited by 227
Komotar, R. J., Mocco, J., & Solomon, R. A. (2008) · Neurosurgery · doi:10.1227/01.neu.0000311076.64109.2e · Cited by 166
CONTROVERSIES IN THE SURGICAL TREATMENT OF RUPTURED INTRACRANIAL ANEURYSMS
Komotar, R. J., Zacharia, B. E., Mocco, J., & Connolly, E. S. (2008) · Neurosurgery · doi:10.1227/01.neu.0000316006.26635.b0 · Cited by 158
Qureshi, A. I., Janardhan, V., Hanel, R. A., & Lanzino, G. S. (2007) · The Lancet Neurology · doi:10.1016/s1474-4422(07)70217-x · Cited by 90
Cited by
Becske, T., Brinjikji, W., Potts, M. B., Kallmes, D. F., Shapiro, M., Moran, C. J., Levy, E. I., McDougall, C. G., Szikora, I., Lanzino, G., et al. (2017) · Neurosurgery · doi:10.1093/neuros/nyw014 · Cited by 447
Aneurysmal Subarachnoid Hemorrhage
D’Souza, S. (2015) · Journal of Neurosurgical Anesthesiology · doi:10.1097/ana.0000000000000130 · Cited by 294
Kallmes, D. F., Brinjikji, W., Cekirge, S., Fiorella, D., Hanel, R. A., Jabbour, P., Lopes, D., Lylyk, P., McDougall, C. G., & Siddiqui, A. (2017) · Journal of Neurosurgery · doi:10.3171/2016.8.jns16467 · Cited by 249
Aneurysm Study of Pipeline in an Observational Registry (ASPIRe)
Kallmes, D. F., Brinjikji, W., Boccardi, E., Ciceri, E., Diaz, O., Tawk, R., Woo, H., Jabbour, P., Albuquerque, F., Chapot, R., et al. (2016) · Interventional Neurology · doi:10.1159/000446503 · Cited by 210
Case-control studies in neurosurgery: A review
Nesvick, C. L., Thompson, C. J., Boop, F. A., & Klimo, P. (2014) · Journal of Neurosurgery · doi:10.3171/2014.5.jns132329 · Cited by 22
Metadata
- Authors
- Arrese, I., Sarabia, R., Pintado, R., & Delgado-Rodriguez, M.
- Venue
- Neurosurgery
- Published
- 2013-08
- Volume
- 73
- Issue
- 2
- Pages
- 193-200
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W1980984708
- Cited by
- 171
- References
- 21
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.