Virtual Reality Cerebral Aneurysm Clipping Simulation With Real-Time Haptic Feedback
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
BACKGROUND: With the decrease in the number of cerebral aneurysms treated surgically and the increase of complexity of those treated surgically, there is a need for simulation-based tools to teach future neurosurgeons the operative techniques of aneurysm clipping. OBJECTIVE: To develop and evaluate the usefulness of a new haptic-based virtual reality simulator in the training of neurosurgical residents. METHODS: A real-time sensory haptic feedback virtual reality aneurysm clipping simulator was developed using the ImmersiveTouch platform. A prototype middle cerebral artery aneurysm simulation was created from a computed tomographic angiogram. Aneurysm and vessel volume deformation and haptic feedback are provided in a 3-dimensional immersive virtual reality environment. Intraoperative aneurysm rupture was also simulated. Seventeen neurosurgery residents from 3 residency programs tested the simulator and provided feedback on its usefulness and resemblance to real aneurysm clipping surgery. RESULTS: Residents thought that the simulation would be useful in preparing for real-life surgery. About two-thirds of the residents thought that the 3-dimensional immersive anatomic details provided a close resemblance to real operative anatomy and accurate guidance for deciding surgical approaches. They thought the simulation was useful for preoperative surgical rehearsal and neurosurgical training. A third of the residents thought that the technology in its current form provided realistic haptic feedback for aneurysm surgery. CONCLUSION: Neurosurgical residents thought that the novel immersive VR simulator is helpful in their training, especially because they do not get a chance to perform aneurysm clippings until late in their residency programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Additive fabrication technologies applied to medicine and health care: a review
Giannatsis, J., & Dedoussis, V. (2009) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-007-1308-1 · Cited by 389 · cited 1×
“The physical models are created by a variety of additive fabrication and rapid prototyping technologies, including stereolithography and 3-D printing.(31,32) The earliest biomodels by D’Urso et al(33) and Wurm et al(34) used 3-D CTA or MRA with stereolithography to produce nondeformable solid replicas of aneurysms and…”
MethodA review of rapid prototyping (RP) techniques in the medical and biomedical sector
Webb, P. A. (2000) · Journal of Medical Engineering & Technology · doi:10.1080/03091900050163427 · Cited by 276 · cited 1×
“The physical models are created by a variety of additive fabrication and rapid prototyping technologies, including stereolithography and 3-D printing.(31,32) The earliest biomodels by D’Urso et al(33) and Wurm et al(34) used 3-D CTA or MRA with stereolithography to produce nondeformable solid replicas of aneurysms and…”
MethodPlanning and Simulation of Neurosurgery in a Virtual Reality Environment
Kockro, R. A., Serra, L., Tseng-Tsai, Y., Chan, C., Yih-Yian, S., Guan, C. G., Lee, E., Hoe, L. Y., Hern, N., & Nowinski, W. L. (2000) · Neurosurgery · doi:10.1093/neurosurgery/46.1.118 · Cited by 229
Mashiko, T., Otani, K., Kawano, R., Konno, T., Kaneko, N., Ito, Y., & Watanabe, E. (2015) · World Neurosurgery · doi:10.1016/j.wneu.2013.10.032 · Cited by 228
Lemole, G. M., Banerjee, P. P., Luciano, C., Neckrysh, S., & Charbel, F. T. (2007) · Neurosurgery · doi:10.1227/01.neu.0000279734.22931.21 · Cited by 205
Self-citationVirtual reality training in neurosurgery: Review of current status and future applications
Alaraj, A., Lemole, M., Finkle, J., Yudkowsky, R., Wallace, A., Luciano, C., Banerjee, P., Rizzi, S., & Charbel, F. (2011) · Surgical Neurology International · doi:10.4103/2152-7806.80117 · Cited by 204 · cited 1×
“These include ventriculostomy, which has been validated,(7,9-11) positively reviewed,(12) and independently tested,(2) bone drilling,(8) spinal procedures such as pedicle screw placement,(13,14) vertebroplasty, and lumbar puncture, trigeminal rhizotomy,(8) and other procedures.(15,16) These modules are currently used…”
BackgroundSelf-citationMalone, H. R., Syed, O. N., Downes, M. S., D'Ambrosio, A. L., Quest, D. O., & Kaiser, M. G. (2010) · Neurosurgery · doi:10.1227/neu.0b013e3181ee46d0 · Cited by 171
Alaraj, A. M., Charbel, F. T., Birk, D. M., Tobin, M., Luciano, C., Banerjee, P. P., Rizzi, S., Sorenson, J., Foley, K. T., Slavin, K. V., et al. (2012) · Neurosurgery · doi:10.1227/neu.0b013e3182753093 · Cited by 149
Self-citationAdvanced 3-Dimensional Planning in Neurosurgery
Ferroli, P., Tringali, G., Acerbi, F., Schiariti, M. P., Broggi, M. A., Aquino, D., & Broggi, G. (2012) · Neurosurgery · doi:10.1227/neu.0b013e3182748ee8 · Cited by 135
Yudkowsky, R., Luciano, C., Banerjee, P. P., Schwartz, A., Alaraj, A. M., Lemole, G. M., Charbel, F. T., Smith, K. M., Rizzi, S., Byrne, R. W., et al. (2013) · Simulation in Healthcare The Journal of the Society for Simulation in Healthcare · doi:10.1097/sih.0b013e3182662c69 · Cited by 130
Self-citationGnanalingham, K. K., Apostolopoulos, V., Barazi, S. A., & O’Neill, K. (2005) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2005.11.001 · Cited by 125 · cited 1×
“Training in aneurysm clipping became more complicated with the drastic drop in the number of aneurysms being treated surgically: technically easier aneurysms and most unruptured aneurysms are being treated with endovascular means (stentassisted coiling or flow diverting stents).(6) Yet these difficult cases of clippin…”
BackgroundBanerjee, P. P., Luciano, C., Lemole, G. M., Charbel, F. T., & Oh, M. Y. (2007) · Journal of neurosurgery · doi:10.3171/jns-07/09/0515 · Cited by 119
Self-citationCerebrovascular Biomodeling for Aneurysm Surgery
Wurm, G., Lehner, M., Tomancok, B., Kleiser, R., & Nußbaumer, K. (2011) · Surgical Innovation · doi:10.1177/1553350610395031 · Cited by 106
Assessing performance in brain tumor resection using a novel virtual reality simulator
Gélinas-Phaneuf, N., Choudhury, N., Al-Habib, A. R., Cabral, A., Nadeau, E., Mora, V., Pazos, V., Debergue, P., DiRaddo, R. W., & Maestro, R. F. D. (2013) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-013-0905-8 · Cited by 86 · cited 3×
“Currently there is no fully immersive haptics-based virtual reality aneurysm simulation besides the ITACS.(39) Recently the Selman Surgical Rehearsal Platform (SSRP) produced by Surgical Theater, LLC (Cleveland, Ohio), was introduced with particular reference to patient-specific aneurysm clipping.”
MethodInfluentialVirtual Reality–Based Simulation Training for Ventriculostomy
Schirmer, C. M., Elder, J. B., Roitberg, B. Z., & Lobel, D. A. (2013) · Neurosurgery · doi:10.1227/neu.0000000000000074 · Cited by 78
Self-citationPercutaneous Spinal Fixation Simulation With Virtual Reality and Haptics
Luciano, C., Banerjee, P. P., Sorenson, J. M., Foley, K. T., Ansari, S. A., Rizzi, S., Germanwala, A. V., KRANZLER, L. I., Chittiboina, P., & Roitberg, B. Z. (2012) · Neurosurgery · doi:10.1227/neu.0b013e3182750a8d · Cited by 75
Self-citationEvolving Virtual Reality Simulation in Neurosurgery
Schirmer, C. M., Mocco, J., & Elder, J. B. (2013) · Neurosurgery · doi:10.1227/neu.0000000000000060 · Cited by 45
Gasco, J., Patel, A. P., Luciano, C., Holbrook, T. J., Ortega-Barnett, J. R., Kuo, Y., Rizzi, S., Kania, P., Banerjee, P. P., & Roitberg, B. Z. (2013) · World Neurosurgery · doi:10.1016/j.wneu.2013.09.040 · Cited by 22 · cited 2×
“These include ventriculostomy, which has been validated,(7,9-11) positively reviewed,(12) and independently tested,(2) bone drilling,(8) spinal procedures such as pedicle screw placement,(13,14) vertebroplasty, and lumbar puncture, trigeminal rhizotomy,(8) and other procedures.(15,16) These modules are currently used…”
BackgroundSelf-citation
Cited by
Systematic review on the effectiveness of augmented reality applications in medical training
Barsom, E. Z., Graafland, M., & Schijven, M. P. (2016) · Surgical Endoscopy · doi:10.1007/s00464-016-4800-6 · Cited by 666
Metaverse for Healthcare: A Survey on Potential Applications, Challenges and Future Directions
Chengoden, R., Victor, N., Huynh-The, T., Yenduri, G., Jhaveri, R. H., Alazab, M., Bhattacharya, S., Hegde, P., Maddikunta, P. K. R., & Gadekallu, T. R. (2023) · IEEE Access · doi:10.1109/access.2023.3241628 · Cited by 508
The potential of immersive virtual reality to enhance learning: A meta-analysis
Coban, M., Bolat, Y. I., & Goksu, I. (2022) · Educational Research Review · doi:10.1016/j.edurev.2022.100452 · Cited by 354
Utilizing virtual and augmented reality for educational and clinical enhancements in neurosurgery
Pelargos, P. E., Nagasawa, D. T., Lagman, C., Tenn, S., Demos, J. V., Lee, S. J., Bui, T. T., Barnette, N. E., Bhatt, N. S., Ung, N., et al. (2017) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2016.09.002 · Cited by 298
Virtual Reality and Augmented Reality in Plastic Surgery: A Review
Kim, Y., Kim, H., & Kim, Y. O. (2017) · Archives of Plastic Surgery · doi:10.5999/aps.2017.44.3.179 · Cited by 267
Metadata
- Authors
- Alaraj, A., Luciano, C. J., Bailey, D. P., Elsenousi, A., Roitberg, B. Z., Bernardo, A., Banerjee, P. P., & Charbel, F. T.
- Venue
- Operative Neurosurgery
- Published
- 2015-03
- Volume
- 11
- Issue
- 1
- Pages
- 52-58
- ISSN
- 2332-4252 (ISSN-L)
- OpenAlex
- W2329607943
- Cited by
- 185
- References
- 18
- FWCI
- 17.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.